Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Exam (elaborations)

JOURNEYMAN OIL BURNER QUESTIONS AND ANSWERS 2024 #14

Rating
-
Sold
-
Pages
19
Grade
A+
Uploaded on
09-07-2024
Written in
2023/2024

JOURNEYMAN OIL BURNER QUESTIONS AND ANSWERS 2024 #14

Institution
Course

Content preview

JOURNEYMAN OIL BURNER QUESTIONS AND ANSWERS 2024 #14

1/4" - correct answer Threads of drainage fittings shall be tapped as to allow _____
pitch per foot

4 lbs - correct answer Lead used for safe pans shall not be less than ________ per
square foot

Copper Tube, Cast Iron, Stainless steel, ABS, PVC DWV - correct answer Name 3
allowable materials for the DWV system "underground"

1-1/4" - 1 dfu's
1-1/2" - 3 dfu's
2" - 4 dfu's
3" 6 dfu's
4" - dfu's - correct answer What are the fixture unit values for the following traps

Double fixture fitting - correct answer What type of fitting is used for continuous waste
and venting of lavatories back to back?

1" - correct answer Caulk joints for cast iron bell and spigot shall be filled with molten
lead to a depth of not less than ________?

Wye, Combination Wye w/ 1/8 bend, Long sweep - correct answer What type of fitting
or fittings can be used to connect horizontal drainage to another horizontal drainage
line?

- Each horizontal drainage pipe shall be provided with a cleat at its upper terminal
- Horizontal run more than 100'
- Each horizontal change of direction exceeding 135°
- Front Main Cleanout - correct answer Cleanout locations required by code

100' - correct answer Maximum distance a cleanup can be spaced apart

12"
18" - correct answer Minimum clearance in front of a cleanup for 2" or less
Minimum clearance in front of a cleanup for 2" or more

20' - correct answer Underfloor cleanup shall not be located more than _____ from an
access door, trap door, or crawl hole

Back Water Valve - correct answer When plumbing fixtures are installed on a floor level
lower than the next upstream manhole cover of the sewer, such drainage piping shall be
protected from backflow of sewage by a ____________

,20 - correct answer Sewage ejectors receiving the discharge of water closets or ruinals
shall have a discharge capacity not less than ___ gallons per minute

2" - correct answer What is the minimum size discharge pipe for an ejector installed in a
single dwelling?

2" - correct answer The lowest inlet connected to the ejector pump shall have a
clearance of not less than ____ from the high water or starting level of the sump.

Yes, with prior approval of the AHJ - correct answer Can macerating toilet systems be
installed instead of a sewage pump system

3/4" - correct answer What is the minimum size discharge pipe for a macerating toilet
system

1/4" per foot - correct answer What is the minimum pitch required fora 2" horizontal
drain?

Swing check valve - correct answer The discharge line from an ejector pump shall be
provided with an accessible ___________ and gate or ball valve.

Downstream of the backwater valve - correct answer Where shall the gate valve be
located on the discharge line on an ejector pump

8' - correct answer Drainage connections shall not be made into a drainage piping
system within ________ of an vertical or horizontal change in direction of a stack
containing suds producing fixtures.

10' Head of water for 15 minutes
5 psi for and air test - correct answer What are the requirements when testing the DWV
system Water and Air?

When the dwelling is more than 200' away from the sewer. - correct answer When is the
public sewer considered not being available?

2' away from the building - correct answer At what point does the building sewer begin?

DFU's - correct answer How is the size of the building sewer determined?

300' - correct answer What is the maximum distance allowed between approved
manholes?

12" - correct answer When a water pipe and sewer pipe are placed in a common trench
what is the minimum distance above the top of the sewer line to the bottom of the water
pipe?

, 12" - correct answer When a water pipe and sewer pipe are placed in a common trench
what is the minimum clear horizontal distance the water pipe shall be from the sewer
pipe?

By taking 80% of the total DFU's = 173 DFU's - correct answer A 4' drainage line has to
be run at a pitch of 1/8" per foot. How is the maximum fixture unit low now determined?

Provide minimum requirements and standards for the protection of the public health,
safety, and welfare. - correct answer Purpose of plumbing code.

Capped - correct answer Openings into drainage or vent system excepting those
opening to which plumbing fixtures are properly connected or which constitute vent
terminals shall be permanently plugged or _________ in an approved manner.

Owner or owners agent - correct answer Who is responsible for maintaining the
plumbing and drainage system in a building?

Work or systems that have already been installed prior to the effective date of the
existing code. - correct answer What is meant by the term "existing work"?

Blockages or leaks - correct answer What type of work is exempt from a plumbing
permit?

180 Days - correct answer If work is not started, how many days is a permit valid?

After it has been tested, inspected, and approved - correct answer When can plumbing
work be covered and concealed?

Person with the permit, doing the work - correct answer Who notifies the authority have
jurisdiction when plumbing work is ready for inspections?

Prevent siphonage - correct answer What is the purpose of a vacuum relief valve

To slow corrosion of the inside of the tank - correct answer What is the purpose of the
anode rod?

To send cold water to the bottom of the tank - correct answer What is the purpose of the
dip tube?

To prevent siphonage and back pressure on the dip tube. - correct answer What is the
purpose of the anti-siphon hole?

When the water temperature drops below a set temperature the immersion element
turns on to reheat the water. - correct answer Explain how the electric immersion
elements work on an electric water heater.

Written for

Course

Document information

Uploaded on
July 9, 2024
Number of pages
19
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$14.49
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller
Seller avatar
puritywanjihia
5.0
(2)

Also available in package deal

Get to know the seller

Seller avatar
puritywanjihia havard
Follow You need to be logged in order to follow users or courses
Sold
4
Member since
3 year
Number of followers
1
Documents
484
Last sold
1 month ago
THE BOOK STORE LIMITED CORPORATION

A+ DOCUMENTS i.e, Test Banks ,Revision Guide etc Visit my site to get lecture notes summaries and practice questions to acquire higher grades in your exams. Let us excel together!!!!!. I know how frustrating it can get with all the assignments mate. I have taken my quality time to review and gather as many documents from different courses .Thanks.

5.0

2 reviews

5
2
4
0
3
0
2
0
1
0

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions