RESIDENTIAL ELECTRICIAN FINAL EXAM REVIEWS

Document preview thumbnail
Preview 2 out of 8 pages

RESIDENTIAL ELECTRICIAN FINAL EXAM REVIEWS Ferrous metal enclosures for grounding electrode conductors shall be _____. a) electrically continuous b) electrically isolated c) not permitted d) rigid metal conduit (RMC) only - CORRECT ANSWER-A: electrically continuous Ref: 250.64(E) Unless listed for the control of other loads, general use dimmer switches shall only be used to control _____. a) switched receptacles for cord-connected incandescent luminaires b) permanently installed incandescent luminaires c) ceiling fans with luminaires d) holiday decorative lighting - CORRECT ANSWER-B: permanently installed incandescent luminaires Ref: 404.14(E) All 125-volt, single-phase, 15- and 20-ampere receptacles installed in residential garages shall be _____. I) protected by a listed arc-fault interrupter II) provided with ground-fault circuit-interrupter protection a) I only b) II only c) both I and II d) neither I nor II - CORRECT ANSWER-B: II only Ref: 210.8(A)(2); 210.12(B) The MAXIMUM allowable ampacity of size 18 AWG fixture wire is _____ amperes. a) 12 b) 10 c) 8 d) 6 - CORRECT ANSWER-D: 6 Ref: Tbl. 402.5 A receptacle outlet installed for a gas or electric clothes dryer in the laundry room of a dwelling unit must be installed within at LEAST _____ feet of the intended location of the dryer. a) 6 b) 4 c) 10 d) 3 - CORRECT ANSWER-A: 6 Ref: 210.50(C) Which of the following listed conductors are required to have overcurrent protection on a residential electric service? a) grounding conductors b) bonding conductors c) identified conductors d) ungrounded conductors - CORRECT ANSWER-D: ungrounded conductors Ref: 290.9 Given: a 40-gallon electric water heater has a nameplate rating of 4,500 watts at 240 volts. What is the MAXIMUM standard size circuit breaker the NEC permits to protect the water heater? a) 20 amperes b) 25 amperes c) 30 amperes d) 45 amperes - CORRECT ANSWER-C: 30 amperes Ref: 422.11(E)(3); 240.6(A); Current Formula Sol: I = P/E I = 4500 va / 240 volts I = 18.75 amps x 150 percent I = 28.1 amperes If a cable or raceway enters an enclosure such as a meter base, above uninsulated live parts in a wet location, the fittings used to connect the enclosure must be _____ for wet locations. a) identified b) marked c) suitable d) listed - CORRECT ANSWER-D: listed Ref: 312.2(A) In general, the power supply cord to a mobile home shall have a MAXIMUM rating of _____. a) 50 amperes b) 60 amperes c) 100 amperes d) 125 amperes - CORRECT ANSWER-A: 50 amperes Ref: 550.10(A) A 150 kVA, single-phase transformer having a secondary voltage of 120/240 is to be installed at a multi-family dwelling. The current available at the secondary is _____ amperes. a) 329 b) 421 c) 625 d) 729 - CORRECT ANSWER-C: 625 Sol: I = P/E I = 150,000 va / 240 volts

Content preview

RESIDENTIAL ELECTRICIAN FINAL
EXAM REVIEWS




Ferrous metal enclosures for grounding electrode conductors
shall be _____.
a) electrically continuous
b) electrically isolated
c) not permitted
d) rigid metal conduit (RMC) only - CORRECT ANSWER-A:
electrically continuous
Ref: 250.64(E)

Unless listed for the control of other loads, general use dimmer
switches shall only be used to control _____.
a) switched receptacles for cord-connected incandescent
luminaires
b) permanently installed incandescent luminaires
c) ceiling fans with luminaires
d) holiday decorative lighting - CORRECT ANSWER-B:
permanently installed incandescent luminaires
Ref: 404.14(E)

All 125-volt, single-phase, 15- and 20-ampere receptacles
installed in residential garages shall be _____.
I) protected by a listed arc-fault interrupter
II) provided with ground-fault circuit-interrupter protection

, a) I only
b) II only
c) both I and II
d) neither I nor II - CORRECT ANSWER-B: II only
Ref: 210.8(A)(2); 210.12(B)

The MAXIMUM allowable ampacity of size 18 AWG fixture wire
is _____ amperes.
a) 12
b) 10
c) 8
d) 6 - CORRECT ANSWER-D: 6
Ref: Tbl. 402.5

A receptacle outlet installed for a gas or electric clothes dryer in
the laundry room of a dwelling unit must be installed within at
LEAST _____ feet of the intended location of the dryer.
a) 6
b) 4
c) 10
d) 3 - CORRECT ANSWER-A: 6
Ref: 210.50(C)

Which of the following listed conductors are required to have
overcurrent protection on a residential electric service?
a) grounding conductors
b) bonding conductors
c) identified conductors
d) ungrounded conductors - CORRECT ANSWER-D:
ungrounded conductors
Ref: 290.9

Given: a 40-gallon electric water heater has a nameplate rating
of 4,500 watts at 240 volts. What is the MAXIMUM standard
size circuit breaker the NEC permits to protect the water
heater?
a) 20 amperes

Document information

Uploaded on
August 15, 2024
Number of pages
8
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$10.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Sold
12
Followers
8
Items
1377
Last sold
6 months ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions