During electrocautery you should... - ANSWER: ✔✔Pause Recording



SSEPs are less reliable in patients with... - ANSWER: ✔✔Neuromuscular disease



After-discharges occur after what? - ANSWER: ✔✔Direct cortical stimulation



In order to reduce stimulus artifact, the ground electrode shoudl be placed... - ANSWER: ✔✔On the
limb between the stimulating and recording electrodes



Which of the following is the most effected by halogenated agents? - ANSWER: ✔✔Posterior Tibial
cortical potential



The nerve roott entry levels for the ulnar nerve are.. - ANSWER: ✔✔C8-T1



When doing a C5 decompression involving the axillary nerve which muscle should you record from? -
ANSWER: ✔✔Deltoid



Train stimuli are used for TcMEP's in order to... - ANSWER: ✔✔Overcome anesthetic suppression of
synaptic transmissions in the motor pathway



What is the preferred alternate when the PTN is unavailable? - ANSWER: ✔✔Peroneal



Nyquist Frequency - ANSWER: ✔✔One half the frequency of the recorded signal



A decrease in the power spectral edge indicates.. - ANSWER: ✔✔a greater proportion of EEG power at
the lower frequencies

,Why do we use electrodes with the same metals? - ANSWER: ✔✔To prevent electrode polarization



Which of the following drugs has an appreciable effect on peripheral nerve APs - ANSWER: ✔✔none



Which one of the following is an inhibitory neurotransmitter - ANSWER: ✔✔GABA



Stimulating the median nerve at the wrist yields an Erbs point response at 10ms and an CV of 60m/s.
What is the distance between the cathode and the Erb's point recording electrode - ANSWER: ✔✔60cm



What are SSEP and MEP used simultaneously? - ANSWER: ✔✔Spinal cord damage can occur in only one
tract causing loss of MEp but not SSEP



Common Mode Rejection - ANSWER: ✔✔Is the cancellation of signals that are common to both inputs
of the ampifier



Ankylosis - ANSWER: ✔✔Fused Joint



Where is the ABR wave V generated? - ANSWER: ✔✔Mdbrain



If you cannot replace an electrode that has come out during surgery you? - ANSWER: ✔✔use a
duplicate



A patient with the temperature of 30 debrees C will have - ANSWER: ✔✔increased latencies



Which would not be considered contamination of the sterile field - ANSWER: ✔✔reaching underneath
the surgeon's gown to grab his pager



Personal Protection Devices (PPDs) consist of - ANSWER: ✔✔gloves, masks, gowns



When an electrode fall on the floor you - ANSWER: ✔✔you immediately pick it up to dispose of it in a
sharps container

, when testing BAEP's you get a wave I on your contralateral ear montage. What do you do? - ANSWER:
✔✔Check ear phones for porper side stimulation



When no phase reversal is present in an anterior-posterior cortical grid recording - ANSWER: ✔✔The
maximum amplitude response is closest to the central sulcus



The Artery of Admkiewicz is - ANSWER: ✔✔a major feeder vessel to the spinal cord



Which of the following is a barbiturate? - ANSWER: ✔✔Methohexital



Which electrode is regarded as an effective stimulator during facial nerve recordings? - ANSWER:
✔✔Bipolar concentric EMG needle



The primary risk associated with sublaminar wire placement is - ANSWER: ✔✔Dorsal column injury



One of the risks of a wake up test is? - ANSWER: ✔✔Accidental extubation



A 60Hz artifact would most likely be caused by: - ANSWER: ✔✔Infusion Pump



Your initial signal is 0.5microV inside a background noise of 2microV. What will the signal to noise ratio
be after 400 averages? - ANSWER: ✔✔5



What is not an advantage of epidural recording? - ANSWER: ✔✔absence of significant artifact



When securing PTN stimulators you want to make sure - ANSWER: ✔✔the anode is distal to the cathode



which of thefolowing is most consistent with a discrete lesion of the medial geniculate body? - ANSWER:
✔✔No changes in waves I-V

Document information

Study
Uploaded on
June 23, 2024
Number of pages
21
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers
$14.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
EXAMSTUDYPLUG
4.5
(242)
Sold
385
Followers
107
Items
20953
Last sold
2 weeks ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions