Lead Inspector study Guide Title X - Residential LEad-based Paint Hazard Reduction Act (1992) Lead Periodic Table - Atomic Number = 82; Weight = 207.19 Lead in Body - CNS, Brain, Kidney Common route of exposure - Lead-bearing dust EPA Reference Level in Blood - 5 micrograms/deciliter Health Treatment - Remove person from further exposure Medication - Chelation LBP Hazards - any condition that causes exposure to lead... Lead Based Paint - 1 microgram/cm2 OR 0.5% Clearance Levels - floor 40, sills 250, troughs 400 micrograms Construction PEL - 50 microgram/m3 8 hour TWA XRF Sources - 57 Cobalt; 109 Cadmium Dosimeters - Worn by inspectors using XRF XRF Leaks - 6 months surface wipe, radiation survey meter XRF Calibration Check - beginning, every four hours, end LBP Inspection - surface by surface investigation to determine the presence of lead-based paint and a report Multi-family home - 21+ units (1960 or older); 10+ units () Laboratory - National Lead Laboratory Accreditation Program Final Clearance Procedure - Hepa/Detergent/Hepa Soil limits - 400 micrograms/gram (play); 1200 micrograms/gram (other), 5000 micrograms/gram permanent abatement Sodium sulfide - Clear to black