Journeyman Electrician (2024Nec) Questions With Correct Answers

Document preview thumbnail
Preview 2 out of 10 pages

Conductors with _____ marked on the insulation are NOT approved for use in a wet location. a. THW b. THHW c. THHN d. THWN - Answer THHN As shown in Table 310.104(A), conductors with THHN insulation are approved for use in dry and damp locations only and conductors with THWN, THHW, and THW insulation are recognized for use in dry and wet locations. Given: A one-family dwelling unit with a demand load of 200 amperes is supplied with a 120/240 volt, single-phase, electrical system from the local utility company. What is the MINIMUM size aluminum THW conductors required for use as service-entrance conductors for this residence? a. 1/0 AWG b. 4/0 AWG c. 3/0 AWG d. 2/0 AWG - Answer 4/0 AWG Section 310.15(B)(7)(1) permits one-family dwelling 120/240 volt, single-phase, service-entrance conductors to be sized at an ampacity of not less than 83% of the service rating. Therefore, 200 amperes x 83% = 166 amperesTable 310.15(B)(16) indicates size 4/0 AWG THW aluminum conductors with an allowable ampacity of 180 amperes should be selected for this dwelling. Where a 150 kVA, single-phase transformer having a secondary voltage of 120/240 is installed at a multi-family dwelling, the full-load current rating, in amperes, of the secondary is _____. a. 625 amperes b. 265 amperes c. 526 amperes d. 1250 amperes - Answer 625 ampreres To find the full-load current rating of the single-phase transformer apply the single-phase current formula as shown: I = (150 kVA x 1000) / 240 volts = 15,000/240 = 625 amperes Which one of the following listed circuit breakers is NOT a standard ampere rating?a. 75 amperes b. 90 amperes c. 110 amperes d. 225 amperes - Answer 75 amperes Table 240.6(A) illustrates the standard ampere ratings for fuses and circuit breakers. A circuit breaker with an ampere rating of 75 amperes is not a standard ampere rating. The MINIMUM length of free conductor to be left at each junction box for the purpose of splicing conductors, or making connections to luminaires or devices shall be _____ .a. 4 inches b. 10 inches c. 8 inches d. 6 inches - Answer 6 inches As per Section 300.14 at least 6 in. of free conductor is to be left at each junction box for splices or the connection of luminaires or devices. The intent of this rule is to ensure enough conductor slack for the terminal connections or splices to be made easily. In general, overhead service-drop conductors shall NOT be smaller than _____. a. 2 AWG copper b. 4 AWG copper c. 6 AWG copper d. 8 AWG copper - Answer d. 8 AWG copper Section 230.23(B) requires overhead service-drop conductors to be not smaller than 8 AWG copper or 6 AWG aluminum or copper-clad aluminum. Do not get service-drop conductors, the overhead conductors between the utility electric supply system and the service point, confused with the service-entrance conductors, the conductors from the service point from the utility company to the service disconnecting means. When a galvanized eye-bolt is to be used as the point of attachment for an electrical service, the NEC requires the eye-bolt to be installed NOT less than _____ above finished grade. a. 8 ft. b. 10 ft. c. 12 ft. d. 15 ft. - Answer 10 Ft The intent of Section 230.26 is to provide adequate vertical clearance of the conductors and prevent physical damage to the conductors and prevent persons from making accidental contact with the conductors which may create a shock hazard or electrocution. In no case shall the point of attachment of the service-drop conductors to be less than 10 ft. above finished grade. Why is electrical continuity required for metallic conduit? a. To reduce voltage drop. b. To limit galvanic corrosion. c. To establish an effective ground-fault path and facilitate the operation of the overcurrent protective device. d. To reduce electrolysis. - Answer To establish an effective ground-fault path and facilitate the operation of the overcurrent protective device.


Document information

Uploaded on
February 7, 2024
Number of pages
10
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers
$11.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Exampool
3.9
(32)
Sold
224
Followers
148
Items
3589
Last sold
13 hours ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions

Whoops! We can’t load your doc right now. Try again or contact support.