FDNYC G60 Practice Exam Answers Correct Updated
FDNYC G60 Practice Exam Answers Correct Updated All torch operators, an oxigen-fuel torch using any amount of oxigen and flamable gas and fire guards must have a current - ANS Certificate of Fitness The Certificate of Fitness holder - ANS must regulate the pressure and flow of oxygen and natural gas to each torch. if the torch operator for jewelry manufacture involves - ANS any oxygen with any fuel gas containers, the operator must be a C of F holder. A Certificate of Fitness Holder must keep his or her certificate - ANS on their person or otherwise readily available for inspection by any representative of the fire Department The easiest way to extinguish a fire caused by a leak is to - ANS close the shutoff valve Permits issued by the FDNY are required to conduct the following hot work: - ANS storing, using or handling oxygen and a flammable gas, storing, using or handling any flammable gas (e.g. LPG or CNG or acetylene) in excess of 400 SCF. Storing, using or handling any oxidizing gas (e.g. oxygen) in excess of 504 SCF. For LPG, 400 SCF is - ANS approximately 47 lbs the number of LPG containers for the storage, use, handling or transportation, requiring a permit - ANS 14.1 oz = 54 cont. 16.4 oz = 46 cont. 20 lbs = 3 cont. 33.5 lbs = 2 cont. 40 lbs = 2 cont. 100 lbs = 1 cont. Portable LPG containers that are more than 16.4 oz and CNG containers with a capacity greater than 8.7 SCF - ANS must NOT stored, handled, or used indoors in the following occupancies (as defined in the Building code): residential occupancies, factory and industrial occupancies; educational occupancies; institutional occupancies, except as the commissioner may authorize by rule. Site-specific permit - ANS may be a permanent permit or a temporary permit. Permanent permits are valid for 12 months only A city-wide permit is valid - ANS up to 30 days Permits shall be - ANS readily available on the premise for inspection by Fire Department representatives. Hot work authorization should be issued by the responsible person, and it - ANS must be available for inspection by any representative of the department during the performance of the work, and for 48 hours after the work is complete
Connected book
Written for
- Institution
-
Lehman College
- Module
-
FDNYC G60
Document information
- Uploaded on
- April 30, 2023
- Number of pages
- 11
- Written in
- 2022/2023
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
- fdnyc g60 practice exam
- fdnyc g60
- a certificate of fit
-
fdnyc g60 practice exam answers correct updated
-
fdny certificate of fitness g60 torch use of flammable gases
-
the certificate of fitness holder