EPA 608 Type II Sample Test Questions. Before charging a new system with refrigerant, what should be done? Pressurize with nitrogen (classified as an inert gas) and leak Which refrigerant can be used for leak detection as a trace gas and pressurized with nitrogen? R-22 What tools can you use to find general area of leaks and pinpoint leaks? a. Soap bubbles. b. Look for oil residue c. Electronic or ultrasonic leak detector will provide the general area of the leak d. Refrigerant dye c. Electronic or ultrasonic leak detector will provide the general area of the leak Traces of oil around a sight glass inlet fitting of a refrigeration system might be the indication of: a. A leak b. Excessive oil in the system c. An overcharge d. A restriction at the TXV a. A leak Describe ways you can visually look for leaks. a. Using soap bubbles b. Looking for traces of oil c. Excessive superheat, caused by low refrigerant charge d. All the above d. All the above Type II classification, as identified by EPA, applies to what equipment? a. Small appliances with five (5) pounds of refrigerant or less b. Refrigerators, freezers, and vending machine appliances c. Low pressure appliances d. Split air conditioning equipment with five (5) pounds of refrigerant or more d. Split air conditioning equipment with five (5) pounds of refrigerant or more

Content preview

EPA 608 Type II Sample Test Questions.
Before charging a new system with refrigerant, what should be done?

Pressurize with nitrogen (classified as an inert gas) and leak

Which refrigerant can be used for leak detection as a trace gas and pressurized
with nitrogen?

R-22

What tools can you use to find general area of leaks and pinpoint leaks?
a. Soap bubbles.
b. Look for oil residue
c. Electronic or ultrasonic leak detector will provide the general area of
the leak
d. Refrigerant dye

c. Electronic or ultrasonic leak detector will provide the general area of
the leak

Traces of oil around a sight glass inlet fitting of a refrigeration system might be
the indication of:
a. A leak
b. Excessive oil in the system
c. An overcharge
d. A restriction at the TXV

a. A leak

Describe ways you can visually look for leaks.
a. Using soap bubbles
b. Looking for traces of oil
c. Excessive superheat, caused by low refrigerant charge
d. All the above

d. All the above

Type II classification, as identified by EPA, applies to what equipment?
a. Small appliances with five (5) pounds of refrigerant or less
b. Refrigerators, freezers, and vending machine appliances
c. Low pressure appliances
d. Split air conditioning equipment with five (5) pounds of refrigerant
or more

d. Split air conditioning equipment with five (5) pounds of refrigerant
or more

, What are the leak repair requirements for comfort cooling appliances and commercial Appliances
containing 50 lbs. or more of refrigerant?
a. Must be repaired if leak rate exceeds 15% in comfort cooling appliances.
b. Must be repaired if leak rate exceeds 35% in all commercial and industrial
process refrigeration\
c. a and b
d. None of the above

c. a and b

What type of refrigerant was the most common before outlawing CFCs and
HCFCs?
a. R-12
b. R-22
c. R-500
d. R-134A

b. R-22

The required level of evacuation for recovery equipment manufactured after
November 15, 1993, on a system containing less than 200 pounds of R-12
refrigerant is:
a. 0 inches Hg
b. 4 inches Hg
c. 10 inches Hg
d. 15 inches Hg

c. 10 inches Hg

What is the purpose of the filter drier and when should it be changed?
a. To filter the oil. Change every year.
b. To remove moisture from the refrigerant, replace on a routine basis
or anytime a system is opened
c. Cleans the air. Replace monthly
d. Dryer's air filters. Replace yearly

b. To remove moisture from the refrigerant, replace on a routine basis or anytime a system is opened

Industrial process and commercial refrigeration equipment with over 50 pounds
of refrigerant with an annual leak rate of ___ % requires repair under EPA
regulations.
a. 0
b. 15
c. 35
d. 50

c. 35

Document information

Uploaded on
March 21, 2024
Number of pages
10
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers
$13.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
ACADEMICAIDSTORE
4.1
(176)
Sold
1224
Followers
894
Items
12820
Last sold
1 month ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions