Rédigé par des étudiants ayant réussi Disponible immédiatement après paiement Lire en ligne ou en PDF Mauvais document ? Échangez-le gratuitement 4,6 TrustPilot
logo-home
Examen

NCLE Advanced Certification Exam

Note
-
Vendu
1
Pages
129
Grade
A+
Publié le
23-07-2022
Écrit en
2021/2022

The answer is D. The posterior optical zone will directly affect the lens to cornea relationship of a rigid gas permeable lens. If the posterior optical zone is steepened, it will increase the sagittal depth. If it is flattened, it will decrease the sagittal depth. Changing the power, which is accomplished by changing the anterior optical zone, will not affect the sagittal depth of the lens, nor will changing its edge design. - ANSWER 1. The sagittal depth of a rigid gas permeable contact lens can be altered without changing the diameter by: A. Changing the power B. Changing the edge design C. Changing the radius of curvature of the anterior optical zone D. Changing the radius of curvature of the posterior optical zone The answer is A. A lens is truncated by removing a segment of the lower edge of a contact lens. This creates a straight edge that interacts with the lower lid and aids in lens positioning. Of the lens designs listed in the question, the only one that requires precise positioning of its optical portions is a translating bifocal lens. - ANSWER 2. A truncation is used on a rigid gas permeable contact lens to help enhance the performance of which type of design? A. Bifocal B. Aphakic C. Bitoric D. Keratoconus The answer is B. A lenticular or myoflange design will decrease the mass of an aphakic lens as well as increase the edge profile, which allows it to interact more with the upper lid and aid in positioning of the lens. - ANSWER 3. The mass of an aphakic rigid gas permeable contact lens can be reduced by making the lens design: A. Spherical B. Lenticular C. Tricurve D. Aspheric The answer is B. Increasing the optical zone diameter and increasing the overall lens diameter will both tighten and steepen the relationship of the lens to the cornea. Decreasing the optic zone diameter will serve to flatten and loosen the lens to cornea relationship. Using a prism-ballasted lens design will not affect the lens to cornea relationship as it relates to sagittal depth. - ANSWER 4. In order to tighten the fit of a rigid gas permeable lens you can: I. Increase the optical zone diameter 2. Decrease the optical zone diameter 3. Increase the overall lens diameter 4. Use a prism ballasted lens design A. 3 only B. 1&3 C. 2 only D. 2&3 The answer is D. A hyperflange will decrease edge thickness as well as lens awareness . Aspheric peripheral curves change the posterior design of the lens but do not reduce edge thickness. A higher Dk material will not change the overall lens edge thickness. A myoflange will actually add thickness to the lens edge and is used for high plus lenses not high minus lenses. - ANSWER 5. A high minus rigid gas permeable lens will be thin centrally with relatively thick edges. To reduce the edge thickness, and increase overall comfort, use: A. Aspheric peripheral curves B. A myoflange C. A higher Dk material D. A hyperflange The answer is C. One would rarely polish or attempt to manipulate the central posterior surface of a rigid lens. Applying polishing pressure to the mid-peripheral and the peripheral anterior surface would add plus power. Applying polishing pressure to the central anterior surface would add minus power. - ANSWER 6. To add minus power to a rigid contact lens with a rotating modifying spindle, one would: A. Polish the posterior surface of the rigid lens B. Polish the mid peripheral anterior surface C. Polish the central anterior surface D. Polish the peripheral anterior surface The answer is A. The keratometer readings indicate the need for a spherical back surface, which would rule out the use of a bitoric lens. A soft spherical lens would not correct the moderate amount of refractive astigmatism that is present, nor would the spherical rigid gas permeable lens. A front surface toric RGP would best meet this patient's needs since it has a spherical back surface, but has a toric front surface which would correct the residual astigmatism. - ANSWER 7. Which lens design would provide the best visual acuity for a patient with the following information? K's 42.00@ 180/ 42.50@90 Rx -6.75 +1.75 cx 90 A. Front surface toric rigid gas permeable B. Spherical rigid gas permeable C. Soft sphere D. Bitoric rigid gas permeable The answer is A. The wetting angle of a rigid gas permeable material describes how a fluid spreads over the surface. It is important to remember, however, that wetting angle is a description of the material outside of the patient's natural ocular environment. Within minutes of insertion, a rigid lens is encapsulated in the natural tear mucin and the wetting angle of the material is no longer important. - ANSWER 8. Which of the following describes the angle that the edge of a bead of water makes with the surface of a plastic? A. Wetting angle B. Surface angle C. Bead angle D. Reflection angle The answer is B.

Montrer plus Lire moins
Établissement
NCLE Advanced Certification
Cours
NCLE Advanced Certification











Oups ! Impossible de charger votre document. Réessayez ou contactez le support.

École, étude et sujet

Établissement
NCLE Advanced Certification
Cours
NCLE Advanced Certification

Infos sur le Document

Publié le
23 juillet 2022
Nombre de pages
129
Écrit en
2021/2022
Type
Examen
Contient
Questions et réponses

Sujets

$13.49
Accéder à l'intégralité du document:

Mauvais document ? Échangez-le gratuitement Dans les 14 jours suivant votre achat et avant le téléchargement, vous pouvez choisir un autre document. Vous pouvez simplement dépenser le montant à nouveau.
Rédigé par des étudiants ayant réussi
Disponible immédiatement après paiement
Lire en ligne ou en PDF

Faites connaissance avec le vendeur

Seller avatar
Les scores de réputation sont basés sur le nombre de documents qu'un vendeur a vendus contre paiement ainsi que sur les avis qu'il a reçu pour ces documents. Il y a trois niveaux: Bronze, Argent et Or. Plus la réputation est bonne, plus vous pouvez faire confiance sur la qualité du travail des vendeurs.
LUCKYSTAR2022 West Virginia University
Voir profil
S'abonner Vous devez être connecté afin de suivre les étudiants ou les cours
Vendu
912
Membre depuis
4 année
Nombre de followers
724
Documents
9627
Dernière vente
4 jours de cela
LUCKYSTAR2022

Hi there well come to luckystar2022. Here you will find guaranteed quality solution for Nursing and any other Accademic related notes, exams, study guides, cases and many more. 100% value for your time and money. GOOD LUCK

3.5

156 revues

5
62
4
26
3
25
2
8
1
35

Documents populaires

Récemment consulté par vous

Pourquoi les étudiants choisissent Stuvia

Créé par d'autres étudiants, vérifié par les avis

Une qualité sur laquelle compter : rédigé par des étudiants qui ont réussi et évalué par d'autres qui ont utilisé ce document.

Le document ne convient pas ? Choisis un autre document

Aucun souci ! Tu peux sélectionner directement un autre document qui correspond mieux à ce que tu cherches.

Paye comme tu veux, apprends aussitôt

Aucun abonnement, aucun engagement. Paye selon tes habitudes par carte de crédit et télécharge ton document PDF instantanément.

Student with book image

“Acheté, téléchargé et réussi. C'est aussi simple que ça.”

Alisha Student

Foire aux questions