• Wrong document? Swap it for free
  • Written by students who passed
  • Immediately available after payment
  • Read online or as PDF
Sell
Where do you study
Your language
Document preview thumbnail
Preview 2 out of 12 pages
Exam (elaborations)

UST Certification Study Guide 2022/2023 Solved 100% Correct

Document preview thumbnail
Preview 2 out of 12 pages

When tanks arrive at the job site, how should they be unloaded? - ANSWER-Lifted off with a cable attached to the tank lifting lugs. As an alternative lifting method, should a cable or chain be wrapped around the tank? - ANSWER-No, Never. When you are lifting a tank, using the lifting lugs, which of these procedures should be followed? - ANSWER-Attach a triangle cable through the lugs, with not more than a 30-degree angle from the center line. After you unload a new tank on a clean, level surface at the job site, what else would you do prior to inspection and pretesting? - ANSWER-Chock the tank to prevent it from rolling. Which of the following items should be physically check for damage or imperfections at the job site? - ANSWER-- Piping (steel and fiberglass). - Fittings, vents, fill-boxes, anodes, etc. - The tanks themselves. Sti-P3 tanks are delivered with shipping plugs in tank openings. What should be done to these plugs prior to testing? - ANSWER-Remove the plugs and replace them with standard threaded plugs, properly doped. Should dielectric bushings be installed in all openings of a sti-P3 tank? - ANSWER-Yes. All openings. What is the maximum air pressure to which a steel tank should be subjected in a pre-installation test? - ANSWER-5 Pounds For fiberglass reinforced plastic (FPR) tanks, up to 12 feet in diameter, what is an acceptable air pressure to which the tanks may be subjected in a pre-installation test? - ANSWER-3 Pounds For FRP tanks over 12 feet in diameter, what is the maximum air pressure to which the tanks should be subjected in a pre-installation test? - ANSWER-3 Pounds When you are conducting an air test on a tank, the type of gauge that should be used is...? - ANSWER-A pressure gauge with a maximum limit of 10-15 psig. When conducting a pre-installation air test on a new single wall tank... - ANSWER-Soap the surface of the tank and observe any air bubbles in the soap.

Content preview

UST Certification Study Guide 2022/2023
Solved 100% Correct
When tanks arrive at the job site, how should they be unloaded? - ANSWER-Lifted off with a cable attached to the tank lifting lugs.
As an alternative lifting method, should a cable or chain be wrapped around the tank? - ANSWER-No, Never.
When you are lifting a tank, using the lifting lugs, which of these procedures should be followed? - ANSWER-Attach a triangle cable through the lugs, with not more than a 30-
degree angle from the center line.
After you unload a new tank on a clean, level surface at the job site, what else would you do prior to inspection and pretesting? - ANSWER-Chock the tank to prevent it from rolling.
Which of the following items should be physically check for damage or imperfections at the job site? - ANSWER-- Piping (steel and fiberglass).
- Fittings, vents, fill-boxes, anodes, etc.
- The tanks themselves.
Sti-P3 tanks are delivered with shipping plugs in tank openings. What should be done to
these plugs prior to testing? - ANSWER-Remove the plugs and replace them with standard threaded plugs, properly doped.
Should dielectric bushings be installed in all openings of a sti-P3 tank? - ANSWER-Yes.
All openings.
What is the maximum air pressure to which a steel tank should be subjected in a pre-
installation test? - ANSWER-5 Pounds
For fiberglass reinforced plastic (FPR) tanks, up to 12 feet in diameter, what is an acceptable air pressure to which the tanks may be subjected in a pre-installation test? - ANSWER-3 Pounds
For FRP tanks over 12 feet in diameter, what is the maximum air pressure to which the tanks should be subjected in a pre-installation test? - ANSWER-3 Pounds
When you are conducting an air test on a tank, the type of gauge that should be used is...? - ANSWER-A pressure gauge with a maximum limit of 10-15 psig.
When conducting a pre-installation air test on a new single wall tank... - ANSWER-Soap
the surface of the tank and observe any air bubbles in the soap. The proper procedure for conducting a pre-installation air test of a steel tank is to... - ANSWER-Apply 3 to 5 pounds of air pressure and soap all surfaces and weld seams visible through the coating, while inspecting for bubbles.
The proper procedure for conducting a pre-installation air test of an FRP tank, under 12 feet in diameter, is to... - ANSWER-Apply 3 pounds of air pressure and soap all surfaces, while inspecting for any sign of a leak, either audible or visible in the form of bubbles on the surface.
The proper procedure for conducting a pre-installation air test of a double-walled tank is to... - ANSWER-Pressurize the inner tank, monitor the pressure for 1 hour, and then pressurize the space between the inner and outer tanks with air from the inner tank.
When conducting a pre-installation air test on a double-walled tank, which of the following is correct? - ANSWER-Release pressure on the outer tank (interstice) first, then release the pressure on the inner tank, after the test is completed.
When shipped, a steel tank is covered with a coating that is an important part of the tank's corrosion prevention system. "Holidays" which show up in the coating at the installation site... - ANSWER-Should be touched up with a compatible coating, after proper surface preparation.
Touch up of "holidays" in steel tank coatings, at the installation site, should be done... - ANSWER-According to the manufacturer's instructions.
Dielectric bushings are usually made of... - ANSWER-Nonmetallic material.
Factors to consider in determining the size, shape, and depth of a tank excavation include... - ANSWER-- The tank manufacturer's recommendations.
- Requirements for compacting bedding and backfill, as well as stability of the soil.
- Depth of cover.
In the absence of local requirements, the recommended minimum distance between a tank excavation and adjacent structures or property lines is - ANSWER-5 feet.
Reinforcement of a steel underground tank may be required by the tank manufacturer if... - ANSWER-The burial depth is greater than the tank diameter.
According to FRP tank manufacturers' specifications, the burial depth for an FRP tank should not exceed... - ANSWER-7 feet.
Ballast, whether water or fuel, should be added to the tank at what stage of the installation? - ANSWER-After the tank has been backfilled to the top of the tank.

Document information

Uploaded on
July 20, 2023
Number of pages
12
Written in
2022/2023
Type
Exam (elaborations)
Contains
Questions & answers
$11.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
CLOUNDLite
4.0
(131)
Sold
665
Followers
389
Items
12381
Last sold
1 day ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions