EPA 608 Type 1 All Answers Correct 1. Recovery equipment used for the service or repair of small appliances must be certified by an EPA approved lab if the recovery equipment was made after: - ️ November 15, 1993 2. Recovery devices made before 11-15-93 and used for recovering refrigerant from small appliances must be capable of: - ️ Recovering 80% of the refrigerant whether or not the compressor is operating or achieving a 4 inch vacuum under conditions of ARI 740-1993. 3. EPA's definition of a small appliance includes: - ️ A device manufactured, charged, and hermetically sealed in the factory with a charge of 5 lbs or less. 4. Technicians with a Type 1 small appliance certification are certified to recover refrigerant during the maintenance or repair of: - ️ PTACs (Packaged Terminal Air Conditioners) with 5 lbs or less of refrigerant. 5. EPA requires that all small appliances be equipped with a service aperture or another device that is used when adding or removing refrigerant from the appliance. For small appliances, this service port typically: - ️ Is a straight piece of tubing, called a process tube, that is entered using a piercing valve. 6. The EPA Section 608 certification must be renewed every: - ️ Never. 7. It is an EPA regulation that any person who opens an appliance for maintenance, service, or repair must have at least one self-contained recovery machine available at their place of business. The only exception to this rule is for persons working on: - ️ Small appliances. 8. The sale of CFC & HCFC refrigerants is: - ️ Restricted to technicians who are EPA certified in refrigerant recovery. 9. Anyone who recovers refrigerant during maintenance, service, or repair of small appliances must be certified as either a universal tech or a: - ️ Type 1 tech. 10. When recovering refrigerant from a household refrigerator whose compressor does not run, it is recommended that low and high side access valves be installed because: - ️ It can help speed up recovery and required recovery efficiency. 11. If you install an access fitting into a sealed system: - ️ The fitting should be leak tested before proceeding with recovery. 12. Before beginning a refrigerant recovery procedure, it is always necessary to: - ️ Determine the type of refrigerant in the system. 13. When recovering refrigerant into a non-pressurized container from a refrigerator with an improper compressor: - ️ It is necessary to heat and strike the compressor with a rubber mallet. 14. When checking for the existence of non-condensable gases inside a recovery cylinder, why is it proper procedure to allow the temperature of the cylinder to stabilize at room temperature before taking a pressure reading? - ️ Any comparisons to a pressure-temperature chart are only valid if both the pressure and temperature of the refrigerant are stable. 15. A recovery cylinder that is 1/2 full of recovered R-410A at 90°F, in the absence of non-condensables, will be pressurized to: - ️ 300 psig. 16. When using ______, it is essential to take extra measures (heating/striking) to help release trapped refrigerant from the compressor oil: - ️ Passive system-dependent recovery devices on a small appliance with a non-operating compressor. 17. According to the EPA, which recovery equipment maintenance practice(s) should be performed on a regular basis? - ️ Check recovery device for refrigerant leaks. 18. On a small appliance with an operating compressor that has a completely plugged capillary tube, what is the minimum number of access valves needed to evacuate the refrigerant? - ️ 1 valve on the high side. 19. Which refrigerant is most commonly used as a replacement for R-12 in new household refrigerators? - ️ R-134a. 20. Small amounts of refrigerant have no odor; therefore, if a pungent odor is detected during a system recovery and/or repair: - ️ A compressor burn-out has likely occurred. If R-22 or R-12are exposed to high temperatures, these refrigerants can decompose to form:

Content preview

EPA 608 Type 1 All Answers Correct


1. Recovery equipment used for the service or repair of small appliances must be certified by an EPA-
approved lab if the recovery equipment was made after:

- ✔️ November 15, 1993



2. Recovery devices made before 11-15-93 and used for recovering refrigerant from small appliances
must be capable of:

- ✔️ Recovering 80% of the refrigerant whether or not the compressor is operating or achieving a 4-
inch vacuum under conditions of ARI 740-1993.



3. EPA's definition of a small appliance includes:

- ✔️ A device manufactured, charged, and hermetically sealed in the factory with a charge of 5 lbs or
less.



4. Technicians with a Type 1 small appliance certification are certified to recover refrigerant during the
maintenance or repair of:

- ✔️ PTACs (Packaged Terminal Air Conditioners) with 5 lbs or less of refrigerant.



5. EPA requires that all small appliances be equipped with a service aperture or another device that is
used when adding or removing refrigerant from the appliance. For small appliances, this service port
typically:

- ✔️ Is a straight piece of tubing, called a process tube, that is entered using a piercing valve.



6. The EPA Section 608 certification must be renewed every:

- ✔️ Never.



7. It is an EPA regulation that any person who opens an appliance for maintenance, service, or repair
must have at least one self-contained recovery machine available at their place of business. The only
exception to this rule is for persons working on:

- ✔️ Small appliances.

, 8. The sale of CFC & HCFC refrigerants is:

- ✔️ Restricted to technicians who are EPA certified in refrigerant recovery.



9. Anyone who recovers refrigerant during maintenance, service, or repair of small appliances must be
certified as either a universal tech or a:

- ✔️ Type 1 tech.



10. When recovering refrigerant from a household refrigerator whose compressor does not run, it is
recommended that low and high side access valves be installed because:

- ✔️ It can help speed up recovery and required recovery efficiency.



11. If you install an access fitting into a sealed system:

- ✔️ The fitting should be leak tested before proceeding with recovery.



12. Before beginning a refrigerant recovery procedure, it is always necessary to:

- ✔️ Determine the type of refrigerant in the system.



13. When recovering refrigerant into a non-pressurized container from a refrigerator with an improper
compressor:

- ✔️ It is necessary to heat and strike the compressor with a rubber mallet.



14. When checking for the existence of non-condensable gases inside a recovery cylinder, why is it
proper procedure to allow the temperature of the cylinder to stabilize at room temperature before
taking a pressure reading?

- ✔️ Any comparisons to a pressure-temperature chart are only valid if both the pressure and
temperature of the refrigerant are stable.



15. A recovery cylinder that is 1/2 full of recovered R-410A at 90°F, in the absence of non-condensables,
will be pressurized to:

- ✔️ 300 psig.

Document information

Study
Uploaded on
August 6, 2024
Number of pages
5
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$12.00

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
bestscores1
4.4
(5)
Sold
18
Followers
0
Items
1369
Last sold
1 month ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions