EPA 608 Universal Verified Answers 1. Refrigeration technicians who violate the Clean Air Act can: - Lose their EPA certification, be fined, be required to appear in Federal court. 2. After 1995, any supplies of CFC refrigerants to service existing units in the USA can only come from: - Recovery and recycling. 3. Refrigerant that is recovered can be returned to: - The same system or other systems owned by the same person without restriction. 4. Refrigerant cannot be called "reclaimed" unless it: - Has been chemically analyzed and meets the ARI-700 standard. 5. The EPA can require a technician to demonstrate their ability to perform proper procedures for recovering and/or recycling refrigerant. Failure to demonstrate competency can result in: - Revocation of the technician's certification. 6. What characteristic(s) of CFCs make them more likely to reach the stratosphere than most other compounds containing chlorine? - CFCs that contain chlorine but not hydrogen are stable and do not break down in the lower atmosphere after being released, allowing chlorine or bromine to react with ozone, turning it back to oxygen and thus destroying the ozone layer. 7. A system is considered dehydrated when: - The vacuum indicator shows you have reached and held the required finished vacuum. 8. Disposable refrigerant containers are used for: - Virgin refrigerant. 9. Which refrigerant is an HCFC? - R-123, R-124, R-22. 10. What statement is true about an azeotropic refrigerant mixture? - It is a mixture that acts like a single-component refrigerant over its entire range. 11. Chlorofluorocarbons (CFCs) and hydrochlorofluorocarbons (HCFCs) have which of the following in common? - Both are compounds that can degrade the ozone layer. 12. To scrap a disposable cylinder, the internal cylinder pressure should be reduced to at least: - 0 psig. 13. Manifold gauge sets are often color-coded; when this is done, the high-pressure gauge is color coded: - Red. 14. In general, blended refrigerants should be charged: - As a liquid. 15. Blended refrigerants leak from a system: - In uneven amounts due to different vapor pressures. 16. Which of the following gases help form the earth's protective shield? - Stratospheric ozone. 17. In a refrigerant system, the device that changes a low-pressure vapor to a high-pressure vapor is the: - Compressor. 18. Data shows that chlorine in the stratosphere comes mainly from CFCs rather than from natural sources such as volcanoes because: - The rise in the amount of chlorine in the stratosphere matches the rise in CFC emissions; air samples taken from the stratosphere over erupting volcanoes show that volcanoes contribute a small quantity of chlorine to the stratosphere when compared to CFCs. 19. Which atom of the CFC molecule causes ozone depletion? - Chlorine. 20. The ozone layer protects the earth from: - Ultraviolet radiation from the sun. 21. When using any solvent, cleaner, chemical, or refrigerant, you should review: - Material Safety Data Sheets (MSDS). 22. An award of up to what amount may be paid to a person supplying information that leads to a penalty against a technician who is intentionally venting? - $10,000. 23. The Montreal Protocol is: - A treaty among nations that controls the production of CFCs and HCFCs. 24. What is one of the most serious results of damage to the ozone layer? - Increases in human skin cancer. 25. Of the refrigerants listed below, which has the lowest ozone depletion potential (ODP)? - R-22. 26. To determine the maximum allowable pressure to use when checking a system, check: - The design pressure on the equipment nameplate. 27. Ozone depletion potential, or "ODP," is: - A measure of the ability of CFCs and HCFCs to destroy ozone. 28. An example of an HFC refrigerant is: - R-134a. 29. Whenever dry nitrogen from a portable cylinder is connected to a system, what item

Content preview

EPA 608 Universal Verified Answers
1. Refrigeration technicians who violate the Clean Air Act can:

- Lose their EPA certification, be fined, be required to appear in Federal court.



2. After 1995, any supplies of CFC refrigerants to service existing units in the USA can only come from:

- Recovery and recycling.



3. Refrigerant that is recovered can be returned to:

- The same system or other systems owned by the same person without restriction.



4. Refrigerant cannot be called "reclaimed" unless it:

- Has been chemically analyzed and meets the ARI-700 standard.



5. The EPA can require a technician to demonstrate their ability to perform proper procedures for
recovering and/or recycling refrigerant. Failure to demonstrate competency can result in:

- Revocation of the technician's certification.



6. What characteristic(s) of CFCs make them more likely to reach the stratosphere than most other
compounds containing chlorine?

- CFCs that contain chlorine but not hydrogen are stable and do not break down in the lower
atmosphere after being released, allowing chlorine or bromine to react with ozone, turning it back to
oxygen and thus destroying the ozone layer.



7. A system is considered dehydrated when:

- The vacuum indicator shows you have reached and held the required finished vacuum.



8. Disposable refrigerant containers are used for:

- Virgin refrigerant.



9. Which refrigerant is an HCFC?

, - R-123, R-124, R-22.



10. What statement is true about an azeotropic refrigerant mixture?

- It is a mixture that acts like a single-component refrigerant over its entire range.



11. Chlorofluorocarbons (CFCs) and hydrochlorofluorocarbons (HCFCs) have which of the following in
common?

- Both are compounds that can degrade the ozone layer.



12. To scrap a disposable cylinder, the internal cylinder pressure should be reduced to at least:

- 0 psig.



13. Manifold gauge sets are often color-coded; when this is done, the high-pressure gauge is color-
coded:

- Red.



14. In general, blended refrigerants should be charged:

- As a liquid.



15. Blended refrigerants leak from a system:

- In uneven amounts due to different vapor pressures.



16. Which of the following gases help form the earth's protective shield?

- Stratospheric ozone.



17. In a refrigerant system, the device that changes a low-pressure vapor to a high-pressure vapor is the:

- Compressor.



18. Data shows that chlorine in the stratosphere comes mainly from CFCs rather than from natural
sources such as volcanoes because:

Document information

Study
Uploaded on
August 6, 2024
Number of pages
10
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$11.17

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
bestscores1
4.4
(5)
Sold
18
Followers
0
Items
1369
Last sold
1 month ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions