100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4.2 TrustPilot
logo-home
Tentamen (uitwerkingen)

NCLE TEST QUESTIONS AND VERIFIED SOLUTIONS BY EXPERTS 2024/2025 GRADED A+.

Beoordeling
-
Verkocht
-
Pagina's
32
Cijfer
A+
Geüpload op
04-08-2024
Geschreven in
2024/2025

1. Assessment of the quality ofthe peripheral curves(blends of a rigid contact lens) is achieved by the use of thea. profile analyzer b. shadow graph c. keratometer d. burton light: a. profile analyzer 2. Contact lens power should be specified ina. back vertex power b. sphero-cylinder power c. power in situ d. posterier apical radius: a. back vertex power 3. The slit-lamp illumination that gives an overall view of the cornea but limits detail isa. sclerotic scatter b. diffuse c. specular reflection d. oscilatory: b. diffuse 4. When a keratometric miers reflected off a soft contact lens are only clear when the wearer blinks, the lens fit is tooa. small b. large c. steep d. flat: 5. Transient keratometric mier distortion is usually due toa. pre-ocular tear film abnormalities b. prolonged rigid lens wear c. prolonged soft lens wear d. irregular corneal astigmatism: a. pre-ocular tear film abnormalities 6. Epithelial edema which manifests itself clinically as central corneal haze, is verified by the slit lamp using sclerotic scatter illumination.What specific technique does the examiner use to see this condition? a. the naked eye and an angle between the slit lamp beam and the eye of 90Ú b. the blue cobalt filter of the slit lamp and an angle of about 45Ú c. the green filter of the slit lamp with high magnification d. high magnification and an angle between the beam and scope of 180:Úa. the naked eye and an angle between the slit lamp beam and the eye of 90Ú 7. With a rigid contact lens in place a flourescein pattern shows a narrow bend horizontally wih a concentration of 3 / 32 flourescein inferiorly and superiorly under the lens.Which one of the following type of astigmatism is represented by this pattern? a. lenticular astigmatism b. residual astigmatism c. against the rule astigmatism d. with the rule astigmatism: d. with the rule astigmatism 8. Refractive Rx -3.00 -1.00 x 170 K's 42.00 @ 170/43.00 @ 80 Given the above Rx and K's he following diagnostic toric soft lens was used: B.C. 8.8 Power -3.00 -1.00 x 180 During dianostic evalutation, the above lens rotated 10 clockwise.The lens ordered should have an axis of: a. 10 b. 180 c. 170 d. 160: b. 180 9. Given the same circumstances from the above question, once the correct- ly ordered lens has been dispensed, the rotational marks should settle at . a. 6 o clock b. 10 clockwise rotation c. 10 counter clockwise rotation d. none of the above: b. 10 clockwise rotation 10. An instrumentthat allowssimultaneous verification oflens diameter, optic zone width, and peripheral curve width is: a. measuring magnifier b. ophthalmometer c. profile analyzer d. radiuscope: a. measuring magnifier (the book says d. radiuscope) 11. The instrument used for magnification of the edge of a rigid CL is a

Meer zien Lees minder











Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Documentinformatie

Geüpload op
4 augustus 2024
Aantal pagina's
32
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

NCLE TEST QUESTIONS
AND VERIFIED
SOLUTIONS BY EXPERTS
2024/2025 GRADED A+.






,1. Assessment of the quality of the peripheral curves (blends of a rigid contact lens) is achieved by the use of the-
a. profile analyzer
b. shadow graph
c. keratometer
d. burton light: a. profile analyzer
2. Contact lens power should be specified in-
a. back vertex power
b. sphero-cylinder power
c. power in situ
d. posterier apical radius: a. back vertex power
3. The slit-lamp illumination that gives an overall view of the cornea but limits detail is-
a. sclerotic scatter
b. diffuse
c. specular reflection
d. oscilatory: b. diffuse
4. When a keratometric miers reflected off a soft contact lens are only clear when the wearer blinks, the lens fit
is too-
a. small
b. large
c. steep
d. flat: c. steep
5. Transient keratometric mier distortion is usually due to-
a. pre-ocular tear film abnormalities
b. prolonged rigid lens wear
c. prolonged soft lens wear
d. irregular corneal astigmatism: a. pre-ocular tear film abnormalities
6. Epithelial edema which manifests itself clinically as central corneal haze, is verified by the slit lamp using
sclerotic scatter illumination. What specific technique does the examiner use to see this condition?
a. the naked eye and an angle between the slit lamp beam and the eye of 90Ú
b. the blue cobalt filter of the slit lamp and an angle of about 45Ú
c. the green filter of the slit lamp with high magnification
d. high magnification and an angle between the beam and scope of 180:Úa. the naked eye and an angle between the slit
lamp beam and the eye of 90Ú
7. With a rigid contact lens in place a flourescein pattern shows a narrow bend horizontally wih a concentration of


,flourescein inferiorly and superiorly under the lens. Which one of the following type of astigmatism is represented by
this
pattern?
a. lenticular astigmatism
b. residual astigmatism
c. against the rule astigmatism
d. with the rule astigmatism: d. with the rule astigmatism
8. Refractive Rx -3.00 -1.00 x 170
K's 42.00 @ 170/43.00 @ 80
Given the above Rx and K's he following diagnostic toric soft lens was used:
B.C. 8.8
Power -3.00 -1.00 x 180
During dianostic evalutation, the above lens rotated 10 clockwise. The lens ordered should have an axis of:

a. 10
b. 180
c. 170
d. 160: b. 180
9. Given the same circumstances from the above question, once the correct- ly ordered lens has been dispensed,
the rotational marks should settle at
.
a. 6 o clock
b. 10 clockwise rotation
c. 10 counter clockwise rotation
d. none of the above: b. 10 clockwise rotation
10. An instrument that allows simultaneous verification of lens diameter, optic zone width, and peripheral curve
width is:
a. measuring magnifier
b. ophthalmometer
c. profile analyzer
d. radiuscope: a. measuring magnifier (the book says d.
radiuscope)
11. The instrument used for magnification of the edge of a rigid CL is a
.



, a. radiuscope
b. shadowgraph
c. profile analysis
d. keratometer: b. shadowgraph
12. Mary is wearing in her right eye RGP lens with a base curve of 43.50 and a power of +2.75. The doctor refracts
-0.75 sphere over this lens. If you wish to order her a new lens with a curve of 43.00, what will the new power be?

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
tutor23 Chamberlain College Of Nursing
Bekijk profiel
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
14
Lid sinds
1 jaar
Aantal volgers
4
Documenten
71
Laatst verkocht
7 maanden geleden
online top tutor 2024

all updated documents

1.3

3 beoordelingen

5
0
4
0
3
0
2
1
1
2

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen