1|Page



MRSO MOCK EXAM 2024 WITH ACTUAL
CORRECT QUESTIONS AND VERIFIED
DETAILED RATIONALES ANSWERS BY
EXPERTS |FREQUENTLY TESTED
QUESTIONS AND SOLUTIONS |ALREADY
GRADED A+ |NEWEST |LATEST UPDATE |
GUARANTEED PASS



The transmission of radiofrequency waves will cause what?

A. Peripheral nerve stimulation
B. Patient heating
C. Magnetohydrodynamic effect
D. Vertigo

B. Patient heating

Unsafe electrical devices in patients should be restricted from which of the following?

A. Entering Zone 2
B. Entering Zone 1
C. Crossing the 5-gauss line
D. Crossing the 10-gauss line

C. Crossing the 5-gauss line

Which of the following is used to measure patient heating?

A. Patient heating ratio
B. Specific energy resonance
C. Set absorption ratio
D. Specific absorption rate

D. Specific Absorption Rate

What type of MRI unit uses many bricks of magnets to produce a strong static field?

,2|Page


A. All of choices
B. Resistive magnet
C. Permanent Magnet
D. Superconducting magnet

C. Permanent Magnet

Which of the following are units of measurements for static magnetic fields?

A. Decibels
B. Tesla
C. Gauss
D. Tesla and Gauss

D. Tesla and Gauss

When does resonance occur?

A. When the patient is placed in isocenter and only experiences the static magnetic field
B. When the radiofrequencies transmitted match the precessional speed of hydrogen.
C. When the radiofrequencies are different than the precessional speed of hydrogen.
D. When the radiofrequency is transmitted at 42.6 MHz

B. When the radiofrequencies transmitted match the precessional speed of hydrogen.

An object that produces a weak repulsive force in presence of a strong magnetic field is called what?

A. Diamagnetic
B. Paramagnetic
C. Superparamagnetic
D. Ferromagnetic

A. Diamagnetic

What does the image of MR with a red circle and slash through it represent?

A. MR Unsafe
B. MR Conditional
C. MR Safe
D. MR Compatible

A. MR Unsafe

Where is Cryogen found?

A. In the MR unit
B. In zone 3
C. In the equipment room
D. In the quench vent

,3|Page


A. In the MR Unit

Normal kidneys should excrete all gadolinium contrast from a patient how quickly?

A. 48 hours
B. 24 hours
C. 6 hours
D. 12 hours

B. 24 hours

The noise hear in MRI is caused by which of the following?

A. Lorentz Force
B. The antenna effect
C. Larmor force
D. Ohms Force

A. Lorentz Force

The speed that it takes a gradient coil to reach maximum strength is called what?

A. Slew rate
B. Rise time
C. Spatial gradient
D. Maximum gradient peak

B. Rise Time

What is the purpose of a cryogen?

A. To reduce the overall noise produced during acquisition
B. To reduce the heating produced in the MRI unit during each acquisition.
C. To eliminate the resistance of electrical current in the coils of wire that produce the static magnetic
field
D. To allow the MRI unit to function at the fast speeds necessary to achieve an MRI image.

C. To eliminate the resistance of electrical current in the coils of wire that produce the static magnetic
field

How loud are noised restricted to in MRI when considering the A- weighting?

A. 69 decibels
B. 99 decibels
C. 120 decibels
D. 40 decibels

B. 99 decibels

, 4|Page


Which of the following are not recommended by the ACR guidance document in MR safety 2013 in
proper scanning of a patient?

A. Metal detector
B. Patient Gown
C. Written screening sheet
D. Ferromagnetic detection system

A. Metal detector

What type of MRI unit uses a coil of a wire with a current running through it and a cryogen to produce a
strong magnetic field?

A. Resistive magnet
B. All of the choices
C. Permanent Magnet
D. Superconducting Magnet

D. Superconducting Magnet

Contrast media will do what to tissue?

A. Increase T2 relaxation times and decrease T1 relaxation times.
B. Shorten T1 relaxation times
C. Shorten T2 relaxation times
D. Shorten T1 and T2 relaxation times

D. Shorten T1 and T2 relaxation times

Where are the gradient coils found?

A. In zone 3
B. Under the patient
C. Surrounding the patient
D. At the control panel on the MR unit

C. Surrounding the patient

The process of releasing cryogen from the MR unit is called?

A. Valve opening
B. Quench
C. Depressurization
D. Release

B. Quench

The allowable maximum strength of the gradient coils is called what?

Document information

Uploaded on
April 6, 2024
Number of pages
40
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers
$15.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Drmserpi
4.6
(216)
Sold
95
Followers
32
Items
2231
Last sold
1 week ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions