• Wrong document? Swap it for free
  • Written by students who passed
  • Immediately available after payment
  • Read online or as PDF
Sell
Where do you study
Your language
Document preview thumbnail
Preview 2 out of 8 pages
Exam (elaborations)

Arthrex Sports IOT (Day 5/test) Exam Questions With Correct Answers

Document preview thumbnail
Preview 2 out of 8 pages

Family of burrs provides maximum visibility due to the following - Answer clearshroud/hood The power pick instrument was initially designed to do - Answer micro fracture procedures The torpedoes shaver had which of the following features - Answer A tapered cottical tip T/F the power rasp attachment is a motion device that creates a smooth flat surface - Answer False Which shaver oscialtes by its most agressive tissue resection and control - Answer Agg (agressive) How many hand pieces can be connected and controlled simultaneously by the synergy resection console? - Answer 2 What is the largest arthroscopic section for the bipolar RF Products? - Answer Shoulder The bipolar ablation breaks down tissue by the following process? - Answer Chemical reaction The metal detection feature on the synergy fr bipolar ablation system performs what function? - Answer Suspends power to the probe when the tip is in close proximity of the scope or metal instruments When using bipolar RF technology, the clinical guidelines include? - Answer All of the above The default ablation setting levels for the mp90 probe is? - Answer 7 Ablation The 3 biproducts of ablation are? - Answer Bubbles, Frictional Heat, Light emission What are some techniques surgeons use the rf bipolar wands for? - Answer All of the above T/F when removing the orange cap and plugging in the pressure sensor is the first step into your set up procedure for the dual wave arthroscopy? - Answer T The purpose of the shaver boost mode on the dual wave arthroscopy pump is? - Answer Increase the pressure when shaver is activated T/F The dual wave arthroscopy pump is designed to opperate as either inflow-outflow or an inflow only pump? - Answer T If the dual wave arthroscopy pump height is 1ft above the operative site what is the differential btw the displayed pressure and actual pressure? - Answer 22mmhg The main talking points in introducing the synergy Uhd imaging platform? - Answer All of the above What type of light engine is in the synergy uhd4 all in 1 camera system? - Answer LED What are the fluid management options the nanoscope operative arthroscopy system? - Answer Syringe, gravity, and pump systems The target used space for the nanoscope operative arthroscopy system include? - Answer Clinic, Procedure Rooms, ORs The nanoscope operative arthroscopy system differs from its competitors all of the following ways except? - Answer Offering the camera with the smallest diameter Surgical repair of the lateral ankle ligament of the Atfl is most often accomplished with what procedure? - Answer The modified brostrum gold procedure When someone suffers an ankle sprain what ligament is involved most commonly? - Answer ATFL (Anterior Talo-Fibula Ligament) T/F Arthrex recommends using the IB implant for later ankle instability with or without a repair of the Atfl? - Answer F T/F the 4.75mm Swivelock anchor for lateral ankle instability is recommended to be placed in the Talus however the surgeon can place it in ? As they wish? - Answer T T/F the internal brace implants allows for earlier weight bearing while protecting the ligament repair? - Answer T What is the Arthrex suggested technique on fibertape suture positioning for IB augmentation? - Answer Talus to fibula over the top of the ATFL repair Which of the following plates contains features to accommodate the syndesmosis tightrope implant? - Answer All of the above

Content preview

Arthrex Sports IOT (Day 5/test) Exam Questions With Correct Answers Family of burrs provides maximum visibility due to the following - Answer clearshroud/hood
The power pick instrument was initially designed to do - Answer micro fracture procedures
The torpedoes shaver had which of the following features - Answer A tapered cottical tip
T/F the power rasp attachment is a motion device that creates a smooth flat surface - Answer False
Which shaver oscialtes by its most agressive tissue resection and control - Answer Agg (agressive)
How many hand pieces can be connected and controlled simultaneously by the synergy resection console? - Answer 2
What is the largest arthroscopic section for the bipolar RF Products? - Answer Shoulder
The bipolar ablation breaks down tissue by the following process? - Answer Chemical reaction
The metal detection feature on the synergy fr bipolar ablation system performs what function? - Answer Suspends power to the probe when the tip is in close proximity of the scope or metal instruments
When using bipolar RF technology, the clinical guidelines include? - Answer All of the above
The default ablation setting levels for the mp90 probe is? - Answer 7 Ablation
The 3 biproducts of ablation are? - Answer Bubbles, Frictional Heat, Light emission What are some techniques surgeons use the rf bipolar wands for? - Answer All of the above
T/F when removing the orange cap and plugging in the pressure sensor is the first step into your set up procedure for the dual wave arthroscopy? - Answer T
The purpose of the shaver boost mode on the dual wave arthroscopy pump is? - Answer Increase the pressure when shaver is activated
T/F The dual wave arthroscopy pump is designed to opperate as either inflow-outflow or an inflow only pump? - Answer T
If the dual wave arthroscopy pump height is 1ft above the operative site what is the differential btw the displayed pressure and actual pressure? - Answer 22mmhg
The main talking points in introducing the synergy Uhd imaging platform? - Answer All of the above
What type of light engine is in the synergy uhd4 all in 1 camera system? - Answer LED
What are the fluid management options the nanoscope operative arthroscopy system? - Answer Syringe,
gravity, and pump systems
The target used space for the nanoscope operative arthroscopy system include? - Answer Clinic, Procedure Rooms, ORs
The nanoscope operative arthroscopy system differs from its competitors all of the following ways except? - Answer Offering the camera with the smallest diameter
Surgical repair of the lateral ankle ligament of the Atfl is most often accomplished with what procedure? - Answer The modified brostrum gold procedure

Document information

Uploaded on
April 16, 2024
Number of pages
8
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers
$12.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Grademasters
3.8
(46)
Sold
118
Followers
68
Items
2591
Last sold
1 week ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions