Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 2 out of 9 pages
Exam (elaborations)

CRCST % with correct answers

Document preview thumbnail
Preview 2 out of 9 pages

CRCST % Low temp sterilization requirements - correct answer -Efficacy: has capability of providing minimum required sterility assurance level (SAL) -Safety: no toxic residuals remaining after cycle completion -Exposure monitoring: ability to monitor sterilization process to ensure concentrations of sterilants in the work area remain within any required exposure limits -Sterilization performance monitoring: monitored using physical, chemical, and biological indicators -Penetration: must be able to penetrate through packaging material -Material compatibility: no changes in device functionality after cycle -Adaptability: compatible with or easily modified to meet existing health care practices -Approval: cleared by appropriate regulatory agency Toxicity Standards for Low Temp sterilizers - correct answer Ethylene Oxide -OSHA PEL: 1.0 ppm -NIOSH IDLH Limit: 800 ppm Hydrogen Peroxide -OSHA PEL: 1.0 ppm -NIOSH IDLH Limit: 75 ppm Ozone -OSHA PEL: .1 ppm NIOSH IDLH Limit: 5 ppm Low temp sterilizer process used - correct answer EtO: inactivates microbes by a process called alkylation Hydrogen Peroxide & Ozone: destroy microbes through oxidation - chemicals that are gases at room temp are more effective penetrants b/c they will not cause condensation Oxidation - correct answer hydrogen peroxide gas plasma, vaporized hydrogen peroxide, and ozone use this. addition of oxygen to a compound with a loss of electrons. Ethylene oxide (EtO) Efficacy and Penetration - correct answer Efficacy: Alkylation process destroys cells ability to metabolize or reproduce Penetration: its a small molecule that vaporizes easily penetrate through material (plastic included) -High vapor pressure -Low boiling point EtO Cycle and Process - correct answer Preconditioning & Humidification Gas introduction Exposure Evacuation Air washes -must go through aeration cycle to remove residual EtO EtO Parameters and Safety - correct answer Gas concentration: 450-1200 mg/L Temp: 98-145 degrees Relative Humidity: 40-80% Exposure time: 1-6 Hours Aeration time: 8-12 hours at 122-140 degrees must be in room with air exchange 10 per hour, neg pressure room. EtO should not be used to sterilize... - correct answer -liquids: will combine with liquids and could produce harmful byproducts -devices with energy source: could spark in chamber -leather EtO Packaging and Performance measures - correct answer packaging: do not use aluminum foil, nylon films, polyester, pas films, and styrofoam performance measure: Physical Chem indicators Biological indicators- bacillus atrophaeus spores Hydrogen Peroxide Gas Plasma - correct answer -safer than EtO -faster turnaround time -byproducts from cycle non toxic H2O2 Gas Plasma efficacy and penetration - correct answer Efficacy: -use hydrogen peroxide solution ranging from 59-95% -destroys gram negative and gram positive vegetive bacteria Penetration -uses deep vacuums, multiple pulse additions of sterilant and increased concentration Phases of H2O2 gas plasma - correct answer Vacuum: load heats while vacuum system removes remaining water. Air is removed from chamber until pressure is reduced to below atmospheric pressure Injection: remeasured amount of concentration of hydrogen peroxide is pumped into vaporizer bowl Diffusion: drives H2O2 into small areas and lumens of device, chamber returns to atmospheric pressure to accomplish Plasma: vacuum decreases pressure, radio freq energy is radiated. RF energy ionizes H2O2 creating gas plasma Vent: air vented into chamber through bacterial high-efficiency particulate air filters process byproducts: oxygen and water H2O2 Gas plasma parameters and performance monitors - correct answer Time: 24-75 min Cycle temp: less than 131 degrees H2O2 concentration: 59-95% Performance monitors -physical: parameters are printed and recorded -Chemical: internal/external -Biological: geobacillus Stearothermophilus H2O2 Gas plasma not compatible with... - correct answer liquids and powders any materials that absorb liquid Items that contain cellulose Vaporized Hydrogen Peroxide (VHP) Efficacy and Penetration - correct answer Efficacy: uses 59% H2O2 solution Penetration: vaporized H2O2 injected 4 times, upon 4th load aerated VHP is exhausted from chamber through a catalytic converter that converts it into water and oxygen VHP cycle - correct answer Conditioning: remove air and moisture. chamber is evacuated then recharged with dry sterile air Leak test: Vacuum is held to ensure leak tight chamber Sterilization: enhance penetration by injecting H2O2 vapor into chamber 4 times Aeration: chamber exhausted through catalytic converter turning it into water and oxygen VHP Parameters and Packaging - correct answer cycle temp: less than 122 degrees H2O2 concentration: 59% Time: 28-55 min Packaging: polywrap, made 100% from polypropylene VHP Performance monitors - correct answer Physical: operate on fixed auto cycles controlled by microprocessor Chem: CI Biological: Geobazillus Stearothermophillus Ozone Sterilization (O3) Efficacy - correct answer Generate sterilants using medical grade oxygen and water O3 sterilizes by oxidizing proteins and enzymes causing death the organisms O3 Cycle - correct answer 4 1/2 Hour cycle 2 identical half cycles vacuum is dean followed by humidification phase, O3 is then injected into chamber. -O3 converted to oxygen at end Ozone Parameters - correct answer Cycle temp: 87.4 - 97 Degrees F O3 concentration: 59% Relative humidity: 85-100% Time: 4 1/2 hours Ozone Safety and packaging - correct answer Safety: bluish color, pungent odor - toxic gas odor threshold: .003-.01 ppm Packaging: woven fabric and metal foils are a NO GO Manual Disinfection Documentation - correct answer Date Test strip results expiration date items disinfected if scope name of tech who cleared it name of patient What can cause Chemical indicators to fail - correct answer utility or sterilizer malfunction bad loading techniques wrong cycle incorrect CI monitor poor storage of CIs Positive BI reasons - correct answer wrong BI or PCD Incorrect placement not following IFU Incorrect strange of BI incorrect cycle not loading cart to allow for airflow Validation - correct answer done by device manufacturer to obtain, record and interpret test results required to establish a process consistently producing sterile products -microbiological placed in hardest spots to reach with BI or Liquid suspension -subjected to 3 cycles at 1/2 exposures Verification - correct answer procedures ran by health care facility to confirm that the validation undertaken by manufacturer is applicable to specific setting Bowie-Dick Test - correct answer class II CI placed over chamber drain complete uniform color change = neg blotchy color change = positive


Document information

Uploaded on
August 9, 2023
Number of pages
9
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers
$12.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Sold
1
Followers
1
Items
259
Last sold
2 year ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions

Whoops! We can’t load your doc right now. Try again or contact support.