2023
In a preaction sprinkler system, what must happen before water will flow?
Select one:
A. The alarm condition must persist for a set time
B. An alarm initiating device must be activated
C. The dry-pipe valve must close
D. System water pressure must drop - ANSWER-B. An alarm initiating device must be activated
Where is a main sprinkler system valve usually installed?
Select one:
A. On the main riser, below the water supply control valve
B. Outside the building, coming up out of the ground on a post
C. Near the FDC
D. On the main riser, above the water supply control valve - ANSWER-D. On the main riser, above the
water supply control valve
Which class of standpipe is intended for fire department use only?
Select one:
A. III
B. II
C. I
D. IV - ANSWER-C. I
Which is a distinguishing feature of old-style sprinkler heads?
Select one:
A. All heads are of the pendant type
,B. Only a few activation temperatures are available
C. The heads are highly sensitive to pressure fluctuation
D. The discharge pattern directs some water onto the ceiling - ANSWER-D. The discharge pattern directs
some water onto the ceiling
Which is a function of a sprinkler head?
Select one:
A. Detect smoke or fumes
B. Activate the fire alarm system
C. Report any trouble in the system
D. Auto-restore when the fire is out - ANSWER-B. Activate the fire alarm system
Which is a typical temperature rating for a sprinkler head in a light-hazard occupancy such as an office
building?
Select one:
A. 225°F (107°C)
B. 205°F (96°C)
C. 185°F (85°C)
D. 165°F (74°C) - ANSWER-D. 165°F (74°C)
Which is the preferred water source for a sprinkler system?
Select one:
A. An elevated storage tank
B. A private fire protection supply system
C. A municipal water system
D. A dedicated static supply - ANSWER-C. A municipal water system
Which sprinkler head mechanism uses a liquid-filled glass capsule to hold the cap in place?
Select one:
,A. Liquid capsule
B. Frangible bulb
C. Chemical pellet
D. Fusible device - ANSWER-B. Frangible bulb
Which type of facility monitors alarms systems located at multiple facilities?
Select one:
A. Protected premises control center
B. Central station
C. Remote alarm receiving center
D. Supervising alarm center - ANSWER-B. Central station
Which type of fire alarm annunciation system identifies the zone in which the alarm was initiated audible
or visual signals?
Select one:
A. Individual
B. Addressable
C. Coded
D. Master - ANSWER-C. Coded
A fire department pumper can supplement a sprinkler system water supply through the:
Select one:
A. Class I standpipe.
B. APV.
C. FDC.
D. OS&Y. - ANSWER-C. FDC.
According to NFPA 72, which type of alarm is caused by improper installation of an alarm system?
Select one:
, A. Trouble
B. Nuisance
C. False
D. Unwanted - ANSWER-B. Nuisance
According to NFPA 72, which type of alarm occurs when an activation of a fire alarm is not the result of a
potentially hazardous condition?
Select one:
A. Trouble
B. Tamper
C. False
D. Nuisance - ANSWER-D. Nuisance
According to the NFPA, a smoke alarm should be replaced after _____ years from the date of
manufacture
Select one:
A. 3
B. 7
C. 5
D. 10 - ANSWER-D. 10
All of the following are standard sprinkler head mounting positions except one. Choose the exception.
Select one:
A. Sidewall
B. Branch
C. Pendent
D. Upright - ANSWER-B. Branch
Closing the __________ valve is a method of shutting down the flow of water in a sprinkler system.