Low Pressure Boiler COF NY Exam Questions With Verified Answers A fill line in an oil burner system is a line used to: - answerFill the storage tank with oil. The aquastat is located - answerBelow the water line. All heating, combustion, and cooking equipment shall be installed with adequate clearances from _______ construction. - answerCombustible The equipment must be provided with ______ or the building construction shall be _____ _____. - answerInsulation. Fire Protected During operation the surface of combustible construction materials will not be raised to a temp higher than _____ degrees F. - answer170 degrees Equipment shall be so that the means of access for ordinary operation and maintenance will not be _______. - answerHazardous Acceptance Tests: Boilers shall not be placed in operation until they have been _____ and ____ and an equipment ____ _____ has been issued by the ______. - answerInspected and tested. Use permit, commissioner Periodic Inspections: All boilers must be inspected at least _____ a _____ including chimney connections. - answerOnce a year Owners Annual Statement: The owner of each boiler shall file an _____ written statement with the ________, specifying the _____of each boiler and ______ for inspection. - answerAnnual, commissioner, location, arrangement. Field Tests: all piping and oil storage tanks shall be _______ tested for tightness by the ______ before the system is operated. - answerHydrostatically, contractor The piping shall be tested at _____ times the max working pressure applicable to that part of the piping system but at a pressure ____ than the test pressure required for the storage tank. - answer1/2, less The min pressure for testing tanks shall be ____ times the max working pressure but in no case less than ____ psi. - answer1 1/2, 25 psi The hydrostatic pressure must be maintained until all ____ and _____ have been visually inspected for ___, but in no case less than _____ hour. - answerJoints, connections, leaks, 1/2 hour. A record must be kept of the pressure test showing the name of the _____ and the _____ at which the piping and tank were tested. - answerContractor, pressure Gas piping must be tested by the _____ before operation. - answerContractor For oil burning systems, ____ ____ giving instructions for the care and operation of the system shall be permanently located in an easily _____ and _____ location near the equipment. - answerInstruction Cards, visible, accessible No oil burning equipment shall be operated until an equipment ____ _____ has been issued by the commissioner, the requirements of the ____ ____ control code have been met and until the approval for the storage of ____ ____ has been given by the fire commissioner. - answerUse permit, air pollution, fuel oil Every oil burning installation that is not fully automatic or requires preheating shall be operated under the direct supervision of a person holding a ____ ___ ______ issued by the FD. - answerCOF Such person must be in the building at ____ ____ while in operation and present in the _____ _____ during startup. - answerAll times, boiler room After any repairs to the boiler are made, ______ shall check the repairs and the functioning of all ____ _____ and the positioning of the ______. - answerOperators, control devices, valves All heating and combustion equipment that is fired with solid, liquid, or gas fuels, must comply with the requirements of the ____ _____ _____ code. - answerAir pollution control Low Temp Equipment have a temp of ____ degrees at the point of leaving the equipment. - answer600 or less Median Temp Equipment have a temp of between ___ and ___ degrees F at the point of leaving the equipment under normal conditions. - answer600 and 1000 High Temp Equipment have a temp of ____ or ____ degrees F leaving the equipment. - answer1000 or greater Ventilation shall be capable of providing at least ____ cfm of air for each gallon of oil per ____. - answer36, hour


Document information

Uploaded on
July 20, 2024
Number of pages
7
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers
$11.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
sirjoel
3.6
(18)
Sold
133
Followers
13
Items
12782
Last sold
1 month ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions

Whoops! We can’t load your doc right now. Try again or contact support.