NICET LEVEL 1 All Answers Rated A+
NICET LEVEL 1 All Answers Rated A+ 4 wires what is the maximum number of 14 AWG RHH conductors which can be installed in 1/2 rigid metal conduit? 3.5'-48" to the actuator pull station? 1 flash per second Which of the following would be an appropriate mounting height for a What is the minimum flash rate for a visible notification device? 90" to the top of the device devices? What is the minimum mounting height for audible notification Such that the entire lens is not less then 80" notification devices? Voltage=Current X Resistence What is the minimum mounting height for visible What is the formula for Ohm's Law Put your meter in series with the circuit Semi-annually When using your mult-meter to measure, you must: Waterflow devices shall be tested with that frequency? Annually With what frequency shall ionization smoke detectors be given a functional test? 24 hours in normal operation, 5 minutes in alarm proprietary signaling system? Shunt type What are the standby power requirements for a Which of the following is a type of auxiliary protective signaling system? A UL listed central station A receiver located at an unlisted monitoring facility A fire department or communications center Remote station signaling systems are permitted to send signals to: 600V Non-power limited fire alarm cable shall have an insulation rating of: 20,000 CFM HVAC system serving a single floor 15,000 CFM HVAC system serving 3 floors 20,000 CFM HVAC system serving 2 floors detectors on supply and return? Group A, E, F Which of these HVAC systems would require duct According to the IBC, which of the following use Groups require visual notification? Every 4 hours Digital Alarm communicator transmitters (DACT) which use call forwarding to the DACR shall be tested with what frequency? True When connecting 4 wires smoke detectors to a fire alarm system, the power conductors shall be monitored for integrity. Smoke detectors shall be permitted to use 30 foot spacing as a guide true regarding smoke detector spacing? A slope of greater than 1 in 8 A slope ceiling is defined as: Which of the following is Fire alarm control equipment shall be protected with an automatic detector when not in continuously occupied areas Positive alarm sequence requires the approval of the AHJ FPLP cable may be substituted with CMP cable Alarm signal Trouble signal Which of the following is true? For sprinkler systems what type of signal is fire pump running? A dedicated branch circuit consider a fire alarm system with primary power source as commercial light power. what type of branch circuit is permitted to supply the fire alarm system? Multimeter what is type of meter is typically used to measure current in a fire alarm system
Written for
- Institution
- NICET LEVEL
- Course
- NICET LEVEL
Document information
- Uploaded on
- February 26, 2024
- Number of pages
- 8
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
-
nicet level 1 all answers rated a
Also available in package deal