RESIDENTIAL WIREMAN ELECTRICAL EXAM REVIEWS The minimum size equipment grounding conductor for a 100 ampere, 120/240 volt single phase underground dwelling feeder whose ungrounded conductors have been increased in size from 3 AWG copper to 1 AWG copper is __ AWG copper Ampacities, Grounding 250.122(B) Table 250.122 Table 8 Ch 9 - CORRECT ANSWER-4 The continuity of the grounded conductor shall depend on a busbar or __ only. Continuity, Grounded conductors 200.12 - CORRECT ANSWER-wire. Each multi-wire branch circuit shall be provided with a means that will ____ disconnect all ungrounded conductors at the point where the branch circuit originates. Disconnecting means, Branch circuits, multiwire 210.4(B) - CORRECT ANSWER-Simultaneously Balconies, decks, and porches that are accessible from the inside of the dwelling unit shall have at least one receptacle not more than __ ft. above the balcony, deck, or porch surface. Balconies, outdoor, receptacles for, 210.52(E)(3) - CORRECT ANSWER-6 1/2 Where it is impracticable to locate the service head above the point of attachment, the service head location shall be permitted not farther than ___ inches from the point of attachment. Service drops, Connections, service head 230.54 (C) Exception - CORRECT ANSWER-24 True/False: One of the means by which grounding conductors and bonding jumpers shall NOT be connected by is machine screw type fasteners. Connection of Grounding and Bonding Equipment 250.8 - CORRECT ANSWER-False Cables with entirely nonmetallic sheaths are permitted to enter the top of a surface-mounted enclosure through one or more nonflexible raceways not less than 450 mm (18 in.) and not more than __ feet in length Cabinets, Cutout Boxes, and Meter Socket Enclosures. 312.5(C) - CORRECT ANSWER-10 The maximum allowable overcurrent protection for four 14/2 NM cables installed in contact with thermal insulation without maintaining spacing between cables is: Nonmetallic-sheathed cable, Insulation, Ampacity, 334.112, 334.80 - CORRECT ANSWER-15 What kind of protection is required for an outdoor receptacle located under the soffit of a dwelling for holiday lighting? Ground-fault circuit interrupters, Outdoors, dwelling units, 210.8(A)(3) - CORRECT ANSWER-GFCI The minimum rating for a service disconnecting means for a building, other than a single family dwelling, consisting of three 2 wire circuits shall be__ amperes. Service equipment, Rating, 230.79(D) - CORRECT ANSWER-60 Where ungrounded conductors are increased in size, equipment grounding conductors shall be increased in size ___. Grounding conductors, 250-III, Sizes, 250.122 250.122(B) - CORRECT ANSWER-proportionately True/ False: Unless listed for the control of other loads, general use dimmer switches, shall only be used to control permanently installed incandescent luminaires. Dimmers, Switch 404.14(E) - CORRECT ANSWER-True In what areas of a dwelling shall 125-volt, single phase, 15 and 20 ampere outlets not be required to be protected by an arcfault circuit interupter? Dwellings, Arc-fault circuit-interrupter protection, 210.12(A) 210.12(A) - CORRECT ANSWERHallways A ground ring encircling the building or structure, in direct contact with the earth, shall consist of at least 20 feet of bare copper conductor NOT smaller than __ AWG. Ground ring 250.52(A)(4) - CORRECT ANSWER-2

Content preview

RESIDENTIAL WIREMAN ELECTRICAL
EXAM REVIEWS




The minimum size equipment grounding conductor for a 100
ampere, 120/240 volt single phase underground dwelling
feeder whose ungrounded conductors have been increased in
size from 3 AWG copper to 1 AWG copper is __ AWG copper

Ampacities, Grounding
250.122(B) Table 250.122 Table 8 Ch 9 - CORRECT
ANSWER-4

The continuity of the grounded conductor shall depend on a
busbar or __ only.

Continuity, Grounded conductors
200.12 - CORRECT ANSWER-wire.

Each multi-wire branch circuit shall be provided with a means
that will ____ disconnect all ungrounded conductors at the point
where the branch circuit originates.

Disconnecting means, Branch circuits, multiwire 210.4(B) -
CORRECT ANSWER-Simultaneously

, Balconies, decks, and porches that are accessible from the
inside of the dwelling unit shall have at least one receptacle not
more than __ ft. above the balcony, deck, or porch surface.
Balconies, outdoor, receptacles for,
210.52(E)(3) - CORRECT ANSWER-6 1/2

Where it is impracticable to locate the service head above the
point of attachment, the service head location shall be
permitted not farther than ___ inches from the point of
attachment.
Service drops, Connections, service head
230.54 (C) Exception - CORRECT ANSWER-24

True/False: One of the means by which grounding conductors
and bonding jumpers shall NOT be connected by is machine
screw type fasteners.

Connection of Grounding and Bonding Equipment 250.8 -
CORRECT ANSWER-False

Cables with entirely nonmetallic sheaths are permitted to enter
the top of a surface-mounted enclosure through one or more
nonflexible raceways not less than 450 mm (18 in.) and not
more than __ feet in length

Cabinets, Cutout Boxes, and Meter Socket Enclosures.
312.5(C) - CORRECT ANSWER-10

The maximum allowable overcurrent protection for four 14/2
NM cables installed in contact with thermal insulation without
maintaining spacing between cables is:

Nonmetallic-sheathed cable, Insulation, Ampacity,
334.112, 334.80 - CORRECT ANSWER-15

What kind of protection is required for an outdoor receptacle
located under the soffit of a dwelling for holiday lighting?

Document information

Uploaded on
August 15, 2024
Number of pages
5
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$10.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Sold
12
Followers
8
Items
1377
Last sold
6 months ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions