IBC Fireproofing Exam Review Questions Fully Solved.
Special inspections - Answer _____ for sprayed fire resistant materials applied to floor, roof and wall assemblies and structural members shall be in accordance with Sections 1705.13.1 to 1705.13.6. Approved construction documents - Answer Special inspections shall be based on the fire resistance design as designated in the _____. After - Answer Special inspections shall be performed _____ the rough installation of electrical, automatic sprinkler, mechanical and plumbing systems and suspension systems for ceilings, where applicable. P.388 IBC 1705.13.1 Physical and visual tests - Answer 1. Condition of substrates 2. thickness of application; 3. density in pounds per cubic foot; 4.Bond strength adhesion/cohesion; 5. Condition of finished application. 1705.13.2 Structural member surface conditions - Answer The surfaces shall be prepared in accordance with the approved fire-resistance design and the written instructions of APPROVED manufacturers. The prepared surface of structural members to be sprayed shall be inspected ______ the application of the sprayed fire-resistant material. - Answer BEFORE (1705.13.2 IBC pg. 388) 1705.13.3 Application; BEFORE and AFTER - Answer The substrate shall have a minimum ambient temperature_____ and _____ application as specified in the written instructions of APPROVED manufacturers. The area for application shall be _____ during and after _____ as required by the written instructions of approved manufacturers. (1705.13.3) - Answer Ventilated; application