ICC Bolting Exam 2023-2024


According to the IBC, the "blank" is to hire the special inspector. - ANSWER
owner or owners agent. 2009 IBC Section 1704.1

According to the IBC, the "blank" is the responsible for the approval of a person's
qualifications to act as a special inspector. - ANSWER code official. 2009 IBC,
Section 1704.1

According to the IBC, discrepancy corrections are made known to the building
official by: - ANSWER final report. 2009 IBC, Section1704.1.2

When is the code official to be made aware of a discrepancy found during a special
inspection? - ANSWER If it is not corrected by the contractor. 2009 IBC, Section
1704.1.2

According to the Model Program for Special Inspection, the special inspector is to
document work that is nonconforming: - ANSWER In a written report - Section II
B 4 - Model Programs

According to the Model Program for Special Inspection, the special inspector is to
prepare written report of inspection: - ANSWER After each inspection visit -
Section II B 5 - Model Programs

According to the Model Program for Special Inspection, which of the following
items does not need to be included in each inspection report? - ANSWER
Description of discussions with the contractor - Section B 5 - Model Programs

According to the Specification for Structural Joints using high strength bolts, the
nominal diameter of standard bolt holes shall be how much larger than the
nominal bolt diameter? - ANSWER 1/16 inch - Specification for Structural Joints
Table 3.1

Discrepancies in the work shall be brought to the immediate attention of the
"blank" for corrective action. - ANSWER the contractor - 2009 IBC, Section
1704.1.2.

The special inspector shall furnish inspection reports to the "blank" and to the
"blank"? - ANSWER Building Official and Registered Design professional

The special inspector shall provide continuos inspection of: - ANSWER
Single-pass fillet welds greater than 5/16 inch in size - 2099 IBC, Table 1704.3, Item

,5.3

The special inspections required by this code are not required where the work is
done on the premise of a? - ANSWER Approved fabricator - 2009 IBC, Section
1704.2.2

The special inspection of the steel fabrication process shall not be required where
the fabricator does not perform any? - ANSWER heating operations - 2009 IBC,
Section 1704.3, Exceptions # 1

According to the Specifications for Structural Steel Buildings, ASTM Standard
"blank" is to be used for the material test for steel sheets. - ANSWER A568 -
Section A31, Specifications for Structural Steel Buildings

According to the Specifications for Structural Steel Buildings, the "blank" conducts
the material tests for identification of the structural steel. - ANSWER Fabricator
or Testing Laboratory - Section A31, Specifications for Structural Steel Buildings.

According to the Specifications for Structural Steel Buildings, which of the
following steel members are allowed to be unidentified steel? - ANSWER
Unimportant members, where their physical properties and weldability would not
affect the structure strength - Section A31b, Specifications for Structural Steel
Buildings

According to the Code of Standard Practice for Steel Buildings and Bridges, how is
steel of special material to be identified? - ANSWER It is marked by the supplier -
Section 5.1.1, Code of Standard Practice for Steel Buildings and Bridges

According to the Code of Standard Practice for Steel Buildings and Bridges, how
are fabricators stock steel material identified? - ANSWER Certified mill test
reports - Section 5.2.2 - Code of Standard Practice for Steel Buildings and Bridges

According to the Specification for Structural Steel Buildings, what ASTM Standard
would apply to a sample for structural steel pipe? - ANSWER A53 - Section A31a -
Specification for Structural Steel Buildings

According to the Code of Standard Practice for Steel Buildings and Bridges, the
number of samples required to be tested for structural steel is: - ANSWER The
number specified by the ASTM specification - Section 5.1.1 - Code of Standard
Practice for Steel Buildings and Bridges



According to the Specification for Structural Steel Buildings, which ASTM standard

, would apply to a sample for structural steel plates? - ANSWER A36, A283, and
A242 - Section A31a - Specification for Structural Steel Buildings



According to the Specification for Structural Steel Buildings, "blank" tests are
required for samples for built-up sections consisting of plates over 2 inches in
thickness. - ANSWER Charpy V-notch testing - Section A31d, Specification for
Structural Steel Buildings



According to the Specification for Structural Steel Buildings, ASTM standard
"blank" would apply to a sample for structural steel bars. - ANSWER A36, A529,
and A572 - Specification for Structural Steel Buildings



Steel furnished for structural load-carrying purposes shall be properly : - ANSWER
Identified - 2009 IBC, Section 2203.1



Steel that is not readily identifiable as to grade by marking and test records shall
be: - ANSWER tested - 2009 IBC, Section 2203.1



Where materials or assemblies are required by this code to be labeled, such
material and assemblies shall be labeled by: - ANSWER An approved agency -
2009 IBC, Section 1703.5

Inspection of the steel frame for compliance with the approved construction
documents should verify: - ANSWER Member location, Bracing, and Stiffening -
2009 IBC, Section 1704.3.2.

Continuous inspection of bolt pre-tensioning is required when using: - ANSWER
The calibrated wrench method - 2009 IBC, Section 1704.3.3.3.

Where required by the code, the building owner shall employ a registered design
professional to perform: - ANSWER Structural Observation - 2009 IBC, Section
1709.1

According to the Specification for Structural Joints, how does the special inspector
verify the bolts, nuts, and washers meet the requirements of A325 or A490

Document information

Uploaded on
September 8, 2023
Number of pages
19
Written in
2023/2024
Type
Exam (elaborations)
Contains
Unknown
$14.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
luzlinkuz
3.8
(326)
Sold
1586
Followers
852
Items
31860
Last sold
2 days ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions