Electrons from the photocathode are concentrated and directed toward the other end of the image-intensifier tube by a series of ________ and by ________ kVp applied through the tube. - CORRECT ANSWER 1) Electrostatic Lenses (Focusing Lenses) 2) 25 Once electrons are propelled across the tube from the photocathode, they strike the ________. - CORRECT ANSWER Output Phosphor Once the energy of the electrons hits the output phosphor, it is converted by the phosphor to ________ in amounts ________ to ________ times greater than the photocathode. - CORRECT ANSWER 1) Visible Light 2) 50 3) 75 The increase in brightness from the photocathode to the output phosphor is known as ________. - CORRECT ANSWER Flux Gain The ________ phosphor is smaller than the ________ phosphor, resulting in an increase in brightness known as ________. - CORRECT ANSWER 1) Output 2) Input 3) Minification Gain Total brightness gain is a product of ________ gain and ________ gain. - CORRECT ANSWER 1) Minification 2) Flux Total brightness gain ranges from ________ to ________, and decreases as the tube ages. - CORRECT ANSWER 1) 5000 2) 20000 A complete program in a radiology department that addresses all aspects of quality, including customer service, image interpretation, accuracy of diagnosis, and distribution of radiologists' reports is known as: - CORRECT ANSWER Quality Assurance A program that specifically addresses the safe and reliable operation of equipment is known as: - CORRECT ANSWER Quality Control A quality control program is required by ________. - CORRECT ANSWER The Joint Commission Collimation must be accurate to within ________% of the source-to-image receptor distance. - CORRECT ANSWER 2 The effective focal spot size should be within ________% of the size stated in the equipment specifications. - CORRECT ANSWER 50 kVp must be accurate to within ________% of the kVp indicated. - CORRECT ANSWER 10 The exposure timer should be accurate to within ________% of the time chosen for exposures over 10 ms. - CORRECT ANSWER 5 Adjacent mA stations should be accurate to within ________% of one another. This is known as ________. - CORRECT ANSWER 1) 10 2) Exposure Linearity Radiation intensity of sequential exposures should not vary more than ________%. This is known as ________. - CORRECT ANSWER 1) 5 2) Exposure Reproduceability

Content preview

ARRT Radiography Exam Review 2 l
Fully solved 2023
Electrons from the photocathode are concentrated and directed toward the other end
of the image-intensifier tube by a series of ________ and by ________ kVp applied
through the tube. - CORRECT ANSWER 1) Electrostatic Lenses (Focusing
Lenses)
2) 25
Once electrons are propelled across the tube from the photocathode, they strike the
________. - CORRECT ANSWER Output Phosphor
Once the energy of the electrons hits the output phosphor, it is converted by the
phosphor to ________ in amounts ________ to ________ times greater than the
photocathode. - CORRECT ANSWER 1) Visible Light
2) 50
3) 75
The increase in brightness from the photocathode to the output phosphor is known
as ________. - CORRECT ANSWER Flux Gain
The ________ phosphor is smaller than the ________ phosphor, resulting in an
increase in brightness known as ________. - CORRECT ANSWER 1) Output
2) Input
3) Minification Gain
Total brightness gain is a product of ________ gain and ________ gain. -
CORRECT ANSWER 1) Minification
2) Flux
Total brightness gain ranges from ________ to ________, and decreases as the
tube ages. - CORRECT ANSWER 1) 5000
2) 20000
A complete program in a radiology department that addresses all aspects of quality,
including customer service, image interpretation, accuracy of diagnosis, and
distribution of radiologists' reports is known as: - CORRECT ANSWER Quality
Assurance
A program that specifically addresses the safe and reliable operation of equipment is
known as: - CORRECT ANSWER Quality Control
A quality control program is required by ________. - CORRECT ANSWER The
Joint Commission
Collimation must be accurate to within ________% of the source-to-image receptor
distance. - CORRECT ANSWER 2
The effective focal spot size should be within ________% of the size stated in the
equipment specifications. - CORRECT ANSWER 50
kVp must be accurate to within ________% of the kVp indicated. - CORRECT
ANSWER 10
The exposure timer should be accurate to within ________% of the time chosen for
exposures over 10 ms. - CORRECT ANSWER 5
Adjacent mA stations should be accurate to within ________% of one another. This
is known as ________. - CORRECT ANSWER 1) 10
2) Exposure Linearity
Radiation intensity of sequential exposures should not vary more than ________%.
This is known as ________. - CORRECT ANSWER 1) 5
2) Exposure Reproduceability

, ARRT Radiography Exam Review 2 l
Fully solved 2023
The fluoroscopy exposure rate should be tested with a digital dosimeter, and should
not be more than________ per minute. - CORRECT ANSWER 100 mGyᵃ
CR plates should be erased at least every ________. - CORRECT ANSWER 48
Hours
CR readers should be calibrated ________. - CORRECT ANSWER Annually
________ comprises of systems for image acquisition, display, network and storage.
- CORRECT ANSWER Picture Archiving and Communications System (PACS)
________ is a standard protocol used for blending PACS and various imaging
modalities. - CORRECT ANSWER Digital Imaging and Communications in
Medicine (DICOM)
________ blends patient care information, reporting and billing. - CORRECT
ANSWER Hospital Information System (HIS)
________ is used for ordering procedures and reporting results. - CORRECT
ANSWER Radiology Information System (RIS)
________ is a comprehensive collection of patient information stored in a digital
format that may be shared across networks. Data may include history, medications,
allergies, test results and vital signs. - CORRECT ANSWER Electronic Medical
Record (EMR)
The sharpness of the structural edges recorded on the images is known as: -
CORRECT ANSWER Spacial Resolution
Spacial resolution may be described as the ________ representation of the part
being imaged. - CORRECT ANSWER Geometric
The highest spacial resolution that can be recorded, and is controlled by pixel pitch,
is known as: - CORRECT ANSWER Nyquist Frequency
The amount of radiation striking the image receptor is known as: - CORRECT
ANSWER Receptor Exposure
The measurement of the luminance of an area in a radiographic image displayed on
a monitor is known as: - CORRECT ANSWER Brightness
The visible difference between any two selected areas of brightness levels within the
displayed radiographic images is known as: - CORRECT ANSWER Contrast
The number of brightness levels (or shades of gray) visible on an image is linked to
the bit depth of a system, and is known as: - CORRECT ANSWER Grayscale
When slight differences between gray shades is present (low contrast) but the total
number of gray shades is great, it is known as: - CORRECT ANSWER Long
Scale Contrast
When considerable or major differences between gray shades are present (high
contrast), but the total number of gray shades is small, it is known as: - CORRECT
ANSWER Short Scale Contrast
Contrast resolution is controlled by ________, or the number of bits per pixel. -
CORRECT ANSWER Bit Depth
With larger the bit depth, ________ levels of gray are possible in an image. -
CORRECT ANSWER Greater
The range of exposures that may be captured by a detector is known as: -
CORRECT ANSWER Dynamic Range
The range of exposures that produce quality images at appropriate patient dose is
known as: - CORRECT ANSWER Exposure Latitude

Document information

Uploaded on
June 25, 2023
Number of pages
12
Written in
2022/2023
Type
Exam (elaborations)
Contains
Questions & answers
$5.89

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
claytondoc
4.2
(13)
Sold
77
Followers
11
Items
1329
Last sold
3 months ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions