ACI Test All Answers Correct - What is the maximum duration allowed between the first and final portions of a composite sample collection? The maximum allowable time between obtaining the first and last portions of a composite sample is 15 minutes. - Should wet sieving of a concrete sample occur after the individual samples are mixed into a composite? False. Wet sieving should not be conducted after the samples are combined; it has distinct timing requirements. - After obtaining a composite sample, within how many minutes must tests for slump, temperature, and air content commence? These tests are required to start within 5 minutes of acquiring the composite sample. - When must test specimens be molded after the composite sample collection? The molding of test specimens should occur within 15 minutes after the collection of the composite sample. - What precautions should be taken with concrete samples to prevent negative effects? Concrete samples should be safeguarded from sunlight, wind, rapid evaporation, and contamination. - What is the minimum volume of concrete sample needed for molding strength test specimens? A minimum concrete sample size of 28 liters (1 cubic foot) is required for this purpose. - Is obtaining a representative sample the main goal of the sampling process? True. Ensuring that the sample is representative is the key objective of the sampling procedure. - How many portions should be collected from a revolving drum truck mixer during sampling? Concrete should be taken from 2 or more sections of the batch when sampling from a revolving drum truck mixer. - What circumstances call for wet sieving of concrete? Wet sieving is necessary if the concrete includes aggregates larger than what is acceptable for testing. - Is it permissible to use three small containers on the subgrade when sampling from a paving mixer? False. This method is not acceptable for obtaining the required concrete samples. --- TEMPERATURE MEASUREMENTS - How long may it take for temperature stabilization when the nominal maximum size (NMS) of coarse aggregate exceeds a certain dimension? It may take up to 20 minutes for the temperature to stabilize when the NMS of coarse aggregate is greater than 3 inches. - What size container is necessary to ensure proper temperature measurement in concrete? The container must be large enough to allow for at least 3 inches (or 3 times the NMS) of concrete to surround the temperature measuring device on all sides. - What accuracy should the temperature measuring device have, and what range must it encompass? The device should accurately measure temperature within ±1°F and cover a temperature range from 30°F to 120°F. - Is a composite sample required if the only intention is to measure temperature? True. A composite sample is not necessary for determining temperature alone. - How frequently should the temperature measuring device be calibrated? The calibration must be performed annually or whenever there is doubt regarding its accuracy.

Meer zien Lees minder
Instelling
Vak









Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
Studie
Vak

Documentinformatie

Geüpload op
6 augustus 2024
Aantal pagina's
9
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

ACI Test All Answers Correct
- What is the maximum duration allowed between the first and final portions of a composite sample
collection?

The maximum allowable time between obtaining the first and last portions of a composite sample is 15
minutes.



- Should wet sieving of a concrete sample occur after the individual samples are mixed into a
composite?

False. Wet sieving should not be conducted after the samples are combined; it has distinct timing
requirements.



- After obtaining a composite sample, within how many minutes must tests for slump, temperature, and
air content commence?

These tests are required to start within 5 minutes of acquiring the composite sample.



- When must test specimens be molded after the composite sample collection?

The molding of test specimens should occur within 15 minutes after the collection of the composite
sample.



- What precautions should be taken with concrete samples to prevent negative effects?

Concrete samples should be safeguarded from sunlight, wind, rapid evaporation, and contamination.



- What is the minimum volume of concrete sample needed for molding strength test specimens?

A minimum concrete sample size of 28 liters (1 cubic foot) is required for this purpose.



- Is obtaining a representative sample the main goal of the sampling process?

True. Ensuring that the sample is representative is the key objective of the sampling procedure.



- How many portions should be collected from a revolving drum truck mixer during sampling?

Concrete should be taken from 2 or more sections of the batch when sampling from a revolving drum
truck mixer.

, - What circumstances call for wet sieving of concrete?

Wet sieving is necessary if the concrete includes aggregates larger than what is acceptable for testing.



- Is it permissible to use three small containers on the subgrade when sampling from a paving mixer?

False. This method is not acceptable for obtaining the required concrete samples.



---



TEMPERATURE MEASUREMENTS



- How long may it take for temperature stabilization when the nominal maximum size (NMS) of coarse
aggregate exceeds a certain dimension?

It may take up to 20 minutes for the temperature to stabilize when the NMS of coarse aggregate is
greater than 3 inches.



- What size container is necessary to ensure proper temperature measurement in concrete?

The container must be large enough to allow for at least 3 inches (or 3 times the NMS) of concrete to
surround the temperature measuring device on all sides.



- What accuracy should the temperature measuring device have, and what range must it encompass?

The device should accurately measure temperature within ±1°F and cover a temperature range from
30°F to 120°F.



- Is a composite sample required if the only intention is to measure temperature?

True. A composite sample is not necessary for determining temperature alone.



- How frequently should the temperature measuring device be calibrated?

The calibration must be performed annually or whenever there is doubt regarding its accuracy.
$12.35
Krijg toegang tot het volledige document:

100% tevredenheidsgarantie
Direct beschikbaar na je betaling
Lees online óf als PDF
Geen vaste maandelijkse kosten


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
bestscores1 Kent State University
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
12
Lid sinds
1 jaar
Aantal volgers
0
Documenten
1369
Laatst verkocht
1 maand geleden
ReadEase

Welcome to ReadEase, your ultimate resource for exam preparation. At ReadEase, we specialize in providing comprehensive study materials and resources to help you excel in your exams. Whether you're preparing for standardized tests, professional certifications, or academic assessments, our finely curated collection covers a wide range of subjects and levels. From practice tests and study guides to expert tips and strategies, we're here to support your journey to success. ReadEase is committed to availing high-quality educational content, helping you thrive and achieve your academic and professional goals. Have any questions? We're just a message away.

Lees meer Lees minder
4.3

4 beoordelingen

5
2
4
1
3
1
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen