(Summary) Appian Credential Study Guide, With Complete Verified Solution 100% Pass Guarantee
(Summary) Appian Credential Study Guide, With Complete Verified Solution 100% Pass Guarantee Deny Users who can explicitly not access the application. Viewer Users who can view the application in Tempo for actions and feeds. Editor Users who can add objects to the application and make changes on the design side. Administrator Users who can do everything to the application, including publish, export, and delete. Precedent Any object that an object relies on to function properly. XML Schema Definition (XSD) CDTs can be downloaded as ______ files. T/F: CDTs can reference other CDTs. True CDT (Custom Data Type) A logical grouping of related data. Palette Provides categories of nodes. Canvas Area where nodes are placed. Toolbar Icons for creating a new model, saving, printing, and more. T/F: All objects within process model folders inherit the folder security. False Which Process Modeler view do we use when creating a High-Level Diagram? Analyst View What is the keyboard shortcut to switch between the connector and the selector? Shift Key T/F: Subfolders inherit the security of their parent folders. True Validation Built using an if() statement, this property ensures that users enter data that meets certain criteria. Interface Inputs These objects are variables that can be used to pass data to or from a form when testing. Choice Labels & Choice Values These properties are used to define options and data saved for dropdown, checkbox, and radio button fields. Submit Button This type of button will complete the form and move to the next node in a process. Form Layout This type of layout is used in an interface when users need to input data using a User Input Task. What information about the process can be defined in the Process Properties window? Process Variables Process Display Name Alerts T/F: You must set a process variable as a parameter in order to pass data into the process when it starts. True Which process model security role allows a user to start a process, but not see any data from the process in records or reports? Initiator Which process property refers to the user who started the process? Initiator General Tab This tab allows you to define basic properties such as the process model name and description. Variables Tab This tab defines data that can be used throughout the length of the process. Alerts Tab In this tab, you can configure where error messages should go. Data Management Tab This tab determines how long process data should be held in memory. pp! This prefix is used to define properties of the process, such as the initiator. ac! This prefix references all variables that are defined as a node input. These variables only exist through while the node is still active. pv! These variables exist throughout the length of the process, and node input variables can save into these. T/F: Activity Class Parameter values must be saved into a process variable in order to use the data in later nodes within the process. True From which tabs can you create activity class parameters in a task? Forms Data--Inputs T/F: Appian always saves the result of input variables before outputs within a user input task. False Activity Chaining This allows users to view multiple forms one after another without having to click the tasks tab. Start Form If this object is defined, the process will not start until a user provides information within a form and passes the data to parameterized process variables. Alerts Any issues that cause a process to pause by exception can be found here. Unpublish the Application This is the best way to quickly hide all actions within a certain application. T/F: Any forms filled out in Tempo will automatically update the monitor view of a process instance. False T/F: Activity chaining allows users to view two forms consecutively without having to navigate to the tasks tab. True Where can you access alerts from a process? In Runtime Data (/designer) at the Alerts link at the top Which of the following must be completed before an action will display in Tempo? An action must be defined in the application The process model must be published The application must be published Parameter In terms of a sub-process, this means that the process variable is expecting to receive a value from the parent model. Asynchronous If a sub-process is configured to run in this way, the sub-process node will complete immediately after the sub-process has started. Pass as Reference This option means that changes to process variables will be simultaneously updated in both the parent and sub-process. T/F: You should always test your sub-process independently of the main process before connecting them together. True T/F: Any updates made to the variable in either the parent process or sub-process will be automatically passed to the other process. True T/F: You should never pass a CDT as reference. True What does it mean if the sub-process is set to run synchronously? The parent process will wait for the sub-process to complete before continuing T/F: You can only pass a variable as reference within an Asynchronous process model. False T/F: If you pass a variable as reference, the value won't change while the sub-process is active. False AND This type of gateway will wait for all incoming flows to complete before continuing and does not require any configuration. OR This gateway has one incoming flow and will execute one or more outgoing flows based on all true conditions. XOR This gateway has one incoming flow and will execute one outgoing flow based on a true condition. Complex This gateway can be configured to require that either specific, named inbound paths complete or a minimum number of inbound paths compete before it continues. Which type of gateway will always execute exactly one output? XOR T/F: An AND gateway waits for all incoming flows to arrive before continuing. True T/F: An AND gateway executes all outgoing flows simultaneously. True T/F: An AND gateway allows you to use an expression to determine which outgoing flows to execute. False T/F: An AND gateway should only contain one incoming flow. False How many nodes can be spawned using MNI? 1000 T/F: Multiple Node Instances can only be used within Script Tasks. False What security role is required for users to be able to upload and download documents, but not modify security? Editor T/F: Each document has a unique ID that can be saved into a CDT for reference. True What is the top object in the document management hierarchy? Knowledge Center Stored Values This output on a Write to Data Store Entity might be used to return the identifier of a row from a database. Data Store Entity and Identifiers These two inputs are required to specify which data should be deleted in the Delete from Data Store Entity Smart Service. Auto-Generate the Primary Key This property should be set on a CDT to ensure that the database will generate a unique ID when inserting a row of new data. T/F: If auto-generate was selected for the primary key in the CDT, the database will automatically create a new row if no ID is provided.
Document information
- Uploaded on
- February 4, 2024
- Number of pages
- 14
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers