• Wrong document? Swap it for free
  • Written by students who passed
  • Immediately available after payment
  • Read online or as PDF
Sell
Where do you study
Your language
Document preview thumbnail
Preview 2 out of 15 pages
Exam (elaborations)

Journeyman Plumbing Test (Texas) Questions and Answers 100% Solved

Document preview thumbnail
Preview 2 out of 15 pages

Journeyman Plumbing Test (Texas) Questions and Answers 100% Solved Access (to) - answerThat which enables a fixture, appliance or equipment to be reached by ready access or by a means that first requires the removal or movement of a panel, door or similar obstruction. Air Break (Drainage System) - answerA piping arrangement in which a drain from a fixture, appliance or device discharges indirectly into another fixture, receptacle or interceptor at a point below the flood level rim and above the trap seal. Air Gap (Drainage System) - answerThe unobstructed vertical distance through the free atmosphere between the outlet of the waste pipe and the flood level rim of the receptacle into which the waste pipe is discharging. The distance between the waste pipe outlet and the flood level rim of the receptor must be at least twice the diameter of the indirect waste pipe. Air Gap (Water Distribution System) - answerThe unobstructed vertical distance through the free atmosphere between the lowest opening from any pipe or faucet supplying water to a tank, plumbing fixture or other device and the flood level rim of the receptacle. Appliance - answerAny apparatus or device that utilizes a fuel or a raw material as a fuel to produce light, heat, power, refrigeration or air conditioning that compresses fuel gases. Backflow - answerPressure created by any means in the water distribution system, which by being in excess of the pressure in the water supply mains causes a potential backflow condition. Backsiphonage - answerThe backflow of potentially contaminated water into the potable water system as a result of the pressure in the potable water system falling below atmospheric pressure of the plumbing fixtures, pools, tanks or vats connected to the potable water distribution piping. Backflow Connection - answerAny arrangement whereby backflow is possible. Backflow Preventer - answerA backflow prevention assembly, a backflow prevention device or other means or method to prevent backflow into the potable water supply. Bathroom Group - answerA group of fixtures consisting of a water closet, lavatory, bathtub or shower, including or excluding a bidet, an emergency floor drain or both. Such fixtures are located together on the same floor level. Branch Interval - answerA vertical measurement of distance, 8 feet (2438 mm) or more in developed length, between the connections of horizontal branches to a drainage stack. Measurements are taken down the stack from the highest horizontal branch connection. Branch Vent - answerA vent connecting one or more individual vents with a vent stack or stack vent. Building Drain - answerThat part of the lowest piping of a drainage system that receives the discharge from soil, waste and other drainage pipes inside and that extends 30 inches (762 mm) in developed length of pipe beyond the exterior walls of the building and conveys the drainage to the building sewer. Code - answerThese regulations, subsequent amendments thereto or any emergency rules or regulations that the administrative authority having jurisdiction has lawfully adopted Combination Waste and Vent System - answerA specially designed system of waste piping embodying the horizontal wet venting of one or more sinks, lavatories, drinking fountains or floor drains by means of a common waste and vent pipe adequately sized to provide free movement of air above the flow line of the drain. Pipe Material / Max Horizontal Bracing / Max Vertical Bracing - answerABS / 4ft / 10ft Cast-Iron / 5ft / 15ft Copper Tubing (1 1/4 or smaller) / 6ft / 10ft Copper Tubing (1 1/2 or larger) / 10ft / 10ft PEX / 32in / 10ft PVC / 4ft / 10ft Common Vent - answerA vent connecting at the junction of two fixture drains or to a fixture branch and serving as a vent for both fixtures. Conductor - answerA pipe inside the building that conveys stormwater from the roof to a storm or combined building drain. Contamination - answerAn impairment of the quality of the potable water that creates an actual hazard to the public health through poisoning or the spread of disease by sewage, industrial fluids or waste. Cross Contamination - answerAny physical connection or arrangement between two otherwise separate piping systems, one of which contains portable water and the other, either water of unknown or questionable safety or stream, gas or chemical, whereby their exists the possibility for flow from one system to the other, with the direction of flow depending on the pressure differential between the two systems ("B


Document information

Uploaded on
March 7, 2024
Number of pages
15
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers
$12.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Brainbarter
3.6
(58)
Sold
369
Followers
159
Items
22959
Last sold
2 weeks ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions

Whoops! We can’t load your doc right now. Try again or contact support.