he MPFL is the main passive stabilizer against lateral patella displacement and is at its tightest in what degree of flexion? A. 0-30 degrees B. 0-180 degrees C. 60-90 degrees - ANSWER-A. 0-30 degrees What landmark does Schottles Point refer to when discussing MPFL? A. distal patella attachment B. superior patella attachment C. femoral attachment D. tibial attachment - ANSWER-C. femoral attachment Which statement regarding MPFL is TRUE: A. it inserts on the upper 1/2 (superior) of the patella B. it inserts on the lateral femur C. it inserts on the lower 1/2 (inferior) of the patella D. it prevents medial subluxation of the patella E. all of the above - ANSWER-A. it inserts on the upper 1/2 (superior) of the patella True or False: the use of the MPFL template included in the 3.9 mm BioComposite SwiveLock implant MPFL kit is advantageous in establishing the proper position of the femoral insertion of the MPFL, which is critical for maintaining proper joint biomechanics of the patellofemoral joint throughout range of motion. - ANSWER-True When using the MPFL template included in the 3.9 mm BioComposite SwiveLock implant MPFL kit the insertion point of the guide pin is approximately: A. 1 mm anterior to the posterior cortex extension line; 2.5 mm distal to the posterior articular border of the medial femoral condyle; proximal to the level of the posterior point of Blumensaat's line B. 2.5 mm anterior to the posterior cortex extension line; 1 mm distal to the posterior articular border of the medial femoral condyle; proximal to the level of the posterior point of Blumensaat's line C. 1 mm anterior to the posterior cortex extension line; 2.5 mm distal to the posterior articular border of the medial femoral condyle; distal to the level of the posterior point of Blumensaat's line - ANSWER-A. 1 mm anterior to the posterior cortex extension line; 2.5 mm distal to the posterior articular border of the medial femoral condyle; proximal to the level of the posterior point of Blumensaat's line The 3.9 BioComposite SwiveLock MPFL kits come in which of the two options: A. MPFL Implant System with BioComposite FastThread Interference Screw for femoral fixation and MPFL Implant System with TightRope implant for femoral fixation B. MPFL Implant System with InternalBrace implant for femoral fixation and MPFL Implant System with BioComposite FastThread Interference Screw for femoral fixation C. MPFL Implant System with PEEK Interference Screw for femoral fixation and MPFL Implant System with TightRope Implant for femoral fixation

Show more Read less
Institution
Arthrex ACE Trainings- Sports
Course
Arthrex ACE Trainings- Sports









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Arthrex ACE Trainings- Sports
Course
Arthrex ACE Trainings- Sports

Document information

Uploaded on
May 23, 2024
Number of pages
13
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

Arthrex ACE Trainings- Sports Exam Questions and Answers 100% Verified
The MPFL is the main passive stabilizer against lateral patella displacement and is at its
tightest in what degree of flexion?
A. 0-30 degrees
B. 0-180 degrees
C. 60-90 degrees - ANSWER-A. 0-30 degrees
What landmark does Schottles Point refer to when discussing MPFL?
A. distal patella attachment
B. superior patella attachment
C. femoral attachment
D. tibial attachment - ANSWER-C. femoral attachment
Which statement regarding MPFL is TRUE:
A. it inserts on the upper 1/2 (superior) of the patella
B. it inserts on the lateral femur
C. it inserts on the lower 1/2 (inferior) of the patella
D. it prevents medial subluxation of the patella
E. all of the above - ANSWER-A. it inserts on the upper 1/2 (superior) of the patella
True or False: the use of the MPFL template included in the 3.9 mm BioComposite SwiveLock implant MPFL kit is advantageous in establishing the proper position of the femoral insertion of the MPFL, which is critical for maintaining proper joint biomechanics
of the patellofemoral joint throughout range of motion. - ANSWER-True
When using the MPFL template included in the 3.9 mm BioComposite SwiveLock implant MPFL kit the insertion point of the guide pin is approximately: A. 1 mm anterior to the posterior cortex extension line; 2.5 mm distal to the posterior articular border of the medial femoral condyle; proximal to the level of the posterior point
of Blumensaat's line
B. 2.5 mm anterior to the posterior cortex extension line; 1 mm distal to the posterior articular border of the medial femoral condyle; proximal to the level of the posterior point
of Blumensaat's line
C. 1 mm anterior to the posterior cortex extension line; 2.5 mm distal to the posterior articular border of the medial femoral condyle; distal to the level of the posterior point of Blumensaat's line - ANSWER-A. 1 mm anterior to the posterior cortex extension line; 2.5 mm distal to the posterior articular border of the medial femoral condyle; proximal to the level of the posterior point of Blumensaat's line
The 3.9 BioComposite SwiveLock MPFL kits come in which of the two options:
A. MPFL Implant System with BioComposite FastThread Interference Screw for femoral
fixation and MPFL Implant System with TightRope implant for femoral fixation
B. MPFL Implant System with InternalBrace implant for femoral fixation and MPFL Implant System with BioComposite FastThread Interference Screw for femoral fixation
C. MPFL Implant System with PEEK Interference Screw for femoral fixation and MPFL Implant System with TightRope Implant for femoral fixation
D. MPFL Implant System with InternalBrace implant for femoral fixation and MPFL Implant System with PEEK Interference Screw for femoral fixation - ANSWER-A. MPFL Implant System with BioComposite FastThread Interference Screw for femoral fixation and MPFL Implant System with TightRope implant for femoral fixation
What is the appropriate diameter and length of the gracilis autograft tendon needed for MPFL reconstruction when using the 3.9mm BioComposite SwiveLock Implant MPFL Kit?
A. Approximately 2 mm in diameter and minimum 18 cm in length
B. Approximately 12 mm in diameter and minimum 25 cm in length
C. Approximately 8 mm in diameter and minimum 16 cm in length
D. Approximately 4 mm in diameter and minimum 18 cm in length
E. All of the above are acceptable - ANSWER-D. Approximately 4 mm in diameter and minimum 18 cm in length

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Topgrades20 West Virginia University
View profile
Follow You need to be logged in order to follow users or courses
Sold
12
Member since
2 year
Number of followers
10
Documents
812
Last sold
10 months ago

3.5

2 reviews

5
0
4
1
3
1
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions