Accuracy vs. Precision
- These help us understand our measement
- Accuracy: How close a measurement or attempt is to the actual or target value
- Precision: How consistent our result are regardless of proximity to the actual or
target
- Comparison:
+ Accuracy is measuring near true value
+ Precision is getting consistent results
- It’s important that measuring devices are accurate and precise, if not result can be
misleading and fatal

Direct vs. Indirect Meserments
- Both types of measurements are routinely used in science
- Direct measuments: this is measuring the thing you are actually measuring
+ Example: FInding the thickness of a leaf with calipers
+ Counting the number of cells in a culture with a haemocytometer
- Indirect measurment: this is measuring something by measuring something else.
+ Example: Determing the number of cells in a solution by counting the number
of colonies in a dibute overnight culture
+ Determing the concentration of a solution by measuring the
absorbance of its metabolite

Pipetting
- Gilson Micropipette usage:
+ Use with plastic tip to transfer 0.2 microliters to 1000 microliters or 1 mililiter
+ Different pipette have a label on top indicates the maximum volume transfer
- P2: 0.2 - 2 microliters
- P20: 2- 20
- P200: 20- 200
- P1000: 200-1000
+ Setting volume:
- P2: (for ex: 152 means 1.52 micrliters)
- P20: ( for ex: 152 means 15.2 )
- P200: ( 152 means 152)
- P1000 ( 052 means 520) the 100= 1000 microliters which is the
maximum of the setting volume
- Setting volume:
+ Pipette tip:
- P20 and P200 use the same yellow tips
- P1000 use the larger white tips
+ Pipette volume:
- P20 set at 2 microliters require less push than the P20 set at 20
+ Common tip to avoid:
- Never use the pipette without the tip as the liquid should never enter the body
of pipette

, - Do not use the pipette that pass the volume maximum
- if the tip is falling down use the new one
- Eppendorf pipetting: has 3 stops




Principles of Spectrophotometry:
Absorbance
- Absorption Spectroscopy: using light to probe matter. Look for how a sample
absorbs light of a particular wavelength which related to concentration
+ In experiment, we look for a wavelength that is absorbed by a specific
sample. The light has an incoming power (P in). High power light or high
intensity light will have a lot of photons coming in. We also have a solution
with high concentration that can absorb the light, therefore, the P out is small.
+ A lot of photons get absorbed through the sample-> absorption spectroscopy
+ The ratio bwt the input power and output power related to sample
concentration
- Percent transmittance (%T): percentage of light that gets transmitted through our
sample = P out/ P in
- The spectrometry that can measure the output and input light intensity.
- Absorbance (A): linear related to the concentration. Does not have a unit. A= 2-
log(%T)= log(1/T)
- The transmittance and absorbance is inverslly related. 100% absorbance we will get
0% transmittance.
- Do different experiments by absorbance spectrum to know which suitable
wavelength. We scan through a lot of wavelengths. If a solution is blue, the red is
absorbed. FInd the lambda max.




Principles of Spectrophotometry: How
does a Spectronic 20 work?
- Energy source-> monochromator (prism to separate the different colour of light) to
select the wavelength -> get absorbed through the sample -> hit the detector.
- Turn the knob in the nanometer for the visible light to control the wavelength of light
the sample is exposed to
- The phototube in the detector is coated with photoemisive that can measure the light
intensity
- How to operate Spec 20 to generate an ansorption spectra of a dye called DCPIP:
+ A basic spectrophotometer with analog dials and manual setting of 0%
transmittance and blanking
+ The Specs 20s accept glass test tubes in the sample chamber (requires a
high volume of sample) about 3mL volume. Can ửok for one sample at a time

École, étude et sujet

Établissement
Cours
Cours

Infos sur le Document

Publié le
21 mars 2022
Nombre de pages
7
Écrit en
2021/2022
Type
Notes de cours
Professeur(s)
Dr. michelle belton
Contenu
Biology 2290 instrumental unit

Sujets

$15.99
Accéder à l'intégralité du document:

Mauvais document ? Échangez-le gratuitement Dans les 14 jours suivant votre achat et avant le téléchargement, vous pouvez choisir un autre document. Vous pouvez simplement dépenser le montant à nouveau.
Rédigé par des étudiants ayant réussi
Disponible immédiatement après paiement
Lire en ligne ou en PDF

Faites connaissance avec le vendeur
Seller avatar
xunthonguynlu

Faites connaissance avec le vendeur

Seller avatar
xunthonguynlu Western University Ontario
S'abonner Vous devez être connecté afin de pouvoir suivre les étudiants ou les formations
Vendu
1
Membre depuis
4 année
Nombre de followers
1
Documents
4
Dernière vente
4 année de cela

0.0

0 revues

5
0
4
0
3
0
2
0
1
0

Documents populaires

Récemment consulté par vous

Pourquoi les étudiants choisissent Stuvia

Créé par d'autres étudiants, vérifié par les avis

Une qualité sur laquelle compter : rédigé par des étudiants qui ont réussi et évalué par d'autres qui ont utilisé ce document.

Le document ne convient pas ? Choisis un autre document

Aucun souci ! Tu peux sélectionner directement un autre document qui correspond mieux à ce que tu cherches.

Paye comme tu veux, apprends aussitôt

Aucun abonnement, aucun engagement. Paye selon tes habitudes par carte de crédit et télécharge ton document PDF instantanément.

Student with book image

“Acheté, téléchargé et réussi. C'est aussi simple que ça.”

Alisha Student

Foire aux questions