The primary water source for cooling the condenser of a water-cooled recovery unit is: - local municipal water supply Which of the foloowing repairs would ALWAYS be considered "major" under EPA's - replacement of evaporator coil According to ASHRAE Guideline 3-1996, if the pressure in a system rises from 1 mm Hg to a level above ____ during a standing vacuum test, the system should be checked for leaks. - 2.5 mm Hg On low pressure chillers, moisture typically enters the refrigerant system through - air leaks from areas with gaskets or fittings The maximum test pressure for leak testing a low pressure centrifugal is: - 10 psig Leak test and repair the chiller to reduce refrigerant loss from a pruge unit on CFC-11 chiller - ... A hydrostatic tube test kit is used to: - determine if a tube leaks Commercial and industrial process refrigeration systems must be repaired when the leak rate exceeds ____ of the charge per year. - 35% Refrigerant recovery typically start with liquid recovery it is faster. - ... A rupture disc on a recovery vessel for a low pressure refrigerants relieves at: - 15 psig The primary water source for a recovery unit condensing coil is _____. - local municipal water supplyWhen recharging a refrigeration system with R-11, what vaporpressure is necessary in the shells before changing with liquid? - 16.9" Hg vacuum After recovering the liquid refrigerant you must: - recover the vapor refrigerant

Content preview

EPA 608 Type 3
The primary water source for cooling the condenser of a water-cooled recovery unit is: - local
municipal water supply



Which of the foloowing repairs would ALWAYS be considered "major" under EPA's - replacement
of evaporator coil



According to ASHRAE Guideline 3-1996, if the pressure in a system rises from 1 mm Hg to a level above
____ during a standing vacuum test, the system should be checked for leaks. - 2.5 mm Hg



On low pressure chillers, moisture typically enters the refrigerant system through - air leaks from
areas with gaskets or fittings



The maximum test pressure for leak testing a low pressure centrifugal is: - 10 psig



Leak test and repair the chiller to reduce refrigerant loss from a pruge unit on CFC-11 chiller - ...



A hydrostatic tube test kit is used to: - determine if a tube leaks



Commercial and industrial process refrigeration systems must be repaired when the leak rate exceeds
____ of the charge per year. - 35%



Refrigerant recovery typically start with liquid recovery it is faster. - ...



A rupture disc on a recovery vessel for a low pressure refrigerants relieves at: - 15 psig



The primary water source for a recovery unit condensing coil is _____. - local municipal water
supply

, When recharging a refrigeration system with R-11, what vaporpressure is necessary in the shells before
changing with liquid? - 16.9" Hg vacuum



After recovering the liquid refrigerant you must: - recover the vapor refrigerant



According to the EPA there is approximately _____ refrigerant vapor left in an average 350 ton R-11
chiller at 0 psig pressure once all the R-11 liquid has been removed. - 100 pounds



Charging refrigerant liquid into a refrigeration system when it is under a 29 inch Hg vacuum can cause
the: - system water to freeze



A system does not have to be evacuated all the way to the required level when: - leaks in the
appliance make evacuation to the prescribed level unattainable



Under EPA's regulation's _______ is used to pressurize a low pressure chiller for the purpose of opening
the system for a non major repair? - warming the refrigerant



If you are using a recovery machine manufactored AFTER 11-15-93 you must evacuate an low pressure
appliance to _______ before making a major repair. - 25 mm of Hg absolute



After reaching the required recovery vacuum on a chiller, you should - Wait for at least a few
minutes to see if the system pressure rises, indicating that there is till refrigerant in a liquid form or in
the oil



The pressure corresponding to 32 F for R-123 - 20 inches of HG vacuum



When evacuating a system the use of too large a vacuum pump can cause? - trapped water to
freeze



Refrigerant-11 at a pressure of 17 inches HG vacuum has a saturation temperature of: - 35F

Document information

Uploaded on
August 26, 2024
Number of pages
13
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$8.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Sold
622
Followers
185
Items
10510
Last sold
1 month ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions