• Wrong document? Swap it for free
  • Written by students who passed
  • Immediately available after payment
  • Read online or as PDF
Sell
Where do you study
Your language
Document preview thumbnail
Preview 4 out of 47 pages
Exam (elaborations)

Texas Fire Alarm Rules and Statutes Exam Questions & Answers Graded A+

Document preview thumbnail
Preview 4 out of 47 pages

Both audible and visual alarm indication shall be supervised - ANSWERTrue Speakers are permitted for voice communication only - ANSWERFalse Private Mode audible signal appliance minimum sound level of - ANSWER45 dBA at 10' -- 10 dBA above average, 5 dBA above maximum sound level; whatever is greater measured at 5' above floor. A signal indicating an emergency requiring immediate action is an - ANSWERalarm signal Where Public Mode audible appliances are installed they shall be ____________ above average ambient sound level - ANSWER15 dBA An alarm silencing switch, a means for silencing the trouble notification appliance shall be permitted only if _________ - ANSWERIt is key-operated or located within a local cabinet It will give a trouble signal if left in the "silence" position when no alarm exists It will transfer indication of an alarm to a visual indicator What is the sound made by one or more audible notification appliances such as bells or horns in response to the operation of an initiating device? - ANSWERAudible alarm Where audible appliances are installed in mechanical equipment rooms, the average ambient sound level is - ANSWER85 dBA Alarm sounding appliances are installed in mechanical equipment rooms, the average ambient sound level is? - ANSWER85 dBA Wall mounted audio/visible notification appliance must be at least 6' 8" above the floor but not more than ____________ above the floor - ANSWER96" Sleeping area where audible appliances are installed shall be ____________ above the average ambient sound level - ANSWER15 dBA The light appliance source color shall be clear or nominal white and shall not exceed - ANSWER1000 candela Where ceiling heights allow, wall mounted audible appliances shall have their tops above the finished floors at heights of not less than - ANSWER90" Wall mounted telephone where accessible to the general public, one telephone per location shall be no higher than - ANSWER48" Wall mounted visible notification appliance must be at least 6' 8" above the floor but not more than _______ above the floor - ANSWER96" The visible appliances shall be located no more than ____________ from the end of the corridor with separation no more than __________ between visible appliances - ANSWER15', 100' In a dwelling unit the detectors shall be wired in such a manner that actuation of one alarm will actuate _________ alarms - ANSWERAll Loud speakers shall have a mounting height of _____ or _____ below the ceiling - ANSWER90", 6" Household Audible alarms must produce a prevailing sound higher than ______ at 10' - ANSWER75 dBA Audible alarms may have a mounting heights of ____ or ____ below the ceiling - ANSWER90", 6" An average ambient sound level greater than ______ shall require the use of a visible notification appliance - ANSWER105 dBA Manual fire alarm boxes shall not be mounted less than 3-1/2' and not more than 5' above the finished floor - ANSWERFalse All fire detection devices shall be listed or approved for the purpose for which they are intended - ANSWERTrue A detector should not be recessed in any way unless they have been tested for such a mounting - ANSWERTrue Partitions which do not extend to the ceiling and are 18" or more from the ceiling are considered not to have an effective smoke travel to warrant a reduction of spacing - ANSWERFalse Smoke detectors listed or approved exclusively for door release service shall not be used for open area protection - ANSWERFalse Smoke detectors placed in areas used to handle environmental air, such as plenum ceiling, may be substitute for open area protection - ANSWERFalse Manual fire alarm boxes shall not be mounted less than 3-1/2' and not more than 4' above the finished floor - ANSWERTrue Smoke detector listed exclusively for door release shall be used for open air protection - ANSWERTrue Manual pull station shall be located as near as possible and not more than five feet from each exit - ANSWERTrue Detectors shall not be recessed in any way unless they have been tested and listed for such mounting - ANSWERTrue The detector sensitivity cannot be tested or measured using any spare device that administers an unmeasured concentration of aerosol into a detector - ANSWERTrue How far from the doorway shall a Manual fire alarm station be mounted - ANSWER5' or as close as AHJ says What kind of detectors are used for door closer operation - ANSWERPhotoelectric or Ionization When there is more than a _____ inch depth partition over a door or double-doors two detectors must be installed - ANSWER24 A bimetallic heat detector is an example of a - ANSWERSpot-type detector Vane type flow switch have no longer than _____ to initiate alarm - ANSWER1-1/2 minutes Smoke detector must be tested every - ANSWER1 year The principles of a smoke sensing fire detector are - ANSWERIonization, Photoelectric, and Projected beam Sensitivity in smoke detectors and single & multiple-station smoke alarms in other than 1&2 family dwellings shall be checked within _____ year or years after installation - ANSWER1 year Type of detector that should be installed six feet away from a florescent fixture - ANSWERPhotoelectric A spot-type heat detector located on a wall, shall not be more than _____ inches from the ceiling - ANSWER12 A type of smoke detector which uses a small amount of radioactive material is a - ANSWERIonization detector With a peak ceiling, heat and smoke detectors shall be located within _____ of the peak, measured horizontally - ANSWER3' A spot-type smoke detector located on a ceiling or, if on a sidewall, between the ceiling and _____ down from the ceiling to the top of the detector - ANSWER12" Flame detectors which respond to radiant energy outside the range of human vision are - ANSWERInfrared and Ultraviolet detectors Smoke detectors shall not be located - ANSWERNear air supply diffusers When beams project more than _____ inches below the ceiling and are more than 8' on center, each bay formed by the beams shall be treated as a separate area for heat detectors - ANSWER18 When manual fire alarm boxes are used, the distance between boxes will not be in excess of _____ - ANSWER200' A water flow device should be field adjusted so that an alarm is initiated in no more than _____ seconds - ANSWER90 Smoke detectors shall not be located directly in the air stream of _____ - ANSWERSupply registers Detectors shall not be installed until after - ANSWERFinal clean up of all trades A flow switch is a _____ type of device - ANSWEROn/Off A heat detector integrally mounted on a smoke detector shall be listed for approved for not less than ______ feet - ANSWER50 Detectors for common return systems should be installed up to ______ in front or behind openings - ANSWER12" Detectors listed for ducts shall be located _____ the last inlet or outlet upstream and the first inlet or outlet downstream of the damper - ANSWERBetween Smoke detector sensitivity shall be tested _____ - ANSWERWithin one year of installation and every other year thereafter A line-type obscuration smoke detector, where the light beam is projected across the area to be protected detector - ANSWERProjected beam smoke detector When manual fire alarm boxes are used, the distance between boxes will not be in excess of _____ feet - ANSWER200 A device which detects the visible or invisible particles of combustion is a _____ detector - ANSWERSmoke Manual fire alarm boxes shall not be less than _____ inches and not more than _____ inches above the floor level - ANSWER42 and 48 Single and multiple station smoke alarms shall be tested, after the initial installation test, every - ANSWERYear Fixed-temperature restorable bimetallic type heat detectors can be tested by what means? - ANSWERHair Dryer Smoke detectors have a radius of _____ feet - ANSWER15 When materials _____ react to simpler compounds _____ is produced - ANSWERExothermically, heat What are the three sides of a fire triangle - ANSWERFuel, ignition source, oxygen What type of detector is suited for an atrium location - ANSWERProjected beam A condition where a burning fuel produces smoke without flames is known as - ANSWERPyrolosis What kind of detector is most appropriate for an elevator lobby in an apartment building - ANSWERSpot-type According to the NFPA 90A, HVAC systems that deliver over _____ CFM genereally require _____ shutdown and _____ side smoke detection during a fire alarm situation - ANSWER2000, Fan, Supply side smoke detection Stair pressurization is an example of - ANSWERSmoke control Where a "1" indicates a single tap of a code wheel, a "" signal from a street box generates what box number at the public fire dispatch center - ANSWER3521 Street boxes transmit their unique coded number a minimum of _____ times - ANSWER3 The first public fire reporting system was installed in - ANSWERBoston A central station must have a minimum of _____ operators on duty at all times, and must have a minimum of _____ means of re-transmission - ANSWER2, 2 ______ fire alarm supervising stations only monitor accounts ______ - ANSWERProprietary, under the same ownership The primary means of communication for a DACT must be a - ANSWERLoop start telephone line A DACT requires a minimum of _____ means of communication between the protected premises and the fire alarm supervising station - ANSWER2 A DACT may take up to _____ seconds per dialing attempt - ANSWER90 The primary purpose of dwelling fire warning equipment is _____ - ANSWERLife safety Multiple-station smoke alarms for dwelling use cannot be _____ between individual dwelling units - ANSWERInterconnected The National Institute of Standards and Technology conducted test on smoke alarms in the _____ in the 1970's - ANSWERIndiana Dunes Heat detectors installed in an attic with a maximum ambient temperature of 120 degrees Fahrenheit must be designed and rated to operate at a minimum temperature of _____ degrees Fahrenheit - ANSWER145 Smoke detectors installed within _____ feet of a cooktop or range must be of the _____ type - ANSWER21, photo Dwelling smoke alarms must produce an audible _____ signal for at least _____ minutes - ANSWEREvacuation, 4 Rechargeable power supplies for smoke alarms must recharge in _____ hours or less when connected to a _____ portion of branch circuit - ANSWER4, switched Who is the responsible party to ensure that the fire alarm system is property inspected, tested, and maintained - ANSWERSystem Owner What is a reacceptance test - ANSWERA test that is conducted immediately after changes to a fire alarm system Non-restorable heat detectors are tested by - ANSWERLaboratory testing a sample What are the four things a contractor must provide at the time an owner accepts the fire alarm system - ANSWEROperation/maintenance manuals Record of completion Record of inspection and testing Site specific software How long must an owner retain records for a fire alarm system - ANSWERThe life of the system What is the basic method of trouble shooting an open on a fire alarm signaling line circuit - ANSWERUse software to determine what devices fail to report Improperly connected or grounded shields often result in - ANSWERErratic operation Ground faults are commonly caused by what three things - ANSWERConduit burs Improper insulation types Wet conduit Testing smoke detectors with a can of smoke is a _____ test - ANSWERFunctional A single open circuit on a Class A fire alarm circuit results in - ANSWERA trouble, but all devices/appliances operate Public fire reporting systems operate on a _____ mA DC loop - ANSWER50 What are three methods of preventing smoke migration - ANSWERFan shut down Smoke Exhaust Stair pressurization Central station service has _____ elements - ANSWER6 Smoke detectors must be installed within _____ feet of a door to a sleeping room - ANSWER21 Wall mounted heat detectors must be mounted between _____ and _____ inches from a ceiling - ANSWER4, 12


Document information

Uploaded on
November 23, 2023
Number of pages
47
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers
$18.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Exampool
3.9
(32)
Sold
225
Followers
148
Items
3570
Last sold
2 months ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions

Whoops! We can’t load your doc right now. Try again or contact support.