Gas Fitter 2 Practice Test Questions And Answers 100% Verified
Gas Fitter 2 Practice Test Questions And Answers 100% Verified A room heater installed in either a sleeping area or public area shall be: A. direct vent only B. equipped with a regulator C. equipped with a fan D. equipped with an on / off switch on the wall - answerB What type of vent must be used when the vent of a wall furnace will be concealed in a partition wall? A. B vent B. L vent C. BH vent D. BW vent - answerD Single wall vent connectors: A. may pass through floors, ceilings or roofs provided a metal thimble is used B. may pass through floors, ceilings or roofs provided the required minimum distance from combustible material is maintained C. may pass through floors, ceilings or roofs provided they are insulated D. shall not pass through floors, ceilings or roofs - answerD BW vent shall be used only with an approved: A. decorative appliance B. down flow furnace C. revertible flue boiler D. recessed wall furnace - answerD What must be done during the installation of a gas log fireplace? A. Make sure there is a metal mesh screen in front of the fireplace B. Secure the chimney damper in the open position C. Install a pressure regulator D. Install a metal chimney liner - answerB When can a certified hose be used to connect a construction heater to temporary piping? A. Only if a lever handle shut off valve is installed upstream of the hose B. Only if the hose is 15 feet long C. Never - answerA Which of the following is acceptable when a fireplace insert is installed? A. A metal chimney linear B. The existing fireplace flue C. BW vent D. A tile lined fireplace flue? - answerA An unvented infra-red heater can be installed in ________ application A. A warehouse B. A commercial building C. An industrial building D. All of the above - answerD Dirt pockets are required on: A. Decorative appliances B. Gas logs C. Room heaters D. None of the available choices - answerD What diameter and length of a dirt pocket is required when a drop line is 3-inch diameter? A. 3 inch diameter by 3 inches long B. 1 inch diameter by 3 inches long C. 3/4 inch diameter by 3 inches long D. 2 inch diameter by 3 inches long - answerD What type of room heater maybe installed in a bathroom? A. Natural draft B. Direct fired C. Forced draft D. Direct vent - answerD What safety control protects a steam boiler if the condensate pump fails to return water to the boiler? A. High pressure limit control B. Low pressure limit control C. Flame safeguard control D. Low water cut off - answerD The relief valve for a residential low-pressure hot water boiler system should be? A. 14.7 psia B. 15 psia C. 30 psig D. 30 psia - answerC A backflow prevent used in a boiler system should be located in the: A. Over flow line connected to the drain B. Return line close to the boiler C. 1/4
Document information
- Uploaded on
- April 30, 2024
- Number of pages
- 157
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers