Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 3 out of 24 pages
Exam (elaborations)

NYC MASTER ELECTRICIAN EXAM ALREADY PASSED TEST | VERIFIED

Document preview thumbnail
Preview 3 out of 24 pages

NYC MASTER ELECTRICIAN EXAM ALREADY PASSED TEST | VERIFIED Type ____ is multiconductor cable identified for use as underground service entrance cable. - ANSWER Type USE cable Knife switch rated for more than 1200 Amps at 250Volts or less - ANSWER Can be used only as isolating switch, shall not be opened under load Track lighting with outlets in a bathroom is not allowed because ? - ANSWER Track lighting has receptacle Where internal combustion engines are used as the prime motor, an on site fuel supply shall be provided with an on premise fuel supply sufficient for not less than ____ hours full demand operation of the system - ANSWER 6 hours Fixed in place X-ray equipment properly supplied by a branch circuit rated at not over ____ amperes shall be permitted to be supplied through a suitable attachment plug cap and hard service cable cord. - ANSWER 30 Amps Where skin effect exist the ferromagnetic envelope shall be bonded at ____. - ANSWER Both ends GFCI protection at a carnival is not required for equipment at circuit if the receptacle is of the ____type. - ANSWER Locking The maximum voltage drop from service point to the last over-current device in a dwelling unit? - ANSWER 4% Which of the following statements best describe the grounding requirement for central vacuum outlet - ANSWER Accessible non current carrying metal parts are required to be connected to an equipment grounding conductor. In healthcare facilities, patient bed receptacles located in general care areas shall be supplied by at least two branch circuits, which ____permitted to originate from two separate transfer switches on the emergency system - ANSWER Are permitted Patient care areas of healthcare facilities ____ areas such as business offices, corridors, lounges ,day rooms, or similar areas - ANSWER Do not include The patient care area is any portion of the healthcare facility where patients are intended to be ____or ____. - ANSWER Examined or treated Each general care area patient bed location in a healthcare facility must be provided with four ____ or ____ duplex receptacles - ANSWER Single or two A hospital is a building or portion thereof used for medical, psychiatric,obstetrical , or surgical, care on a 24 hour basis of ____ or more patients - ANSWER Four Where installed to reduce electrical noise for electronic equipment, electrical continuity of the metal raceways shall not be required and metal raceway can terminate a (an) ____ nonmetallic fitting or spacer on electronic equipment - ANSWER Listed fitting Feeder and branch circuit conductors within ____ inches of a Ballast shall have an insulation temperature rating not lower than 90°C (194°F) unless supplying a luminaiere marked as suitable for a different insulation temperature - ANSWER 3 inches Manufactured wiring systems constructed with type MC cable shall be supported and secured at intervals not exceeding ____ ft. - ANSWER 6 ft Where a main bonding jumper or a system bonding jumper is a screw only the screw shall be identified with a ____ that shall be visible with the screw installed - ANSWER Green finish Plug fuses a 15 amperes and lower rating shall be identified by a ____ configuration of the window, cap, or other prominent part to distinguish them from fuses of higher ampere rating - ANSWER Hexagon The load for household electric clothes dryer's in a dwelling unit(s) shall be either ____ watts (volt-amperes) or the nameplate rating, which ever is larger, for each dryer served ? - ANSWER 5000 watts Service conductors installed as unjacketed multiconductor cable shall have a minimum clearance of ____ windows that are designed to be opened, doors, porches, stairs fire escape or similar locations. - ANSWER 3 ft (36 inches) —— Cartridge fuses of the renewable type shall be permitted to be used only for replacement in existing installation is where there is no evidence of over-fusing or tampering. - ANSWER Class H Branch circuit conductors within ____inches of the ballast shall have an insulation temperature rating not lower it 90°C 194°F - ANSWER 3" inches The minimum radius of a field bend on trade size 1 "1/4 RMC is ____. - ANSWER 8 In a dwelling unit which appliance is allowed to have a 24"inch cord with Attachment ground plug ? - ANSWER Combination range hood/microwave oven Type 3 Surge Protective devices can be installed on the load side of a branch circuit overcurrent device up to the equipment ____ the type 3 SPD connection must be a minimum 30'ft of conductor a distance from the service or separately derived system disconnect - ANSWER Included in the manufactures instructions Which flexible cable is Allowed to be used for electric vehicle charging station 300 Volts ? - ANSWER EVJ


Document information

Uploaded on
February 1, 2024
Number of pages
24
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers
$12.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
LECTHEODORE
5.0
(9)
Sold
20
Followers
21
Items
1841
Last sold
1 year ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions

Whoops! We can’t load your doc right now. Try again or contact support.