Backflow Prevention Questions With 100% Correct Answers.

Document preview thumbnail
Preview 1 out of 2 pages

Air gap separation - ANSI A112.1, Severe High, High or Low Hazard, Backsiphonage/Backpressure. Only absolute means of preventing backflow. Pipe applied Atmospheric Type Vacuum Breaker - ASSE 1001, High or Low Hazard, Backsiphonage only, NO continuous pressure, No downstream valve Anti-siphon Fill Valve, W.C. - ASSE 1002, High or Low Hazard, Backsiphonage only Hose Connection Vacuum Breaker - ASSE 1011, High or Low Hazard, Backsiphonage, Low Head Backpressure, No continuous pressure Backflow preventer with Intermediate Atmospheric Vent - ASSE 1012, Low Hazard, Low Pressure, Backsiphonage/Backpressure, Low pressure Boilers or cooling towers, No Additives. Reduced Pressure Principle Backflow Preventer - ASSE 1013, High or Low Hazard, Backsiphonage/Backpressure, Main Supply lines, commercial or chemically treated boilers or chillers, Main Hospital lines and equipment, tanks with submerged inlets. Reduced Pressure Principle Detector Check Assembly - ASSE 1047, High or Low Hazard Fire sprinkler systems, Installed on a fire protection system Containing Any Additive or anti-freeze. Double Check Backflow Prevention Assembly - ASSE 1015, Low Hazard Only, would not present a hazard to health, Main Supply lines, cookers, tanks or vats containing non-toxic substances. Double Check Detector Check Assembly - ASSE 1048, Low Hazard Only Fire sprinkler systems, fire protection system that contains only public water, no booster pump, storage, or auxiliary water, No Chemical and/or non-toxic fire protection systemVacuum Breaker Wall Hydrant, Freeze-resistant, Automatic Draining Type - ASSE 1019, High or Low Hazard, Backsiphonage Low Head Backpressure, No continuous pressure, negligible backpressure in the 1.0 psi to 2.0 psi range, no continuous pressure over 12 hrs. Wall Hydrant Hose Bib. Pressure Vacuum Breaker Assembly - ASSE 1020, High or Low Hazard, Backsiphonage Only, continuous pressure is OK because the air inlet and check valve are spring-loaded, Irrigation systems, plating tanks, livestock watering systems, supply to submerged inlets.


Document information

Uploaded on
May 21, 2024
Number of pages
2
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers
$10.19

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Brainarium
3.8
(339)
Sold
2052
Followers
1048
Items
24335
Last sold
2 hours ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions

Whoops! We can’t load your doc right now. Try again or contact support.