Geschrieben von Student*innen, die bestanden haben Sofort verfügbar nach Zahlung Online lesen oder als PDF Falsches Dokument? Kostenlos tauschen 4,6 TrustPilot
logo-home
Document preview thumbnail
Vorschau 2 aus 14 Seiten
Prüfung

API 653 SECTION 6 EXAM 100% QUESTIONS WITH CORRECT ANSWERS 2024

Document preview thumbnail
Vorschau 2 aus 14 Seiten

API 653 SECTION 6 EXAM 100% QUESTIONS WITH CORRECT ANSWERS 2024 The purpose of in-service inspections of AST's is to assure : - ANSWERS continued tank integrity. What type of inspection may be done by owner/ operator personnel and/or authorized inspectors? - ANSWERS Routine in-service inspection The external condition of storage tanks shall be monitored by close visual inspection from the ground on a routine basis.This inspection can be done by owner/operator personnel,and can be done by the other than Authorized Inspector. The interval of such inspections shall not exceed: - ANSWERS 1 month All tanks shall be given a visual external inspection by an Authorized Inspector, at least every: - ANSWERS 5years or at RCA/4N years,whichever is less External ultrasonic thickness measurements of the shell, when used and when the corrosion rate is not known, are taken at intervals not to exceed: - ANSWERS 5 years Who assures the competency of the personnel performing cathodic protection surveys ? - ANSWERS Owner/ operator A candidate tank is: - ANSWERS A tank for which corrosion rates are not known Two reasons for an internal inspection of an aboveground storage tank are to ensure that the : - ANSWERS bottom is not severely corroded and to gather data on the minimum bottom & shell thickness Who assures the quality and completeness of NDE results obtained during a formal internal inspection? - ANSWERS The API authorized inspector & competent NDE person If an internal inspection is required solely for the purpose of determining the condition and integrity of the tank bottom, the internal inspection: - ANSWERS must be made only after the tank is removed from service and readied for entry The initial inspection interval for an aboveground storage tank shell not exceed _____ years (excluding leak protection, corrosion mitigation or containment safeguards ). - ANSWERS 10 A tank's bottom is inspected. What thickness must the bottom plate be at the next inspection ? The tank bottom/foundation design has no means for detection and containment of a bottom leak. - ANSWERS 0.10 inches What is the maximum subsequent internal inspection interval for an AST where the Corro Procedure is used & there is no release prevention barrier (RPB)? - ANSWERS 20 What is the maximum subsequent inspection interval for an AST using corrosion rate procedure where tank has proper Release Prevention Barrier(RPB)? - ANSWERS 30 years Which of the following is a "likelihood" factor when doing RBI on an AST? - ANSWERS operating temperature Which of the following is a "consequence" factor when doing RBI on an AST? - ANSWERS dike containment capabilities As an alternate to the set maximum intervals of internal inspection given in paragraph 6.4.2 of API 653, an owner- operator may establish the subsequent internal inspection interval using: - ANSWERS risk-based inspection (RBI) procedures Name the three types of records the owner/ operator is required to keep for AST's . - ANSWERS construction records, inspection history,and repair/alteration history Which of the following items would NOT be included in an inspector's report following an external or internal inspection of an Atmospheric Storage Tank ? - ANSWERS Corrosion rate of the tank' s roof. Some repairs to a tank may be made after it has returned to service. Which of the items listed below is considered critical and must be made prior to returning the tank to service ? - ANSWERS Bottom or shell repairs A 30 feet diameter Atmospheric Storage Tank with single lap welded seams has a lower shell course shell plate replaced.What joint factor would you use for the evaluation of the tank shell vertical seams. - ANSWERS 0.35" Personnel performing ______shall meet the qualifications identified in paragraph 12.1.1.2 of API 653 , but need not be certified in accordance with appendix D of API 653 - ANSWERS Nondestructive examinations. The exterior surface of the tank bottom is known as the ________ - ANSWERS Bottom side (3.6) What is a device that protects atmospheric storage tanks by maintaning the pressure difference between the tank vapor space and the outside atmosphere to just a few ounces per in^2? - ANSWERS Pressure-vacuum vent (4.2.2) What is the most common type of atmospheric storage tank? - ANSWERS Fixed cone roof tank (4.2.3) What is the purpose of a geodesic dome on a tank? - ANSWERS Strenght (4.2.3) Why are atmospheric storage tanks generally inspected? - ANSWERS To protect the environment as well as the health and safety of employees and public (5.1) What is the primary cause of deterioration of steel storage tanks? - ANSWERS Corrosion


Dokument Information

Hochgeladen auf
7. juni 2024
Anzahl der Seiten
14
geschrieben in
2023/2024
Typ
Prüfung
Enthält
Fragen & antworten
$14.99

Falsches Dokument? Kostenlos tauschen Innerhalb von 14 Tagen nach dem Kauf und vor dem Herunterladen kannst du ein anderes Dokument wählen. Du kannst den Betrag einfach neu ausgeben.
Geschrieben von Student*innen, die bestanden haben
Sofort verfügbar nach Zahlung
Online lesen oder als PDF

Seller avatar
Bewertungen des Ansehens basieren auf der Anzahl der Dokumente, die ein Verkäufer gegen eine Gebühr verkauft hat, und den Bewertungen, die er für diese Dokumente erhalten hat. Es gibt drei Stufen: Bronze, Silber und Gold. Je besser das Ansehen eines Verkäufers ist, desto mehr kannst du dich auf die Qualität der Arbeiten verlassen.
STUDENTSCORE
4.3
(3)
Verkauft
13
Anhänger
6
Sachen
1368
Zuletzt verkauft
3 Jahren vor



Warum sich Studierende für Stuvia entscheiden

on Mitstudent*innen erstellt, durch Bewertungen verifiziert

Geschrieben von Student*innen, die bestanden haben und bewertet von anderen, die diese Studiendokumente verwendet haben.

Nicht zufrieden? Wähle ein anderes Dokument

Kein Problem! Du kannst direkt ein anderes Dokument wählen, das besser zu dem passt, was du suchst.

Bezahle wie du möchtest, fange sofort an zu lernen

Kein Abonnement, keine Verpflichtungen. Bezahle wie gewohnt per Kreditkarte oder Sofort und lade dein PDF-Dokument sofort herunter.

Student with book image

“Gekauft, heruntergeladen und bestanden. So einfach kann es sein.”

Alisha Student

Arbeitest du an deiner Quellenangabe?

Erstelle korrekte Quellenangaben in APA, MLA und Harvard mit unserem kostenlosen Zitiergenerator.

Arbeitest du an deiner Quellenangabe?

Häufig gestellte Fragen

Ups! Dein Dokument kann gerade nicht geladen werden. Versuch es erneut oder kontaktiere den Support.