Dead ends in a system are usually located on a. Loops and/or circular designs b. Tree shaped and Grid designs c. Oval designs d. transmission mains e. Cul de Sac's with return lines - ANSWER-b. Tree shaped and Grid designs An operator may refer to Piezometric elevation, static head, or pressure head as a. horizontal water elevation b. water pressure from a pump c. maximum pressure from a fire hydrant d. vertical water column height - ANSWER-d. vertical water column height A downstream closed sectionalizing valve without pressure reducing valves in the system will have which of the following pressures placed upon it? a. the water surface elevation from the last point where the water is open to the atmosphere b. the back pressures from a downstream point c. the downstream booster pump operation d. the operation of a fire hydrant located immediately downstream of the hydrant - ANSWER-a. the water surface elevation from the last point where the water is open to the atmosphere What is the main purpose of a water storage facility? a. to allow storage reserve during wet periods b. to help maintain adequate pressures throughout the entire system c. to meet needs for fire protection d. to provide sufficient amount of water to average or equalize the daily demands plus provide minimum pressures to fight fires - ANSWER-d. to provide sufficient amount of water to average or equalize the daily demands plus provide minimum pressures to fight fires Electrical demand in a wiring system is determined by the amount of a. Ohms in the entire system b. Voltage a system draws c. Watts consumed d. water pressure in the system - ANSWER-c. Watts consumed Baffling inside a storage facility may be needed to prevent "hot spots" and a. straight through flows b. long contact times with disinfectants c. high chlorine residuals throughout the facility d. high temperatures throughout the storage facility - ANSWER-a. straight through flows

Meer zien Lees minder
Instelling
Water Distribution
Vak
Water distribution









Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
Water distribution
Vak
Water distribution

Documentinformatie

Geüpload op
8 april 2024
Aantal pagina's
8
Geschreven in
2023/2024
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

Water Distribution Test Questions With
Complete Solutions !!

systems are usually laid out in which of the following patterns besides Tree shaped
and Grid designs?
a. Loops and/or circular designs
b. Vertical designs without backflow prevention devices
c. Horizontal lines that flow into open ponds then back into a closed pipe
d. Horizontal lines that flow into underground sumps then back into a closed pipe -
ANSWER-a. Loops and/or circular designs

Dead ends in a system are usually located on
a. Loops and/or circular designs
b. Tree shaped and Grid designs
c. Oval designs
d. transmission mains
e. Cul de Sac's with return lines - ANSWER-b. Tree shaped and Grid designs

An operator may refer to Piezometric elevation, static head, or pressure head as
a. horizontal water elevation
b. water pressure from a pump
c. maximum pressure from a fire hydrant
d. vertical water column height - ANSWER-d. vertical water column height

A downstream closed sectionalizing valve without pressure reducing valves in the
system will have which of the following pressures placed upon it?
a. the water surface elevation from the last point where the water is open to the
atmosphere
b. the back pressures from a downstream point
c. the downstream booster pump operation
d. the operation of a fire hydrant located immediately downstream of the hydrant -
ANSWER-a. the water surface elevation from the last point where the water is open
to the atmosphere

What is the main purpose of a water storage facility?
a. to allow storage reserve during wet periods
b. to help maintain adequate pressures throughout the entire system
c. to meet needs for fire protection
d. to provide sufficient amount of water to average or equalize the daily demands
plus provide minimum pressures to fight fires - ANSWER-d. to provide sufficient
amount of water to average or equalize the daily demands plus provide minimum
pressures to fight fires

Electrical demand in a wiring system is determined by the amount of
a. Ohms in the entire system

, b. Voltage a system draws
c. Watts consumed
d. water pressure in the system - ANSWER-c. Watts consumed

Baffling inside a storage facility may be needed to prevent "hot spots" and
a. straight through flows
b. long contact times with disinfectants
c. high chlorine residuals throughout the facility
d. high temperatures throughout the storage facility - ANSWER-a. straight through
flows

Chlorine may be added to water in a continuous, slug, and/or the _______ method to
initially disinfect a pipeline?
a. segmented
b. tablet
c. low dose
d. air injection - ANSWER-b. tablet

Wear rings in a centrifugal pump are designed to
a. prevent excessive internal water circulation between the suction and discharge
sides of a pump
b. prevent wear of the impeller and inside case
c. allow excessive internal water circulation to occur between the suction and
discharge
d. both a & b are correct, but not c - ANSWER-d. both a & b are correct, but not c

Packing ring notches in a centrifugal type pump should be ______ when placed in
the stuffing box?
a. water tight
b. staggered 90º
c. made of rubber not metal
d. heated - ANSWER-b. staggered 90º

Eighty parts per billion (80 ppb) is equal to which of the following?
a. 8 ppm
b. 0.8 mg/L
c. 0.08 mg/L
d. 80 mg/L - ANSWER-c. 0.08 mg/L

A mass of concrete placed at bends and valve structures to prevent pipeline
movement is commonly called a
a. thrust block
c. curb stop
b. corp stop
d. service block - ANSWER-a. thrust block

What is the main difference between surface and groundwater contamination?
a. groundwater takes longer to recover after contamination
b. groundwaters are less susceptible to contamination
c. surface waters take longer to recover

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
IMORA West Virginia University
Bekijk profiel
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
196
Lid sinds
2 jaar
Aantal volgers
77
Documenten
5080
Laatst verkocht
6 dagen geleden

4.4

69 beoordelingen

5
49
4
8
3
8
2
1
1
3

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via Bancontact, iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo eenvoudig kan het zijn.”

Alisha Student

Veelgestelde vragen