IRC Building Code Questions with
correct Answers 2024
In Seismic Design Categories D0, D1, and D2, _____ stone masonry walls shall
not be used. - -Rubble

R404.1.1.1 Masonry foundation walls.

-In Seismic Design Categories Do, D1 and D2, foundations with stem walls
shall be provided with a minimum of one No. ___ bar within 12 inches of the
top of the wall and one No. ___ bar located 3 to 4 inches from the bottom of
the footing. - -#4
#4

R403.1.3.1 Foundations with stemwalls

-The grade away from foundation walls shall fall a minimum of ___ inches
within the first ____ feet. - -6 in.
10 ft.
(Read exception)

R401.3 Drainage

-In flood hazard areas, enclosed areas below the design flood elevation shall
be used sole for:
1._____
2._____
3._____ - -Parking of vehicles
Building access or
Storage

R322.3.5 Enclosed areas below design flood elevation.

-Address number shall be a minimum of ___ inches high with a minimum
stroke of ____inch. - -4 in.
1/2 in.

R319.1 Address numbers

-Protection of wood and wood based products from ___ shall be provided by
the use of naturally durable wood or wood that is preservative treated. - -
Decay

R317.1 Location required

, -Dwelling Units in two-family dwellings shall be separated from each other
by wall and/or floor assemblies having not less than ___-hour fire resistive
rating. - -1 hour

R302.3 Two family dwellings

-In areas where the probability of termite infestation is "very heavy", the
clearance between foam plastics installed above grade and exposed earth
shall be at least ____ inches. - -6 in.

R318.4 Foam plastic protection

-A thermal barrier is not required for foam plastic insulation in an attic that
is entered only for purposes of ____ or ____. - -Repairs or maintenance

R316.5.3 Attics

-Foam plastic shall be separated from the interior of a building by an
approved ____ ____ of minimum ____- inch gypsum wallboard. - -Thermal
barrier
1/2 in.

R316.4 Thermal barrier

-All exterior footings shall be placed at least ___ inches below the
undisturbed ground surface. - -12 in.
(Where applicable, the dept of footings shall also conform to R403.1.4.1 -
R403.1.4.2)

R403.1.4 Minimum length

-The top surface of footings shall be level. The bottom surface of footings
shall not have a slope exceeding ____ unit vertical in ____ units horizontal. - -
1:10
R403.1.5 Slope

-Wood sill plates shall be anchored to the foundation with anchor bolts
spaced a maximum of ____ feet on center. - -6 ft.

R403.1.6 Foundation anchorage

-Foundation anchor bolts shall be at least ___ inch in diameter and shall
extend a minimum of ___ inches into the concrete or grouted cells of
concrete masonry units. - -1/2 in.
7 in.

, R403.1.6 Foundation anchorage

-Isolated hollow masonry piers shall have a minimum nominal thickness of
____ inches. - -8 in.
R404.1.9 Isolated masonry piers.

-Hollow masonry piers shall be capped with ____ inches of solid masonry or
concrete or a masonry cap block. - -4 in.
As an alternative, the cavities of of the top course must be filled with
concrete or grout.

R404.1.9.1

-The studs used in wood foundation walls shall be ____-inch by ____-inch
members. - -2-inch by 6-inch

R404.2.2 Stud size

-Wood sill plates shall be a minimum of ____-inch by ____-inch nominal
lumber. - -2-inch by 4-inch

R404.3 Wood sill plates

-Perforated foundation drains shall be surrounded with an approved ____
____. - -Filter membrane
(or the filter membrane shall cover the washed gravel or crushed rock
covering the drain)

R405.1 Concrete or masonry foundations

-The minimum net area of ventilation openings shall be not less than ____
square foot for each ___ square feet of under-floor space. - -1 sq. ft. for each
150 sq. ft.

R408.1 Ventilation

-Ventilation openings in under-floor spaces are not required where the
ground is covered with a continuous ____ vapor retarder and the joints
overlap at least ____ inches. - -Class I
6

R408.3 Unvented crawl space

-The minimum required floor access opening to all under-floor spaces shall
be ____ inches by ____ inches. - -18 inches by 24 inches.

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
AccurateScores Not yet listed
View profile
Follow You need to be logged in order to follow users or courses
Sold
536
Member since
3 year
Number of followers
336
Documents
15229
Last sold
5 days ago

3.7

111 reviews

5
50
4
17
3
18
2
11
1
15

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can immediately select a different document that better matches what you need.

Pay how you prefer, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card or EFT and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions