• Wrong document? Swap it for free
  • Written by students who passed
  • Immediately available after payment
  • Read online or as PDF
Sell
Where do you study
Your language
Document preview thumbnail
Preview 2 out of 10 pages
Exam (elaborations)

AMT 2 study guide exam 2024/2025

Document preview thumbnail
Preview 2 out of 10 pages

AMT 2 study guide exam 2024/2025 Amtrak Conductors and Engineer are classified as class ______ employees - CORRECT ANSWER-C. [1.103] Should employees in electrified territory be familiar with the location and operation of radios and telephones? - CORRECT ANSWER-Yes [1.204] When using railroad telephone lines or radios, and you hear the word "EMERGENCY" repeated three times, what must be done? - CORRECT ANSWER-All others using the phone line or radio channel must yield immediately. [1.205] All occurrences or conditions which are likely to affect electric Operations must be reported immediately to whom? - CORRECT ANSWER-The Power Director/Train Dispatcher. [1.201] Minimum Approach Distance means? - CORRECT ANSWER-The distance that must be maintained between personnel and or equipment and all exposed energized lines. Minimum Approach Distance is measured between the person or the end of a tool, equipment, or material being used and the exposed energized parts. [1.301] All overhead wires must be considered energized (Live) at all times except? - CORRECT ANSWER-When it is known to be de-energized, tested de-energized and grounded. [1.302] The third rail must be considered energized (live) at all times except? - CORRECT ANSWER-When it is known to be de-energized, tested de-energized and a Third Rail Warning Device is applied. [1.303] Electric engines and Multiple Units (MU) under overhead wires must be considered energized (Live) except? - CORRECT ANSWER-When it is known that all Pantographs are down and Pantograph grounding switches are closed, or overhead wires are deenergized, tested de-energized and properly grounded. [1.501] Can employees touch or remove unidentified dangling wires, trees, or foreign objects in contact with overhead wires or third rail? - CORRECT ANSWER-NO ,employees must take necessary precautions to protect others and equipment and maintain Minimum Approach Distance . [1.206] Conductive material such as steel tape measure, wire, wet or non-rated rope, or linen tape-line containing metallic reinforcement can be used around energized wire, apparatus, equipment, or third rail. True or False? - CORRECT ANSWER-False. [1.114] The Minimum Approach Distance for AMT-2 Qualified Employees whether or not protected by Class A employee against Transmission Wires energized or de-energized and not grounded is? - CORRECT ANSWER-8ft. [Table 1] What is the Minimum Approach Distance for AMT-2 Qualified Employee whether or not protected by a Class A employee against the Catenary, Signal Line, and Utility Wires less than 35000 volts, energized or de-energized and not grounded? - CORRECT ANSWER-3ft. [Table 1] What is the Minimum Approach Distance for AMT-2 Qualified Employees against Transmission Wires for equipment operating in the vicinity of wires energized or deenergized and not grounded? - CORRECT ANSWER-15ft. [Table 1] The Minimum Approach Distance for AMT-2 Qualified Employees against Catenary, Signal Line, Utility Wires Less than 35000 volts for Equipment operating in the vicinity of wires energized or de-energized and not grounded is/ - CORRECT ANSWER-3ft. [Table 1] Personnel and Equipment being provided protection by Class A Employee, wires deenergized, tested de-energized, and grounded will be allowed? - CORRECT ANSWERFull Contact. [Table 1] The Minimum Approach Distance for Unidentified Dangling Wires is? - CORRECT ANSWER-15ft. [Table 1] What is the Minimum Approach Distance while walking over and around energized Third Rail? - CORRECT ANSWER-6 inches. [Table 2] what is the Minimum Approach Distance for AMT-2 Qualified Employees working with conductive tools or equipment around Third Rail? - CORRECT ANSWER-4 feet. [Table 2] The Typical Overhead Wire Profile for the Catenary system starting from The Wire that contacts the Pantograph are? - CORRECT ANSWER


Document information

Uploaded on
April 13, 2024
Number of pages
10
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers
$13.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
StudyCenter1
4.3
(29)
Sold
235
Followers
91
Items
3811
Last sold
1 week ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions

Whoops! We can’t load your doc right now. Try again or contact support.