• Wrong document? Swap it for free
  • Written by students who passed
  • Immediately available after payment
  • Read online or as PDF
Sell
Where do you study
Your language
Document preview thumbnail
Preview 2 out of 9 pages
Exam (elaborations)

Backflow Prevention Questions Study Material - Test-Ready Solutions Pack

Document preview thumbnail
Preview 2 out of 9 pages

Backflow Prevention Questions Study Material - Test-Ready Solutions Pack Drinking water standards in the United States were first established by the: - answer - Public Health Service Sanitary surveys must be conducted by community water supplies every ________ years - answer - 3 years The AWWA's manual of recommended practice about backflow prevention was first established in: - answer - 1966 The USEPA's Total Coliform Rule contains requirements for: - answer - Cross-connection surveys At the federal regulartory level, cross-connection control is not a: - answer - Funded mandate Under federal law, citizens can sue a water supplier if the quality does not meet: - answer - Federal Standards Utilities are responsible for the water's quality to the last: - answer - Free-flowing tap In 1925, the AWWA determined that_______ were not adequate protection: - answer - check valves A federal court can assess a civil penalty for maintaining a hazardous connection of up to $____ per day. - answer - $15,000 In 1898, a water utility was fined $_____ for supplying poor water. - answer - $5,000 A pump discharge generating 43 psig (297kPa) will result in a water column height of: - answer - 100 ft. (30.5m) (43x2.31 = 99.33) At sea level, the maximum vacuum possible is _____psig (kPa). - answer - 33.9 (234) For backsiphonage to occur in a piping system, the system must experience a: - answer - Pressure below atmospheric pressure A fluid's velocity increase results in a(n): - answer - Reduction in pressure To stop a siphon in a potable water system, one must: - answer - Admit air into the system For fluid to flow, there must be a path and a(n): - answer - Difference in pressure Absolute pressure consists of: - answer - Atmospheric + gauge pressure Negative gauge pressure may result from: - answer - High usage With an equal vacuum applied, a fluid lighter than water will produce a column elevation: - answer - Higher than water The base of a water column 20 feet high will produce a pressure of ______ psig (kPa). - answer - 8.7 (60) (20x .433 = 8.66 or 8.7) The Uniform Plumbing Code states that a direct connection between the potable water piping and sewer connected waste shall: - answer - Not be allowed under any condition According to the Uniform Plumbing Code backflow prevention assembles shall be tested: - answer - All of the above (repaired, installed, relocated) According to the Uniform Plumbing Code, vacuum breakers for hose connections in health care or laboratory areas should be not less than: - answer - 72 inches above the floor The backflow preventer not allowed on an irrigation system is a(n): - answer - Double check valve assembly A flushometer vacuum breaker must be installed above the fixture a minimum of _____ inches (cm). - answer - 6 (15) According to the Uniform Plumbing Code, in building where potable water and nonpotable water systems are installed, each system shall be: - answer - Clearly labeled The Uniform Plumbing Code requires backflow preventers to be tested by a: - answer - Certified backflow tester The critical installation level for a water closet ball cock is ________ inch(es) (cm). - answer - 1 (2.5) A backflow preventer may not be located in an area containing: - answer - Toxic Fumes The Uniform Plumbing Code color code for potable water pipe labels is: - answer - Green with white lettering A single check valve does not provide: - answer - Backflow protection A hose bibb vacuum breaker contains a: - answer - Spring-loaded check valve Flush tanks contain a specialized type of: - answer - Atmospheric vacuum breaker A dual check valve provides protection against: - answer - Elevated downstream pressure and negative supply pressure When a backflow preventer is installed as containment protection on a water service it is recommended that the plumbing system contain: - answer - Expansion tank A dual check valve is not: - answer - in-line testable An application for a dual check with an i


Document information

Uploaded on
November 3, 2026
Number of pages
9
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
$13.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Sold
10
Followers
0
Items
5251
Last sold
2 days ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions

Whoops! We can’t load your doc right now. Try again or contact support.