SECTION 1: PLANS EXAMINER ROLE, RESPONSIBILITIES & PROFESSIONAL
PRACTICE
1. The primary responsibility of a Plans Examiner I is to:
A) Design building systems
B) Review construction plans for compliance with applicable codes and standards
C) Perform field inspections
D) Issue building permits
Answer: B
Rationale: The Plans Examiner I reviews construction plans, specifications, and
calculations to ensure compliance with adopted codes before permits are issued.
2. A Plans Examiner I must be familiar with:
A) International Building Code (IBC)
B) International Fire Code (IFC)
C) NFPA standards
D) All of the above
Answer: D
Rationale: Plans examiners must know the IBC, IFC, NFPA standards, and local/Texas-
specific amendments.
3. When reviewing plans, the Plans Examiner I should review:
A) Only architectural drawings
B) All relevant disciplines (architectural, structural, mechanical, electrical, plumbing, fire
protection)
C) Only fire protection systems
D) Only site plans
Answer: B
,Rationale: Comprehensive review evaluates all building systems affecting fire and life
safety.
4. A Plans Examiner I must maintain:
A) Records of plan reviews and approvals
B) Personal notes only
C) Verbal approvals only
D) No documentation
Answer: A
Rationale: Written records of reviews and approvals are required for accountability and
legal defensibility.
5. The International Fire Code (IFC) primarily exists to:
A) Regulate building aesthetics
B) Provide minimum fire safety and life safety requirements
C) Determine structural loads
D) Eliminate NFPA standards
Answer: B
Rationale: The IFC establishes minimum requirements for fire prevention and life safety.
6. When multiple codes apply to a project, which requirement governs?
A) The least restrictive
B) The most restrictive
C) The oldest code
D) The code chosen by the contractor
Answer: B
Rationale: The most restrictive requirement ensures maximum safety.
7. The Plans Examiner’s role in the permitting process is to:
A) Approve permits without review
B) Verify code compliance before permit issuance
C) Design the building
D) Perform construction inspections
Answer: B
Rationale: The examiner verifies compliance before permit issuance; design and field
inspection are separate functions.
,8. A Plans Examiner should remain professionally impartial by:
A) Applying codes consistently regardless of owner or designer
B) Approving plans from preferred contractors
C) Waiving requirements on request
D) Avoiding documentation of deficiencies
Answer: A
Rationale: Impartial, consistent application of adopted codes is an ethical and
professional obligation.
9. When a plan review reveals a deficiency, the examiner should:
A) Approve the plan with a verbal warning
B) Document the deficiency clearly and require correction
C) Ignore minor deficiencies
D) Redesign the project personally
Answer: B
Rationale: Deficiencies must be identified, documented, and reported per jurisdiction
policy.
10. Plan review documentation should be:
A) Informal and vague
B) Clear, objective, and traceable
C) Verbal only
D) Limited to the examiner’s opinion
Answer: B
Rationale: Documentation must be clear, objective, and traceable to support
enforcement and legal defensibility.
11. The Plans Examiner I should verify that construction documents are:
A) Drawn to scale and sufficiently clear to show compliance
B) Signed by the owner only
C) Written in pencil
D) Limited to one sheet
Answer: A
Rationale: Construction documents must be of sufficient clarity to indicate the location,
nature, and extent of work and show code compliance.
, 12. Construction documents for fire protection and life safety systems must be
submitted:
A) After installation
B) Before system installation for review and approval
C) Only if the owner requests review
D) After the certificate of occupancy is issued
Answer: B
Rationale: Fire protection and life safety system documents must be reviewed and
approved prior to installation.
13. The Fire Code Official may waive submission of construction documents when:
A) The owner requests a waiver
B) The nature of the work is such that review is not necessary to obtain compliance
C) The contractor is experienced
D) The project is small
Answer: B
Rationale: Waiver is authorized only where review is not necessary to obtain compliance
with the code.
14. A Plans Examiner I should be able to research code requirements using:
A) Only personal memory
B) Nationally recognized codes, standards, and technical references
C) Social media
D) Contractor opinions
Answer: B
Rationale: The JPRs require the ability to research codes, standards, and technical
information.
15. When communicating plan review findings, the examiner should:
A) Use technical jargon to impress the applicant
B) Communicate clearly in writing and orally
C) Avoid explaining the code basis
D) Refuse to discuss findings
Answer: B
Rationale: The JPRs require oral and written communication skills to convey findings and
code basis.