S-95 FDNY TEST STUDY GUIDE Latest Update 2024 -2025 Actual Exam Questions and 100% Verified Correct Answers Guaranteed A+ Activated alarm entries - CORRECT ANSWER: (1) date and time activated (2) location and detector type (3) probable cause (4) Department unit and officer (5) name and C of F number of the C of F holder who made the entry Alarm log book entries - CORRECT ANSWER: The alarm log book shall be divided into 4 separate sections as set forthbelow. Each section shall have a sufficient number of pages to allow for entries for at least one year Alarm Silence Switch or Button - CORRECT ANSWER: Is used to silence the building audible and visual devices after evacuation is complete while the source of alarm is being investigated. Never reset the fire alarm system until the condition is verified by the FDNY personnel. all Portable Fire Extinguishers must be checked by a W -96 Certificate of Fitness holder from FDNY approved company - CORRECT ANSWER: annually AUDIO AND VISUAL NOTIFICATION DEVICES - CORRECT ANSWER: The appliances include bells, horns, speakers, strobes, text displays or a combination of these devices. The audible and/or visual notification alert the occupants of a fire or other emergency condition requiring action. Beam detectors - CORRECT ANSWER: Used to protect large areas. This detector consists of a light beam that when broken by anyt combustible particle will trigger the detector bound book - CORRECT ANSWER: Log books shall be retained for a period of three (3) years from the date of the last entry. CARBON MONOXIDE DETECTOR - CORRECT ANSWER: is in alarm condition and cannot be reset, this could indicate that carbon monoxide is still in the premises. Central Station Transmitter - CORRECT ANSWER: A device that receives alarm signals from protected premises and retransmits those signals to the Fire Department's Bureau of Fire Communication Class A fires - CORRECT ANSWER: Usually involve wood, paper, cloth, or cardboard and typically happen in dry -storage areas, dining areas, garbage areas, and restrooms. Class B fires - CORRECT ANSWER: Usually involve flammable liquids and grease and typically start in kitchens and maintenance areas. Class C - CORRECT ANSWER: electrical fires Class D - CORRECT ANSWER: metals, such as magnesium, titanium, zirconium, sodium, liquid, and potassium Class K fires - CORRECT ANSWER: Fires in cooking appliances that involve combustible cooking media (vegetable or animal oils and fats). Combination detector - CORRECT ANSWER: Alarm -initiating device capable of detecting an abnormal condition by more than one means. The most common combination detector is the fixed -temperature/rate -of-rise heat detector. Daily entry for the log book four sections - CORRECT ANSWER: 1) Certificate Fitness holder's name (2) Certificate of Fitness number( 3) time started( 4) time relieved Duct smoke detectors - CORRECT ANSWER: Smoke detectors that sample the air moving through the air distribution system ductwork or plenum; upon detecting smoke, the detector sends a signal to shut down the air distribution unit, close any associated smoke dampers, or initiate smoke control syste m operations. Elevator lobby smoke detectors - CORRECT ANSWER: are smoke detectors that when activated will recall elevators automatically to the designated landing. Fire Alarm Control Panel (FACP) - CORRECT ANSWER: Monitors inputs and controls output through various types of circuits.The Panel activates the building audible and visual device connected to the fire alarm (horn/strobes) Fire Alarm Signal - CORRECT ANSWER: Manual fire alarm pull station, smoke detector, water flow switch in the presence of a fire or fire signature. FIRE ALARM SYSTEM OFF -LINE - CORRECT ANSWER: It is mandatory to take the system "off -line" by notifying the FDNY approved central station company monitoring the fire alarm beforehand to prevent the unnecessary dispatching of the Fire Department fire extinguisher - CORRECT ANSWER: (1) the fire extinguisher is fully charged; (2) it is in its designated place;
Preview 2 out of 6 pages
Exam (elaborations)
S-95 FDNY TEST STUDY GUIDE Latest Update Actual Exam Questions and 100% Verified Correct Answers Guaranteed A+
Preview 2 out of 6 pages
S-95 FDNY TEST STUDY GUIDE Latest Update Actual Exam Questions and 100% Verified Correct Answers Guaranteed A+
Content preview
Document information
- Uploaded on
- July 19, 2024
- Number of pages
- 6
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers
$21.49
Wrong document? Swap it for free
Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF
Available in package deal
Package deal
CERTIFICATE OF FITNESS FOR SUPERVISION OF FIRE ALARM SYSTEMS S-95 LATEST EXAMS