API 653 Data Sheets Questions and Answers 100% Correct
API 653 Data Sheets Questions and Answers 100% Correct Fitness For Service - Answer- API 579 Low Pressure Storage Tanks - Answer- API 620 Risked Based Inspection - Answer- API 580 Cathodic Protection - Answer- API 651 Tank Bottom Linings - Answer- API 652 Welding on in service equipment containing flammables - Answer- API 2201 NDE Procedure Guidlines - Answer- ASME Section V Acceptance Standards for RT of welds - Answer- ASME Section 8, Div. 1 Alternative evaluation for pits and LTA's - Answer- ASME Section 8, Div. 2 Welder Qualification - Answer- ASME Section IX Weld Procedure Qualification - Answer- ASME Section IX Impact testing method and equipment requirements - Answer- ASTM A370 Requirement for new welding electrodes - Answer- AWS NDE personnel qualification (RT and UT flaw detection) - Answer- ASNT SNT-TC-1A API 650 Appendix for frangible roofs - Answer- Appendix F API 650 Appendix for hot tanks - Answer- Appendix M Maximum allowed vertical length of pits on a tank shell - Answer- 2" in 8" Line Max allowed length of pits in the critical zone that can be repaired by weld build up - Answer- 2" in 8" arc Radial length of critical zone measured from shell - Answer- 3" Bottoms- suggested pad thickness - Answer- 3-4" Minimum distance between clusters of surface porosity - Answer- 4" Minimum dimension of shell lap-patch - Answer- 4" Minimum radius of shell flush-patch - Answer- 6" When calculating tmin for shell LTA, minimum distance away from a rivet where "E" is always 1.0 - Answer- 6" Minimum size of a bottom lap-patch that does NOT cross a bottom seam - Answer- 6" Minimum distance between a bottom lap patch and the shell for patches that do NOT extend to the shell - Answer- 6" If reusing shell plates, minimum distance to cut from existing shell welds (if plates are not deseamed) - Answer- 6" Minimum diagnostic length of RT for vertical or horizontal welds - Answer- 6" Minimum length of RT when qualifying a welder with RT using a coupon or 1st production weld - Answer- 6" Minimum length of RT when qualifying a weld operator with a test coupon - Answer- 6" Minimum distance to overlap a shell weld when using a lap patch - Answer- 6" Area to dig when checking for soil-to-air corrosion - Answer- 6-12" Typical size of a vacuum box - Answer- 6"X30" Minimum dimension of a shell flush patch - Answer- 12" or 12 times thickness of replacement plate, whichever is greater Bottoms-minimum distance a 3 lap joint can be from: other 3 lap joints, the shell or annular plate joints - Answer- 12" Minimum dimension of bottom lap patch that crosses a bottom seam - Answer- 12" Foundations- suggested height above grade for new tank bottoms - Answer- 12" When adding a shell flush patch that extends to a horizontal shell weld, minimum distance to cut the horizontal weld past the new vertical welds - Answer- 12" Length of shell to bottom weld that if repaired is considered either a major repair or alteration - Answer- 0" Typical anchor profile of steel surface required for installation of a tank bottom lining - Answer- 1.5-4.0 mils Maximum undercut of a vertical weld and nozzle weld - Answer- 1/64" Maximum undercut of a horizontal weld - Answer- 1/32" Maximum diameter of surface porosity cluster - Answer- 3/32" Maximum allowed discontinuity in a bend test - Answer- 1/8" Minimum size of nameplate letters - Answer- 5/32" Minimum external projection of bottom plate on an existing tank (from toe of shell to btm FW) - Answer- 3/8" Maximum amount of peaking allowed in vertical welds - Answer- 1/2" When calculating tmin for shell LTA, minimum distance away from a weld where "E" is always 1.0 - Answer- 1" or 2t Minimum overlap of a shell lap patch used to cover a hole ( edge of hole to edge of patch) - Answer- 1" When performing PT, minimum distance to clean beyond area to be examined - Answer- 1" When performing MT, minimum distance to clean beyond area to be examined - Answer- 1" Maximum amount of banding allowed in horizontal welds - Answer- 1" Minimum overlap required for single welded lap joints - Answer- 1" Minimum external projection of bottom plate on a new tank - Answer- 2" Minimum overlap of previously test surfaces when using a vacuum box - Answer- 2" Minimum overlap of a bottom lap patch used to cover corroded area (edge of corrosion to edge of patch) - Answer- 2" Minimum distance of bottom lap patch fillet weld to nearest existing bottom weld - Answer- 2" Minimum radius of a shell lap patch - Answer- 2" If reusing bottom plates, minimum distance to cut from existing bottom welds (if plates are not deseamed) - Answer- 2" If reusing roof plates, minimum distance to cut from existing roof welds (if plates are not deseamed) - Answer- 2" Dimension of shell flush patch that is considered either a major repair or alteration - Answer- 12" Dimension of shell vertical weld if repaired or replaced is considered a major repair or alteration - Answer- 12" Maximum width of bottom patch in the critical zone - Answer- 24" Minimum radial width of annular plate (distance between shell and nearest bottom fillet weld) - Answer- 24" Maximum distance of eye to part to count as a visual exam - Answer- 24" Minimum height of liquid above new nozzle during the hot tap operation - Answer- 36" Minimum length of RT when qualifying a welding operator with RT of first production weld - Answer- 36" Length of sweep board used when checking for banding or peaking - Answer- 36" Maximum distance between welder ID stamps on a tank weld - Answer- 36" Maximum size of a shell lap patch (vertical and horizontal dimension) - Answer- 48" X 72" Maximum distance between tank settlement survey points across the inside of the tank - Answer- 10' Maximum shunt spacing on a floating roof - Answer- 10' Maximum distance between tank settlement survey points around the outside diameter of the tank - Answer- 32' Maximum distance between RT's in horizontal welds when welding to existing shell plates - Answer- 50' Tank size for galvanic CP systems - Answer- 60' Tank diameter when variable point design method should always be used to calculate shell tmin - Answer- 200' Minimum offset between vertical welds in adjacent courses - Answer- 5t Minimum size of bottom welds - Answer- Full Fillet Nozzle size that never requires a repad - Answer- Less than or equal to 2nps On existing tank, new nozzle must have insert plate if shell is over 1/2" thick and shell material does not meet current MDMT requirements - Answer- 4NPS Maximum pipe size when using RT elliptical shot (double wall technique, double wall view) - Answer- 3NPS (3 1/2" OD) Maximum nozzle size that can be hot tapped when course thickness is 1/2" and shell has unknown toughness - Answer- 4NPS
Document information
- Uploaded on
- May 8, 2024
- Number of pages
- 13
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers