• Wrong document? Swap it for free
  • Written by students who passed
  • Immediately available after payment
  • Read online or as PDF
Sell
Where do you study
Your language
Document preview thumbnail
Preview 2 out of 9 pages
Exam (elaborations)

MA oil burners test 2023 -solved

Document preview thumbnail
Preview 2 out of 9 pages

Air Heater. - Answer- . An indirect-fired appliance intended to supply heated air for space heating and other purposes, but not intended for permanent installation. Air pressure switch . - Answer- An electrical switch designed to prove that the proper draft has been established by the power venter or burner and allows the burner to operate. If the power venter or burner is not performing so as to satisfy the operating requirements of the equipment for safe performance, the switch will de-energize the burner control circuit preventing the burner from operating. Anti-flooding Device - Answer- . A primary safety control that causes the flow of fuel to be shut off upon a rise in fuel level or upon receiving excess fuel, and which operates before the hazardous discharge of fuel can occur Appliances; industrial - Answer- (a) Low-Heat Industrial Appliance. An industrial appliance such as a commercial cooking range, pressing machine boiler at any pressure, bake oven, candy furnace, stereotype furnace, drying and curing appliance, and other process appliances in which materials are heated or melted at temperatures (excluding flue-gas temperatures) not exceeding 600°F (316°C). Appliances otherwise classed as medium-heat appliances may be considered as low-heat appliances if not larger than 100 cubic feet (2.8 m 3 ) in size excluding any burner equipment and blower compartment (b) Medium-Heat Industrial Appliance - Answer- (b) An industrial appliance such as an annealing furnace (glass or metal), charcoal furnace, galvanizing furnace, gas producer, commercial or industrial incinerator, and steam boiler operating at over 50 psig (345 kPa) pressure when such appliance is larger than 100 cubic feet (2.8 m 3 ) in size, and other furnaces classified as medium-heat appliances in accordance with recognized good practice c) High-Heat Industrial Appliance. - Answer- c. An industrial appliance such as billet and bloom furnace, blast furnace, brass melter, cupola, glass furnace, open-hearth furnace, and ceramic kiln and vitreous enamelizing oven (ferrous metals) when such appliances are larger than 100 cubic feet (2.8 m 3 ) in size, and other furnaces classified as high-heat appliances in accordance with recognized good practice Application Permit/Certificate of Completion. - Answer- A standard form issued for use in all jurisdictions throughout the Commonwealth Approved - Answer- . Unless otherwise indicated, listed or approved by a nationally recognized testing laboratory Authority Having Jurisdiction. - Answer- . The state fire marshal or his designee Boiler. - Answer- . A closed vessel in which water is heated, steam is generated, steam is superheated, or any combination thereof, by the application of heat from combustible fuels in a self-contained or attached furnace. Boiler, High Pressure). - Answer- . A boiler for generating steam at pressures in excess of 15 psi (103 kPa), or for heating water to a temperature in excess of 250°F (121°C) or at a pressure in excess of 160 psi (1103 kPa). Boiler, Hot Water Supply. - Answer- A low-pressure hot water boiler having a volume exceeding 120 gallons (454 L), or a heat input exceeding 200,000 Btu per hour (58.6 kw) or an operating temperature exceeding 200°F (93°C) that provides hot water to be used externally to itself. Boiler, Low Pressure - Answer- A boiler for generating steam at pressures not in excess of 15 psig (103 kPa) or for furnishing water at a temperature not in excess of 250°F (121°C) at pressures not in excess of 160 psig (1103 kPa). Burner, Automatically Ignited - Answer- A burner equipped so that main burner fuel may be turned on and ignited automatically Burner, Manually Ignited. - Answer- . A burner equipped so that main burner fuel is turned on only by hand and ignited under supervision. Burner, Mechanical Draft Type. - Answer- A burner that includes a power-driven fan, blower, or other mechanism as the primary means for supplying the air for combustion. Burner, Natural Draft Type. - Answer- A burner that depends primarily upon the natural draft created in the chimney or venting system to induce the air required for combustion into the burner. Central Heating Appliance. - Answer- stationary heating appliance comprising the following classifications: boilers, central furnaces, floor furnaces, and wall furnaces. A floor-mounted unit heater to be connected to a duct system is classified also as a central heating appliance Centralized Oil Distribution System. - Answer- A system of piping through which oil is supplied from a separate central supply tank or tanks to more than one building, mobile home, recreational vehicle, or other structure. Certificate of Completion - Answer- A standard form issued for use in all jurisdictions throughout the Commonwealth. Chimney Connector.. - Answer- . The pipe that connects a fuel-burning appliance to a chimney. Clearance.. - Answer- The distance between a heat-producing appliance, chimney, chimney connector, vent, vent connector, or plenum, and other surfaces. Combustible Material. - Answer- Material made of or surfaced with wood, compressed paper, plant fibers, plastics, or other material that will ignite and burn, whether flame-proofed or not, or whether plastered or unplastered. Confined Space. - Answer- Confined Space. Any space whose volume is less than 50 cubic feet per 1,000 Btu/hr (4.8m 3 per kw) of the aggregate input rating of all fuel-burning appliances installed therein. Constant-Level Valve. - Answer- A device for maintaining within a reservoir a constant level of oil fuel for delivery to an oil burner. Control, Limit. - Answer- An automatic safety control responsive to changes in fluid flow or level, pressure, or temperature, and which is normally set beyond the operating range for limiting the operation of the controlled equipment by shutting off the energy supply. Control, Primary Safety (Combustion Safeguard) - Answer- A safety control responsive directly to flame properties, sensing the presence or absence of flame and, in the event of ignition failure or unintentional flame extinguishment, causing safety shutdown Control, Safety. - Answer- Control, Safety. Automatic controls (including relays, switches, and other auxiliary equipment used in conjunction therewith to form a safety-control system) that are intended to prevent unsafe operation of the controlled equipment. Cooking Appliance, Floor-Mounted Restaurant-type. . - Answer- A range, oven, broiler, or other miscellaneous cooking appliance of type designated for use in hotel and restaurant kitchens and for mounting on the floor Damper. - Answer- . A valve or plate for controlling draft or the flow of gases including air. Direct-Fired Appliance. - Answer- A fuel-burning appliance in which the products of combustion (flue gases) are mixed with the medium (e.g., air) being heated. Direct Vent Appliance.. - Answer- A system consisting of an appliance, combustion air and flue gas connections between the appliance and the outside atmosphere, and a vent cap supplied by the manufacturer, and constructed so that all air for combustion is obtained from the outside atmosphere and all flue gases are discharged to the outside atmosphere. Draft Booster. - Answer- . A power operated fan, blower, or other device installed in the chimney connector to increase the natural draft developed in the connected chimney. Draft Regulator, Barometric. - Answer- . A device built into a fuel-burning appliance or made a part of a chimney connector or vent connector, which functions to reduce excessive draft through an appliance to a desired value by admitting ambient air into the appliance chimney, chimney connector, vent or vent connector. Fire Wall.. - Answer- Fire Wall. See 780 CMR: Massachusetts State Building Code. Flue Collar. - Answer- That portion of an appliance designed for attachment of a chimney or vent connector or a draft hood. Fuel Oil. - Answer- Any oil as specified by the American Society for Testing and Materials (ASTM) standard D396-90, Standard Specification for Fuel Oils; or ASTM D6751-02, Standard Specification of Biodiesel Fuel (B100) Blend Stock for Distillate Fuels Furnace, Central Warm-Air. - Answer- A self-contained indirect-fired or electrically heated appliance designed to supply heated air through ducts to spaces remote from or adjacent to the appliance location. (a) Gravity-type Central Furnace. - Answer- A central furnace depending primarily on circulation of air by gravity. (b) Gravity-type Central Furnace with Integral Fan. - Answer- . A central furnace equipped with a fan as an integral part of its construction and operable on gravity systems only. The fan is used only to overcome the internal resistance to air flow. (c) Gravity-type Central Furnace with Booster Fan. - Answer- . A central furnace equipped with a booster fan that does not materially restrict free circulation of air by gravity flow when such a fan is not in operation. (d) Forced-Air-type Central Furnace.. - Answer- . A central fur


Document information

Uploaded on
May 29, 2023
Number of pages
9
Written in
2022/2023
Type
Exam (elaborations)
Contains
Questions & answers
$10.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Gordones22
4.1
(108)
Sold
508
Followers
351
Items
9500
Last sold
5 days ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions

Whoops! We can’t load your doc right now. Try again or contact support.