• Verkeerd document? Gratis ruilen
  • Geschreven door studenten die geslaagd zijn
  • Direct beschikbaar na je betaling
  • Online lezen of als PDF
Verkopen
Kies je studieland
Kies je taal
Document preview thumbnail
Voorbeeld 3 van de 22 pagina's
Tentamen (uitwerkingen)

NCLE Practice Test Questions and Answers All Correct

Document preview thumbnail
Voorbeeld 3 van de 22 pagina's

NCLE Practice Test Questions and Answers All Correct A Correct Statement regarding epithelial cells is that they: a)Comprise the posterior layer of the cornea b)Are unable to regenerate c)Comprise the thickest layer of the cornea d) Have the ability to reproduce - Answer-d) have the ability to reproduce Which of the following prescriptions indicates against-the-rule astigmatism? a)-4.50 +1.00 x75 b)-4.50 +1.00 x 180 c)-4.50 -1.00 x 165 d)4.50 -1.00 x 180 - Answer-a)-4.50 +1.00 x75 When a keratometer is being calibrated, which of the following targets will provide the most reliable result? a)the single-cut anterior surface of a high-plus lens b)a perfectly flat highly polished mirror c) a set of steell balls of known radii d)the unfinished posterior surface of a low-minus lens - Answer-c) a set of steel balls of known radii Inadequate movement of a soft lens can be corrected by using a lens that a) has a steeper base curve b) has a smaller diameter c) has a larger diameter d) has a higher water content - Answer-b)has a smaller diameter A long-term, successful, hydrogel contact lens wearer suddenly develops dry eyes. Which of the following is most likely to cause this problem? a) Use of oxidative solution b) use of rewetting drops c) use of anti-histamines d) Wearing of lenses in the wrong eyes - Answer-c) use of anti-histamines During slit-lamp evaluation, on upward gaze, a patient's soft contact lenses move 0.5 to 1mm when the patient blinks. These lenses are: a) a good fit b) too loose c) too tight d) too large - Answer-a) a good fit A new daily wearer of soft lenses returns for the first follow up visit with itching, burning, injected eyes. The most likely cause of these problems is: a) solution reaction b) giant-cell papillary conjunctivitis c) a lens fit that is too loose d) inability to wear soft lenses - Answer-a) solution reaction Which of the following is the mode of slit-lamp illumination used to view the early stages of microcystic edema? a) Retroillumination b) Direct illumination c) Parrallelpiped d) Oscillation - Answer-a) Retroillumination Which of the following changes is best able to improve oxygen transmissibility to a patient's cornea? a) Increasing tear exchange b) Increasing Dk c) Increasing optical zone diameter d) Increasing CN bevel - Answer-b) Increasing Dk


Documentinformatie

Geüpload op
12 juni 2024
Aantal pagina's
22
Geschreven in
2023/2024
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden
$11.19

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kan je een ander document kiezen. Je kan het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Verkocht
4
Volgers
3
Items
668
Laatst verkocht
1 jaar geleden




Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via Bancontact, iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo eenvoudig kan het zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen

Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.