Oil Burners License Exam Questions and Answers Updated|2024

Document preview thumbnail
Preview 1 out of 3 pages

Oil Burners License Exam Questions and Answers Updated|2024 The main function of the primary control is: Locking out on safety in the event of flame failure Power must be provided to an electric blower control board on terminals: L1 and L2 Once a PSC motor starts The centrifugal switch turns off the electricity to the capacitor and the start windings Materials who's electrons are so loosely bound that they can be persuaded to move with very little pressure allowing electricity to flow are called Conductors Oil burners can make CO even when no smoke is present True Corrosion in the flu pipe may occur if Flue gas temperature is below the dewpoint and sulfur oxide's combine with water To avoid condensing and the flu pipe and oil fired appliance should have a minimum growth stock temperature of 350°F All persons assisting and working under the supervision of a person holding a certificate as an oil burner technician must hold current apprentice certificates issued by Department of fire services True What size pipe is used to cross connect tank outlets piping 1/2 inch Fuel return piping from an appliance shall Enter the top of the tank Delayed ignition may be caused by Unvented pressure regulator Installation of oil safety valves and oil pressure reducing valve Reduces the chance of a return line leak What is an installation Complete and ready for operation of any oil burning appliance Energizing the ignition circuit during the entire burn cycle reduces Ignition component life Fuel can be transferred from a tank to an appliance by pressurizing the tank False What device must be equipped with an air proving switch Both, draft inducers and power-venters What is a safety control Any control used to prevent unsafe operation of the controlled equipment A non-resident steam or hot water boiler having a minimum safety relief valve capacity over 200,000 BTU/hr requires certificate of inspection from the department of fire services Prior to the initial firing, every 3 years after What is the closest distance a supply tank can be to the burner 5 feet Doing a combustion pretest on and oil burning appliance will not tell you anything this is why they generally are performed False What is the minimum oil supply line size for a residential system 3/8 inch A cad cell primary control can lock out safety because All of the above- dirty, faulty, not sensing flame As heating oil gets colder it's viscosity thickens: Increase The purpose of the oil burner nozzle is to: Atomize, pattern and meter the oil The primary control must be capable of All of the above A decrease in CO2 with an increase in excess air will give a drop in stack temperature True Minimum net stack temperature of above 350°F must be maintained To avoid condensation and maintain draft The primary control must be capable of reacting to The presence or absence of flame The two principal combustible elements in number two fuel oil are nitrogen and carbon False If a stack type controller fails you must Replace it with an approved type controller When wiring multiple circulators they should be wired in Parallel Oil viscosity problems can be solved by installing a ———— nozzle and increasing oil pressure Smaller Residential burner ignition systems normally operate at what primary voltage 120 A Call for too much heat on a hot water heating job may be caused by Thermostat wire is shorted out High viscosity problems brought on by cold oil may be minimized by All of the above From whom must you obtain a permit for removal of a fuel oil storage tank The head of the local fire department

Content preview

Oil Burners License Exam >> Questions and Answers Updated|2024
The main function of the primary control is: Locking out on safety in the event of flame failure
Power must be provided to an electric blower control board on terminals: L1 and L2
Once a PSC motor starts The centrifugal switch turns off the electricity to the capacitor and the start windings
Materials who's electrons are so loosely bound that they can be persuaded to move with very little pressure allowing electricity to flow are called Conductors
Oil burners can make CO even when no smoke is present True
Corrosion in the flu pipe may occur if Flue gas temperature is below the dewpoint and sulfur oxide's combine with water
To avoid condensing and the flu pipe and oil fired appliance should have a minimum growth stock temperature of 350°F
All persons assisting and working under the supervision of a person holding a certificate as an oil
burner technician must hold current apprentice certificates issued by Department of fire services
True
What size pipe is used to cross connect tank outlets piping 1/2 inch
Fuel return piping from an appliance shall Enter the top of the tank
Delayed ignition may be caused by Unvented pressure regulator
Installation of oil safety valves and oil pressure reducing valve Reduces the chance of a return line leak
What is an installation Complete and ready for operation of any oil burning appliance
Energizing the ignition circuit during the entire burn cycle reduces Ignition component life
Fuel can be transferred from a tank to an appliance by pressurizing the tank False
What device must be equipped with an air proving switch Both, draft inducers and power-
venters
What is a safety control Any control used to prevent unsafe operation of the controlled equipment
A non-resident steam or hot water boiler having a minimum safety relief valve capacity over 200,000 BTU/hr requires certificate of inspection from the department of fire services Prior to the initial firing, every 3 years after
What is the closest distance a supply tank can be to the burner 5 feet

Document information

Uploaded on
June 6, 2024
Number of pages
3
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers
$11.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
MBOFFIN
3.7
(133)
Sold
775
Followers
218
Items
5633
Last sold
21 hours ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions