Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Document preview thumbnail
Voorbeeld 2 van de 7 pagina's
Tentamen (uitwerkingen)

S12 sprinkler test Questions with Correct Answers| 2024 Update 100% Solved

Document preview thumbnail
Voorbeeld 2 van de 7 pagina's

S12 sprinkler test Questions with Correct Answers| 2024 Update 100% Solved fire department connection normally on exterior of building... FDNY can pump supplemental water into the sprinkler system, standpipe, or other system furnishing water for fire extinguishment to supplement existing water supplies. system control valve valve controlling flow to water-based fire protection systems. fire command center ... MFSPC ... MLP ... tags on closed section valves serving affected areas: area affected, brief description, occupancy classification, c of f number, estimated time until operational Green tag no impairment found in entire system- main control valve white tag fully out of service- place on all fire department connecitons

Voorbeeld van de inhoud

S12 sprinkler test Questions with Correct Answers| 2 024 Update 100% Solved fire department connection ✔✔ normally on exterior of building... FDNY can pump supplemental water into the sprinkler system, standpipe, or other system furnishing water for fire extinguishment to supplement existing water supplies. system control valve ✔✔ valve controlling flow to water -based fire protection systems. fire command center ✔✔ ... MFSPC✔✔ ... MLP✔✔ ... tags✔✔ on closed section valves serving affected areas: area affected, brief description, occupancy classification, c of f number, estimated time until operational Green tag ✔✔ no impairment found in entire system - main control valve white tag✔✔ fully out of service - place on all fire department connecitons red tag✔✔ place on main control valve if FULLY OR PARTIALLY out of service... put sprinkler company name, date of removal from service and anticipated time to operational blue disk✔✔ partially out of service - on all fire department connections water storage tank ✔✔ ... OS & Y valve ✔✔ indicating type of control valve used for fire sprinkler system deluge valve ✔✔ water supply control valve intended to be operated by actuation of an automatic detection system that is installed in the same area as the discharge devices. INTENDED USE IS MANUAL AND AUTO deluge sprinkler system ✔✔ employing open sprinklers that are attached to a piping system that is connected to a water supply through a valve that is opened by the operation of a detection system installed in the same areas as the sprinklers. WHEN IT OPENS, water flows into the piping system and discharges from all sprinklers attached. Early suppresion fast response sprinklers ✔✔ fast response sprinkler that is listed for its capability to provide fire suppression of specific high challenge fire hazards extra large orifice sprinklers ✔✔ = or > 1 inch less pressure to achieve a given discharge density extended coverage sprinkler ✔✔ 400 max square feet discharge fire pump ✔✔ a provider of liquid flow and pressure dedicated to fire protection. A fire pump is a part of a fire sprinklers system water supply and can be powered by electric, diesel or steam. connected to public water source or tank. provides higher pressure to spri nkler system Glass bulb sprinkler ✔✔ operated by heat breaking a glass bulb filled with a non freezing liquid with diameters that vary form 3 mm for quick response to 5 mm for standard response hose valve ✔✔ valve to additional hose connection hydraulic placard ✔✔ sign attached to a hydraulically calculated sprinkler system indicating the design density, required gallons per minute and pressure for the system to operate properly hydraulically calculated systems ✔✔ method of sizing auto sprinkler piping using a prescribed amount of water to be distributed over a specific area. impairment coordinator ✔✔ in charge of safety during out of service systems intermediate level sprinkler ✔✔ sprinkler equipped with integral shields to protect the operating elemtn form discharge from sprinklers installed at higher elevations large orifice sprinkler ✔✔ sprinkler head with orifice size equal or greater than 3/4 and less than 1 inch listed device ✔✔ A fire protection component that has been tested to perform under parameters specified for its use by a nationally recognized testing agency. Underwriter's Laboratory (UL) and Factory Mutual (FM) are the two most common. Master Pressure Reducing Valve ✔✔ A pressure reducing valve installed to regulate pressures in an entire fire protection system and/or standpipe system zone. Main Drain ✔✔ The primary drain connection located on the system riser and also utilized as a flow test connection. Microbiologically Influenced Corrosion (MIC) ✔✔ Corrosion caused by the presence of microbes in the water supply that over time attack the interior of metallic piping and cause leaks, pitting, and blockages.

Documentinformatie

Geüpload op
5 januari 2024
Aantal pagina's
7
Geschreven in
2023/2024
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden
$10.49

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
DrJon
3.8
(160)
Verkocht
586
Volgers
188
Items
21155
Laatst verkocht
1 maand geleden




Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen