NCLE Advanced Certification Exam Questions and Answers Already Passed The answer is D. The posterior optical zone will directly affect the lens to cornea relationship of a rigid gas permeable lens. If the posterior optical zone is steepened, it will increase the sagittal depth. If it is flattened, it will decrease the sagittal depth. Changing the power, which is accomplished by changing the anterior optical zone, will not affect the sagittal depth of the lens, nor will changing its edge design. - Answer ️️ -1. The sagittal depth of a rigid gas permeable contact lens can be altered without changing the diameter by: A. Changing the power B. Changing the edge design C. Changing the radius of curvature of the anterior optical zone D. Changing the radius of curvature of the posterior optical zone The answer is A. A lens is truncated by removing a segment of the lower edge of a contact lens. This creates a straight edge that interacts with the lower lid and aids in lens positioning. Of the lens designs listed in the question, the only one that requires precise positioning of its optical portions is a translating bifocal lens. - Answer ️️ -2. A truncation is used on a rigid gas permeable contact lens to help enhance the performance of which type of design? A. Bifocal B. Aphakic C. Bitoric D. Keratoconus The answer is B. A lenticular or myoflange design will decrease the mass of an aphakic lens as well as increase the edge profile, which allows it to interact more with the upper lid and aid in positioning of the lens. - Answer ️️ -3. The mass of an aphakic rigid gas permeable contact lens can be reduced by making the lens design: A. Spherical B. Lenticular C. Tricurve D. Aspheric The answer is B. Increasing the optical zone diameter and increasing the overall lens diameter will both tighten and steepen the relationship of the lens to the cornea. Decreasing the optic zone diameter will serve to flatten and loosen the lens to cornea relationship. Using a prism-ballasted lens design will not affect the lens to cornea relationship as it relates to sagittal depth. - Answer ️️ -4. In order to tighten the fit of a rigid gas permeable lens you can: I. Increase the optical zone diameter 2. Decrease the optical zone diameter 3. Increase the overall lens diameter 4. Use a prism ballasted lens design A. 3 only B. 1&3 C. 2 only D. 2&3 The answer is D. A hyperflange will decrease edge thickness as well as lens awareness . Aspheric peripheral curves change the posterior design of the lens but do not reduce edge thickness. A higher Dk material will not change the overall lens edge thickness. A myoflange will actually add thickness to the lens edge and is used for high plus lenses not high minus lenses. - Answer ️️ -5. A high minus rigid gas permeable lens will be thin centrally with relatively thick edges. To reduce the edge thickness, and increase overall comfort, use: A. Aspheric peripheral curves B. A myoflange C. A higher Dk material D. A hyperflange The answer is C. One would rarely polish or attempt to manipulate the central posterior surface of a rigid lens. Applying polishing pressure to the mid-peripheral and the peripheral anterior surface would add plus power. Applying polishing pressure to the central anterior surface would add minus power. - Answer ️️ -6. To add minus power to a rigid contact lens with a rotating modifying spindle, one would: A. Polish the posterior surface of the rigid lens B. Polish the mid peripheral anterior surface C. Polish the central anterior surface D. Polish the peripheral anterior surface The answer is A. The keratometer readings indicate the need for a spherical back surface, which would rule out the use of a bitoric lens. A soft spherical lens would not correct the moderate amount of refractive astigmatism that is present, nor would the spherical rigid gas permeable lens. A front surface toric RGP would best meet this patient's needs since it has a spherical back surface, but has a toric front surface which would correct the residual astigmatism. - Answer ️️ -7. Which lens design would provide the best visual acuity for a patient with the following information? K's 42.00@ 180/ 42.50@90 Rx -6.75 +1.75 cx 90 A. Front surface toric rigid gas permeable B. Spherical rigid gas permeable C. Soft sphere D. Bitoric rigid gas permeable The answer is A. The wetting angle of a rigid gas permeable material describe


Documentinformatie

Geüpload op
16 januari 2024
Aantal pagina's
186
Geschreven in
2023/2024
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden
$15.99

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
KatelynWhitman
3.6
(259)
Verkocht
1242
Volgers
485
Items
43377
Laatst verkocht
18 uur geleden




Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen

Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.