Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 2 out of 15 pages
Exam (elaborations)

RESIDENTIAL WIREMAN TEST PART EXAMS AND ANSWERS

Document preview thumbnail
Preview 2 out of 15 pages

RESIDENTIAL WIREMAN TEST PART EXAMS AND ANSWERS The National Electrical Code not intended as ________. - CORRECT ANSWER-design specification or as an instrucion manual The provisions of the national electrical code are considered necessary for ________. - CORRECT ANSWER-safety What is not covered within the scope of the national electrical code? - CORRECT ANSWER-installation in underground mines Which chapter of the national electrical code covers communications systems? - CORRECT ANSWER-chapter 8 The informational annexes of the national electrical code are for ______. - CORRECT ANSWER-informational purposes only If the current edition of the national electrical code requires the use of a new product but that product is not yet available then the _____ may permit the use of a product from the most recent previous edition. - CORRECT ANSWER-authority having jurisdiction A rule that identifies actions that are allowed but not required is ______. - CORRECT ANSWER-Permissive It is not necessary to inspect a piece of equipment that has not been altered or damaged and has been listed by a qualified electrical testing laboratory is the be installed in a structure - CORRECT ANSWER-True Distribution centers located in readily accessible locations provide _______. - CORRECT ANSWER-Convenience and safety of operation Limits on the number of circuits in a single enclosure minimize the effects from a _______. - CORRECT ANSWER-Ground fault or short circuit Where units of measurement are used in the national electrical code they are given in _______ units. - CORRECT ANSWERInch-pound and/or SI When a hard conversion is made the ________ may change. - CORRECT ANSWER-dimensions Accessible as applied to equipment means admitting close approach and not guarded by _____. - CORRECT ANSWERelevation, locked doors, or other affective means. The ampacity is the maximum current, in ampheres, that a conductor can carry continuously under the conditions of use without exceeding its ______ rating. - CORRECT ANSWERTemperature An arc-fault circuit interrupter, or AFCI is a device which provides protection from the effects of arc faults by _______. - CORRECT ANSWER-recognizing characteristics unique to arcing and functioning to de-energize the circuit when an arc fault is detected Askarel is a ______ term for a group of non-flammable synthetic chlorinated hydrocarbons used as electrical insulating media - CORRECT ANSWER-generic Bonding means connected to establish electrical ______. - CORRECT ANSWER-conductivity and continuity A bonding jumper is a connection between a grounded circuit conductor and ______, at a separately derived system. - CORRECT ANSWER-a supply-side bonding jumper and an equipment grounding conductor A _____ is the circuit conductors between the final overcurrent device protecting the circuit and the outlets. - CORRECT ANSWER-Branch circuit Finely divided solid material that is a maximum of _______ microns and presents a fire or explosion hazard dispersed and ignited in air is combustible dust. - CORRECT ANSWER-500 A pressure connector is a device that establishes a connection between ________ by means of mechanical pressure and without the use of a solder. - CORRECT ANSWER--two or more conductors -one or more conductors and a terminal A composite optical fiber cable contains - CORRECT ANSWER--optical fibers -current carrying electrical conductors A continuous load is a load where the maximum current is expected to continue for _______ hours or more. - CORRECT ANSWER-3 A ________ is a device by which the conductors of a circuit can be disconnected from their source of supply. - CORRECT ANSWER-Disconnecting means

Content preview

RESIDENTIAL WIREMAN TEST PART
EXAMS AND ANSWERS




The National Electrical Code not intended as ________. -
CORRECT ANSWER-design specification or as an instrucion
manual

The provisions of the national electrical code are considered
necessary for ________. - CORRECT ANSWER-safety

What is not covered within the scope of the national electrical
code? - CORRECT ANSWER-installation in underground
mines

Which chapter of the national electrical code covers
communications systems? - CORRECT ANSWER-chapter 8

The informational annexes of the national electrical code are for
______. - CORRECT ANSWER-informational purposes only

If the current edition of the national electrical code requires the
use of a new product but that product is not yet available then
the _____ may permit the use of a product from the most
recent previous edition. - CORRECT ANSWER-authority
having jurisdiction

A rule that identifies actions that are allowed but not required is
______. - CORRECT ANSWER-Permissive

, It is not necessary to inspect a piece of equipment that has not
been altered or damaged and has been listed by a qualified
electrical testing laboratory is the be installed in a structure -
CORRECT ANSWER-True

Distribution centers located in readily accessible locations
provide _______. - CORRECT ANSWER-Convenience and
safety of operation

Limits on the number of circuits in a single enclosure minimize
the effects from a _______. - CORRECT ANSWER-Ground
fault or short circuit

Where units of measurement are used in the national electrical
code they are given in _______ units. - CORRECT ANSWER-
Inch-pound and/or SI

When a hard conversion is made the ________ may change. -
CORRECT ANSWER-dimensions

Accessible as applied to equipment means admitting close
approach and not guarded by _____. - CORRECT ANSWER-
elevation, locked doors, or other affective means.

The ampacity is the maximum current, in ampheres, that a
conductor can carry continuously under the conditions of use
without exceeding its ______ rating. - CORRECT ANSWER-
Temperature

An arc-fault circuit interrupter, or AFCI is a device which
provides protection from the effects of arc faults by _______. -
CORRECT ANSWER-recognizing characteristics unique to
arcing and functioning to de-energize the circuit when an arc
fault is detected

Document information

Uploaded on
August 15, 2024
Number of pages
15
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$12.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Sold
12
Followers
8
Items
1377
Last sold
6 months ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions