Florida Fire Inspector State Exam Review | Questions and Verified Answers | 100% Correct | 2023/ 2024 Update
Florida Fire Inspector State Exam Review | Questions and Verified Answers | 100% Correct | 2023/ 2024 Update Q: A live fire watch is needed if the fire alarm system is out of service for what length of time Answer: Four hours or more Q: What is a common type of indicating valve Answer: OS&Y: outside screw & yoke Q: What is the maximum travel distance to an exit in a sprinkler protected education building Answer: 200 feet Q: What type of electrical outlet should be installed in bathrooms Answer: GFCI: ground fault circuit interrupted Also anywhere water is within 6'6" in kitchens Q: The smallest diameter heavy timber can be is Answer: 8 inches Q: Is plate glass considered safety glass Answer: No Q: What is the common scale used for floor plans Answer: 1/4 inch equals one foot Q: Where in a wood working shop is a fire most likely to occur Answer: At the dust hogger: the machine that's turns wood scrap into chips or splinters Q: What is the most critical thing for an inspector to check in a warehouse Answer: The automatic sprinkler system Q: According to NFPA 1 what is a highly volatile liquid Answer: A liquid with a boiling point of less than 68 degrees F Q: What is fire resistance Answer: The ability for a structural assembly to maintain its load bearing ability under fire conditions Q: What is a beam Answer: A horizontal structure member used between posts, columns, or walls Q: What is the activation temperature of an orange head sprinkler Answer: 500 to 575 degrees F Classification is ultra high Q: The thickness of wood used for fire stopping is what Answer: No less than 2 inches Q: What are two types of automatic roof vent designs Answer: Fusible link type should not operate below 300 degrees F Drop out panel type Q: What is the maximum travel distance on a landing to reach the stairs Answer: 4 feet Q: Who has the ultimate authority to make changes in fire codes Answer: The AHJ Q: What are the hazards of dip tank operations Answer: Fire involving the liquids and explosions involving vapor and air mixtures Q: What is the hour rating of the roof in a dry cleaning facility Answer: Not less than one hour Q: What is the discharge size of the inspectors test connections Answer: The discharge orifice shall be equal in size to the smallest sprinkler in the system Q: Fire dampers are activated how Answer: By fusible links
Documentinformatie
- Geüpload op
- 10 november 2023
- Aantal pagina's
- 44
- Geschreven in
- 2023/2024
- Type
- Tentamen (uitwerkingen)
- Bevat
- Vragen en antwoorden