EPA Lead Exam Already Graded A 1. How many parts per million (ppm) are in 1%? - Answer: 1% equals 10,000 ppm. 2. What is the allowable limit of lead in dry surface paint as measured by XRF? - Answer: The limit for lead in dry surface paint is 1.0 mg/cm². 3. What is the allowed quantity of lead in dry surface paint when tested through paint chip analysis? - Answer: The permissible lead content in dry paint found via chip testing is 5,000 ppm, which equates to 5% by weight. 4. What are the dust clearance levels for various surfaces? - Answer: - Floors: 40 µg/ft² - Window sills: 250 µg/ft² - Wells: 400 µg/ft² - Outside concrete: 800 µg/ft² - Soil in high-contact areas: 400 ppm - Soil in low-contact areas: 1,200 ppm 5. What is the maximum allowable lead concentration in drinking water? - Answer: The allowable lead level in drinking water is 15 parts per billion (ppb) or 15 mg/L. 6. At what blood lead level (BLL) is a child considered to be at risk? - Answer: A child is considered at risk with a blood lead level of 5 µg/dL. 7. What is the NIOSH threshold for blood lead levels of concern? - Answer: NIOSH considers a blood lead level of 25 µg/dL a cause for concern. 8. What is the permissible OSHA blood lead level? - Answer: The permissible level set by OSHA is 40 µg/dL. 9. What is the blood lead level at which OSHA requires medical removal? - Answer: OSHA mandates medical removal at a blood lead level of 50 µg/dL. 10. What was the allowed lead content in paint before 1978? - Answer: Before 1978, paint was allowed to contain up to 0.06% lead, or 600 ppm. 11. As of 2009, what is the maximum lead percentage permitted in paint? - Answer: The permitted lead concentration in paint is now reduced to 0.009%, or 90 ppm. 12. What does the TCLP determine regarding hazardous waste? - Answer: The Toxicity Characteristic Leaching Procedure (TCLP) standard for hazardous waste is set at 5 ppm. 13. What does TSCA Title IV, Section 402/404 require from the EPA? - Answer: This section directs the EPA to develop training and certification requirements for individuals performing risk assessments and for lead professionals. 14. True or False: The EPA's debris rule allows lead waste from renovation of residential housing to be disposed of as municipal waste. - Answer: True. 15. True or False: Sections 1012 and 1013 of Title X refer specifically to HUD regulations. - Answer: True. 16. Are lead inspections required for homes built before 1978? - Answer: No, lead inspections are not mandatory for pre-1978 housing. 17. True or False: There is no set time frame for lead abatement in housing, but all hazards must be addressed in houses funded with $25,000 or more from HUD. - Answer: True. 18. True or False: The CDC's latest ruling states children face health risks with blood lead levels of just 5 µg/dL, with significant health risks emerging at 80 µg/dL or higher. - Answer: True. 19. True or False: XRF readings for clearance tests must be taken in any four rooms where abatement or renovation occurred. - Answer: False. 20. True or False: While it’s beneficial for inspectors to understand respiratory protection standards, it is not a requirement for EPA lead inspectors. - Answer: True. 21. What minimum protective gear should an assessor wear when performing inspections or risk assessments in homes built before 1978? - Answer: Assessors should wear booties and rubber gloves. 22. If an abatement project is scheduled in a house from the 1950s, is a risk assessment required by Title X law beforehand? - Answer: No, a risk assessment is not required prior to work beginning.

Content preview

EPA Lead Exam Already Graded A


1. How many parts per million (ppm) are in 1%?

- Answer: 1% equals 10,000 ppm.



2. What is the allowable limit of lead in dry surface paint as measured by XRF?

- Answer: The limit for lead in dry surface paint is 1.0 mg/cm².



3. What is the allowed quantity of lead in dry surface paint when tested through paint chip analysis?

- Answer: The permissible lead content in dry paint found via chip testing is 5,000 ppm, which equates
to 5% by weight.



4. What are the dust clearance levels for various surfaces?

- Answer:

- Floors: 40 µg/ft²

- Window sills: 250 µg/ft²

- Wells: 400 µg/ft²

- Outside concrete: 800 µg/ft²

- Soil in high-contact areas: 400 ppm

- Soil in low-contact areas: 1,200 ppm



5. What is the maximum allowable lead concentration in drinking water?

- Answer: The allowable lead level in drinking water is 15 parts per billion (ppb) or 15 mg/L.



6. At what blood lead level (BLL) is a child considered to be at risk?

- Answer: A child is considered at risk with a blood lead level of 5 µg/dL.



7. What is the NIOSH threshold for blood lead levels of concern?

- Answer: NIOSH considers a blood lead level of 25 µg/dL a cause for concern.

,8. What is the permissible OSHA blood lead level?

- Answer: The permissible level set by OSHA is 40 µg/dL.



9. What is the blood lead level at which OSHA requires medical removal?

- Answer: OSHA mandates medical removal at a blood lead level of 50 µg/dL.



10. What was the allowed lead content in paint before 1978?

- Answer: Before 1978, paint was allowed to contain up to 0.06% lead, or 600 ppm.



11. As of 2009, what is the maximum lead percentage permitted in paint?

- Answer: The permitted lead concentration in paint is now reduced to 0.009%, or 90 ppm.



12. What does the TCLP determine regarding hazardous waste?

- Answer: The Toxicity Characteristic Leaching Procedure (TCLP) standard for hazardous waste is set at
5 ppm.



13. What does TSCA Title IV, Section 402/404 require from the EPA?

- Answer: This section directs the EPA to develop training and certification requirements for
individuals performing risk assessments and for lead professionals.



14. True or False: The EPA's debris rule allows lead waste from renovation of residential housing to be
disposed of as municipal waste.

- Answer: True.



15. True or False: Sections 1012 and 1013 of Title X refer specifically to HUD regulations.

- Answer: True.



16. Are lead inspections required for homes built before 1978?

- Answer: No, lead inspections are not mandatory for pre-1978 housing.

, 17. True or False: There is no set time frame for lead abatement in housing, but all hazards must be
addressed in houses funded with $25,000 or more from HUD.

- Answer: True.



18. True or False: The CDC's latest ruling states children face health risks with blood lead levels of just 5
µg/dL, with significant health risks emerging at 80 µg/dL or higher.

- Answer: True.



19. True or False: XRF readings for clearance tests must be taken in any four rooms where abatement or
renovation occurred.

- Answer: False.



20. True or False: While it’s beneficial for inspectors to understand respiratory protection standards, it is
not a requirement for EPA lead inspectors.

- Answer: True.



21. What minimum protective gear should an assessor wear when performing inspections or risk
assessments in homes built before 1978?

- Answer: Assessors should wear booties and rubber gloves.



22. If an abatement project is scheduled in a house from the 1950s, is a risk assessment required by Title
X law beforehand?

- Answer: No, a risk assessment is not required prior to work beginning.



23. What are the standard procedures for collecting a dust sample?

- Answer: The process includes:

1. Outlining the sampling area

2. Measuring 1/10 to 1 square foot

3. Preparing the sampling tube

4. Wearing gloves

Document information

Study
Uploaded on
August 2, 2024
Number of pages
17
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$11.03

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
bestscores1
4.4
(5)
Sold
18
Followers
0
Items
1369
Last sold
1 month ago


Reviews from verified buyers



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions