Residential Electrician Exam #2 questions with correct answers
The MAXIMUM height that kitchen countertop receptacle outlets may be installed above the countertop shall be _____. a) 12 inches b) 18 inches c) 20 inches d) 24 inches CORRECT ANSWER C: 20 inches Ref: 210.52(C)(5) For dwelling units, panelboards are permitted to be located in all the areas listed EXCEPT _____. a) hallways b) garages c) kitchens d) bathrooms CORRECT ANSWER D: bathrooms Ref: 240.24(E) The MAXIMUM number of grounded conductors allowed to be terminated in an individual terminal, if conductors are not paralled, in the neutral bus of a panelboard is _____. a) one b) two c) three d) four CORRECT ANSWER A: one Ref: 110.14(A)