A panelboard for a mobile home shall be rated not less than which of the following? 1. 30 amperes 2. 40 amperes 3. 50 amperes 4. 60 amperes - ANSWER 550.11 (A) Disconnecting Means. A panelboard shall be rated not less than 50 amperes.... The storage batteries used as a source of power for emergency system shall be of suitable rating and capacity to supply and maintain the total load for a minimum of how long? 1. 45 minutes 2. 60 minutes 3. 75 minutes 4. 90 minutes - ANSWER III 700.12 (A) Storage Battery used as a source of power for emergency systems shall be of suitable rating and capacity to supply and maintain the total load for a minimum

Content preview

PSI Online Practice
Examination Correct
100%

A panelboard for a mobile home shall be rated not less than which of the following?

1. 30 amperes

2. 40 amperes

3. 50 amperes

4. 60 amperes - ANSWER 550.11 (A) Disconnecting Means. A panelboard shall be rated not less than 50
amperes....



The storage batteries used as a source of power for emergency system shall be of suitable rating and
capacity to supply and maintain the total load for a minimum of how long?

1. 45 minutes

2. 60 minutes

3. 75 minutes

4. 90 minutes - ANSWER III 700.12 (A) Storage Battery used as a source of power for emergency systems
shall be of suitable rating and capacity to supply and maintain the total load for a minimum period of 1
1/2 hours. ( 4. 90 minutes)



What is the permissible noise exposure limit for an 8-hour day that, if exceeded, requires hearing
protection to be provide? - ANSWER Cal/OSHA Table 3 Allowable Exposure Levels to Sound (page 103)

90dBA - 8 hours

,For pool equipment, the disconnecting means for all ungrounded conductors shall be readily accessible
and within sight from its equipment and shall be located a minimum of how many feet horizontally from
the inside walls of a pool?

1. 5 feet

2. 6 feet

3. 8 feet

4. 10 feet - ANSWER 680.12 Maintenance Disconnecting Means Each means shall be readily accessible
and within sight from its equipment and shall be located at least 1.5 m (5 ft.) horizontally from the inside
walls of a pool.



Disregarding exceptions, conductors used for direct burial applications shall be shielded if rated above
which of the following?

1. 600 volts

2. 1,000 volts

3. 1,200 volts

4. 2,000 volts - ANSWER 310.10 (F) Direct-Burial Conductors Cables rated above 2000 volts shall be
shielded.



What is the required width of the working space in front of electrical equipment with a 22-inch width?

1. 22 inches

2. 24 inches

3. 30 inches

4. 33 inches - ANSWER 110.26(A)(2) The width of the working space in front of the electrical equipment
shall be the width of the equipment or 30 inches, whichever is greatest.



Receptacles in residential units shall be installed such that no point measured horizontally along the
floor line of any wall space is more than how far from a receptacle outlet?

1. 6 feet

2. 8 feet

3. 10 feet

, 4. 12 feet - ANSWER 210.52(A)(1) Receptacles shall be installed such that no point measured horizontally
along the floor line of any wall space is more than 1.8m (6 ft.) from a receptacle outlet.



What is the minimum permitted branch circuit overcurrent protection for a 240-volt, 5,000-watt, 60-
gallon water heater?



1. 20 amperes

2. 25 amperes

3. 30 amperes

4. 35 amperes - ANSWER 5,000/240= 20.8 x 1.25%=26.04 Therefore: 3. 30 amperes

For other than a totally enclosed switchboard or switchgear, what is the minimum amount of space that
shall be provided between the top of an unshielded switchboard or switchgear and any combustible
ceiling?

1. 18 inches

2. 24 inches

3. 30 inches

4. 36 inches - ANSWER 408.18(A) Clearances

From Ceiling. For other than a totally enclosed switchboard of switchgear, a space not less than 900mm
(3 ft.) shall be provided between the top of the switchboard or switchgear and any combustible ceiling



What is the minimum branch-circuit rating for ranges of 8-3/4 kW or more?

1. 20 amperes

2. 30 amperes

3. 40 amperes

4. 50 amperes - ANSWER 210.19(A)(3) Household Ranges and Cooking Appliances. For ranges of 8-3/4 or
more rating, the minimum branch-circuit rating shall be 40 amperes



Equipment grounding conductors of bare or insulated aluminum or copper-clad aluminum shall not be
terminated within how many inches of the earth?

1. 6 inches

2. 12 inches

Document information

Uploaded on
August 13, 2024
Number of pages
17
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$13.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Lecchris
3.8
(6)
Sold
43
Followers
15
Items
3201
Last sold
1 week ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions